Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > 2-Furanmethanamine

2-Furanmethanamine

2-Furanmethanamine structure

2-Furanmethanamine 

structure
  • CAS No:

    617-89-0

  • Formula:

    C5H7NO

  • Chemical Name:

    2-Furanmethanamine

  • Synonyms:

    2-Furanmethanamine;Furfurylamine;2-Furanmethylamine;2-(Aminomethyl)furan;2-Furfurylamine;α-Furfurylamine;(2-Furylmethyl)amine;(2-Furanylmethyl)amine;2-Furylmethanamine;NSC 49136;NSC 61168;(Furan-2-yl)methanamine;1-(2-Furanyl)methanamine;Furan-2-ylmethylamine;1057722-37-8

  • Categories:

    Pharmaceutical Intermediates  >  Bulk Drug Intermediates

Description

Colorless to light yellow liqui


Furfurylamine appears as a colorless liquid. About the same density as water. Used as a corrosion inhibitor and to make soldering flux.|Liquid


Furfurylamine appears as a colorless liquid. About the same density as water. Used as a corrosion inhibitor and to make soldering flux.

2-Furanmethanamine Basic Attributes

97.117

97.12

210-536-9

86GAN59F7R

61168|49136

2526

DTXSID6052295

2932190090

Characteristics

39.2

0.25

Furfurylamine appears as a colorless liquid. About the same density as water. Used as a corrosion inhibitor and to make soldering flux.

1.0533 g/cm3 @ Temp: 20 °C

−70 °C(lit.)

145.5 °C

99° F (NFPA, 2010)

1.497

H2O: soluble

Keep Cold

4 mm Hg ( 20 °C)

3.35 (vs air)

LD50 orally in Rabbit: 200 - 2000 mg/kg LD50 dermal Rat 100 mg/kg

Highly flammable. Soluble in water.

Amines, Phosphines, and Pyridines

Highly Flammable

Amines, such as FURFURYLAMINE, are chemical bases. They neutralize acids to form salts plus water. These acid-base reactions are exothermic. The amount of heat that is evolved per mole of amine in a neutralization is largely independent of the strength of the amine as a base. Amines may be incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides. Flammable gaseous hydrogen is generated by amines in combination with strong reducing agents, such as hydrides.

Safety Information

III

3

UN 2526 3/PG 3

3

R10;R20/21/22;R34

S26-S36/37/39-S45-S23-S16

LU9275000

C:Corrosive;

Absorbs carbon dioxide from the air.

P280-P305 + P351 + P338-P310

H226-H302 + H312-H314

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Flammable/combustible material. May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. (ERG, 2016)|Flammable - 3rd degree

|Danger|H226 (100%): Flammable liquid and vapor [Warning Flammable liquids]|P210, P233, P240, P241, P242, P243, P260, P261, P262, P264, P270, P271, P280, P301+P310, P301+P312, P301+P330+P331, P302+P350, P302+P352, P303+P361+P353, P304+P312, P304+P340, P305+P351+P338, P310, P312, P321, P322, P330, P361, P363, P370+P378, P403+P235, P405, and P501|Aggregated GHS information provided by 89 companies from 10 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Some of these materials may react violently with water. SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal; do not scatter the material. Do not get water inside containers. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Fully encapsulating, vapor-protective clothing should be worn for spills and leaks with no fire. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb with earth, sand or other non-combustible material and transfer to containers (except for Hydrazine). Use clean, non-sparking tools to collect absorbed material. LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)

Drug Information

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: May cause toxic effects if inhaled or ingested/swallowed. Contact with substance may cause severe burns to skin and eyes. Fire will produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or suffocation. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

furfurylamine

2-Furanmethanamine Use and Manufacturing

Uses

2-Furfurylamine is used in the synthesis of 2-Amino-N-(2-furylmethyl)propanamide, as a novel alanylglycine equivalent synthesized by bacilysin synthetase.


Intermediates

Pharmaceutical and medicine manufacturing|2-Furanmethanamine: ACTIVE

Fire Hazards -> Flammable - 3rd degree

Computed Properties

Molecular Weight:97.12
XLogP3:0.4
Hydrogen Bond Donor Count:1
Hydrogen Bond Acceptor Count:2
Rotatable Bond Count:1
Exact Mass:97.052763847
Monoisotopic Mass:97.052763847
Topological Polar Surface Area:39.2
Heavy Atom Count:7
Complexity:56
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of 2-Furanmethanamine

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.