Isobutyl hexanoate

Isobutyl hexanoate structure

Isobutyl hexanoate 

structure
  • CAS No:

    105-79-3

  • Formula:

    C10H20O2

  • Chemical Name:

    Isobutyl hexanoate

  • Synonyms:

    Hexanoic acid,2-methylpropyl ester;Hexanoic acid,isobutyl ester;Isobutyl caproate;Isobutyl hexanoate;2-Methylpropyl hexanoate

  • Categories:

    Cosmetic Ingredient  >  Perfuming

Description

ISOBUTYL CAPROATE is a liquid. Insoluble in water and less dense than water. Contact may irritate skin, eyes and mucous membranes. May be toxic by ingestion, inhalation or skin absorption. Used to make other chemicals.


Isobutyl caproate appears as a liquid. Insoluble in water and less dense than water. Contact may irritate skin, eyes and mucous membranes. May be toxic by ingestion, inhalation or skin absorption. Used to make other chemicals.|clear, colourless to yellowish liquid with a fruity, cocoa odour


Isobutyl caproate appears as a liquid. Insoluble in water and less dense than water. Contact may irritate skin, eyes and mucous membranes. May be toxic by ingestion, inhalation or skin absorption. Used to make other chemicals.|Isobutyl hexanoate is a hexanoate ester resulting from the formal condensation of hexanoic acid (caproic acid) with isobutanol. It has a role as a metabolite. It derives from an isobutanol.

Isobutyl hexanoate Basic Attributes

172.26

172.26

203-332-6

2A3X4W9GZ0

1993

DTXSID0059322

2915900090

Characteristics

26.30000

3.71

Isobutyl caproate appears as a liquid. Insoluble in water and less dense than water. Contact may irritate skin, eyes and mucous membranes. May be toxic by ingestion, inhalation or skin absorption. Used to make other chemicals.

0.9±0.1 g/cm3

348-350 °C(lit.)

169 °F

1.421

1 ml in 2 ml 80% alcohol (in ethanol)

Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.

0.413mmHg at 25°C

Insoluble in water.

Esters, Sulfate Esters, Phosphate Esters, Thiophosphate Esters, and Borate Esters

ISOBUTYL CAPROATE is an ester. Esters react with acids to liberate heat along with alcohols and acids. Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products. Heat is also generated by the interaction of esters with caustic solutions. Flammable hydrogen is generated by mixing esters with alkali metals and hydrides.

Safety Information

1993

2

36/37

26

MO8389000

Xi

P305 + P351 + P338

H315-H319

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. Substance may be transported hot. For hybrid vehicles, ERG Guide 147 (lithium ion batteries) or ERG Guide 138 (sodium batteries) should also be consulted. If molten aluminum is involved, refer to ERG Guide 169. (ERG, 2016)

|Warning|H315 (97.5%): Causes skin irritation [Warning Skin corrosion/irritation]|P264, P280, P302+P352, P305+P351+P338, P321, P332+P313, P337+P313, and P362|Aggregated GHS information provided by 186 companies from 3 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: CAUTION: All these products have a very low flash point: Use of water spray when fighting fire may be inefficient. CAUTION: For mixtures containing alcohol or polar solvent, alcohol-resistant foam may be more effective. SMALL FIRE: Dry chemical, CO2, water spray or regular foam. LARGE FIRE: Water spray, fog or regular foam. Do not use straight streams. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions. LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet). FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material. LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2016)

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing will only provide limited protection. (ERG, 2016)

Drug Information

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: Inhalation or contact with material may irritate or burn skin and eyes. Fire may produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or suffocation. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)

Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. Wash skin with soap and water. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. Keep victim calm and warm. (ERG, 2016)

Isobutyl hexanoate Use and Manufacturing

Methods of Manufacturing

It is obtained by direct esterification of caproic acid and isobutanol.

Uses

GB 2760-97 stipulates the permitted food spices. Mainly used to prepare apple, raw pear, jackfruit, candied fruit, ice cream, tropical fruits and cocoa flavors.

Hexanoic acid, 2-methylpropyl ester: ACTIVE

Food additives -> Flavoring Agents|Flavoring Agents -> JECFA Flavorings Index|Fatty Acyls [FA] -> Fatty esters [FA07] -> Wax monoesters [FA0701]

Flavoring Agents

Computed Properties

Molecular Weight:172.26
XLogP3:3.4
Hydrogen Bond Acceptor Count:2
Rotatable Bond Count:7
Exact Mass:172.146329876
Monoisotopic Mass:172.146329876
Topological Polar Surface Area:26.3
Heavy Atom Count:12
Complexity:119
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Material

Recommended Suppliers of Isobutyl hexanoate

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.