Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > N-Methylpiperidine

N-Methylpiperidine

N-Methylpiperidine structure

N-Methylpiperidine 

structure

Description

CLEAR COLOURLESS LIQUID


1-methylpiperidine appears as a colorless liquid with the odor of pepper. May irritate skin and eyes. Vapors heavier than air. Used as a solvent and to make other chemicals.


1-methylpiperidine appears as a colorless liquid with the odor of pepper. May irritate skin and eyes. Vapors heavier than air. Used as a solvent and to make other chemicals.

N-Methylpiperidine Basic Attributes

99.17410

99.17

210-959-9

617374QZN4

2399

DTXSID8060822

29333999

Characteristics

3.24000

1.04000

1-methylpiperidine appears as a colorless liquid with the odor of pepper. May irritate skin and eyes. Vapors heavier than air. Used as a solvent and to make other chemicals.

0.8142 g/cm3 @ Temp: 23 °C

106-107 °C

107 °C

38 °F

n20/D 1.438

miscible

-20ºC

19.36 mmHg

LD50 intraperitoneal in mouse: 400mg/kg

3.46e-05 atm-m3/mole

Highly flammable. Soluble in water.

Amines, Phosphines, and Pyridines

Highly Flammable

1-METHYLPIPERIDINE neutralizes acids in exothermic reactions to form salts plus water. May be incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides. Flammable gaseous hydrogen may be generated in combination with strong reducing agents, such as hydrides.

Safety Information

II

3

UN 3286 3/PG 2

3

R11;R20/22;R34

S7-S16-S26-S36/37/39-S45-S9-S33

TN1225000

F:Flammable;C:Corrosive;

Stable under normal temperatures and pressures.

P210-P280-P305 + P351 + P338-P310

H225-H314

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Flammable/combustible material. May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. (ERG, 2016)|Flammable - 3rd degree

|Danger|H225 (100%): Highly Flammable liquid and vapor [Danger Flammable liquids]|P210, P233, P240, P241, P242, P243, P260, P261, P264, P270, P271, P273, P280, P301+P310, P301+P312, P301+P330+P331, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P310, P311, P312, P321, P322, P330, P361, P363, P370+P378, P403+P233, P403+P235, P405, and P501|Aggregated GHS information provided by 256 companies from 7 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.|H225: Highly Flammable liquid and vapor [Danger Flammable liquids]|P210, P233, P240, P241, P242, P243, P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P370+P378, P403+P235, P405, and P501

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Some of these materials may react violently with water. SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal; do not scatter the material. Do not get water inside containers. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Fully encapsulating, vapor-protective clothing should be worn for spills and leaks with no fire. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb with earth, sand or other non-combustible material and transfer to containers (except for Hydrazine). Use clean, non-sparking tools to collect absorbed material. LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)

Toxicity

4.47

Drug Information

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: May cause toxic effects if inhaled or ingested/swallowed. Contact with substance may cause severe burns to skin and eyes. Fire will produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or suffocation. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

1-methylpiperidine

N-Methylpiperidine Use and Manufacturing

Uses

Reactant for: ·sp3 C-H Bond activation with ruthenium(II) catalysts and C(3)-alkylation of cyclic amines ·One-pot synthesis of Z-cinnamic acids Reactant for synthesis of: ·Unsymmetrical ureas ·Antibacterial imidazolium, pyrrolidinium, and piperidinium salts ·C1-C16 segment of goniodomin A via palladium-catalyzed organostannane thioester coupling ·Multi-targeted inhibitors of insulin-like growth factor-1 receptor and members of ErbB-family receptor kinases

Piperidine, 1-methyl-: ACTIVE

Fire Hazards -> Flammable - 3rd degree

Computed Properties

Molecular Weight:99.17
XLogP3:1.3
Hydrogen Bond Acceptor Count:1
Exact Mass:99.104799419
Monoisotopic Mass:99.104799419
Topological Polar Surface Area:3.2
Heavy Atom Count:7
Complexity:46.1
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of N-Methylpiperidine

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.