Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > Acetyl iodide

Acetyl iodide

Acetyl iodide structure

Acetyl iodide 

structure
  • CAS No:

    507-02-8

  • Formula:

    C2H3IO

  • Chemical Name:

    Acetyl iodide

  • Synonyms:

    Acetyl iodide

Description

ACETYL IODIDE is a colorless, fuming liquid with a pungent odor. Soluble in benzene and ether (Merck 11th ed., 1989). Vapors are irritating to the eyes and mucous membranes. Vapor causes pulmonary edema. Corrosive to metals and skin.


Acetyl iodide appears as a colorless, fuming liquid with a pungent odor. Soluble in benzene and ether (Merck 11th ed., 1989). Vapors are irritating to the eyes and mucous membranes. Vapor causes pulmonary edema. Corrosive to metals and skin.


Acetyl iodide appears as a colorless, fuming liquid with a pungent odor. Soluble in benzene and ether (Merck 11th ed., 1989). Vapors are irritating to the eyes and mucous membranes. Vapor causes pulmonary edema. Corrosive to metals and skin.

Acetyl iodide Basic Attributes

169.95

169.95

208-062-2

JAL3KV9I1O

1898

DTXSID0060141

2915900090

Characteristics

17.1

0.96790

Acetyl iodide appears as a colorless, fuming liquid with a pungent odor. Soluble in benzene and ether (Merck 11th ed., 1989). Vapors are irritating to the eyes and mucous membranes. Vapor causes pulmonary edema. Corrosive to metals and skin.

2.193g/cm3

108 °C

17.6ºC

1.539

32.44 mmHg

Flammable; reacts with water or ethanol to emit toxic iodide gas

Fumes in air. Turns brown on exposure to air as it reacts exothermically with moisture in the air to give hydrogen Iodide (hydroiodic acid), a strong irritant. Decomposes in water to give acidic products. Based on a scenario where the chemical is spilled into an excess of water (at least 5 fold excess of water), half of the maximum theoretical yield of Hydrogen Iodide gas will be created in 0.02 minutes. Experimental details are in the following: "Development of the Table of Initial Isolation and Protective Distances for the 2008 Emergency Response Guidebook", ANL/DIS-09-2, D.F. Brown, H.M. Hartmann, W.A. Freeman, and W.D. Haney, Argonne National Laboratory, Argonne, Illinois, June 2009.

Acyl Halides, Sulfonyl Halides, and Chloroformates

Water-Reactive

ACETYL IODIDE decomposes exothermically in water or alcohol. Reacts vigorously and exothermically with bases. May react vigorously or explosively if mixed with diisopropyl ether or other ethers in the presence of trace amounts of metal salts [J. Haz. Mat., 1981, 4, 291].

Safety Information

II

8

1898

34

26-36/37/39

The warehouse is ventilated, low-temperature and dry; stored separately from oxidants.

P210, P233, P234, P240, P241, P242, P243, P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P370+P378, P390, P403+P235, P404, P405, P501

H225

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Combustible material: may burn but does not ignite readily. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapors may travel to source of ignition and flash back. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Note: Most foams will react with the material and release corrosive/toxic gases. SMALL FIRE: CO2, dry chemical, dry sand, alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam. FOR CHLOROSILANES, DO NOT USE WATER; use AFFF alcohol-resistant medium-expansion foam. Move containers from fire area if you can do it without risk. Use water spray or fog; do not use straight streams. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 1898 datasheet. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. FOR CHLOROSILANES, use AFFF alcohol-resistant medium-expansion foam to reduce vapors. DO NOT GET WATER on spilled substance or inside containers. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas. SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)

Drug Information

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death. Contact with molten substance may cause severe burns to skin and eyes. Reaction with water or moist air will release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)|Corrosives

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

Acetyl iodide Use and Manufacturing

Acetyl iodide: ACTIVE

Health Hazards -> Corrosives

Computed Properties

Molecular Weight:169.95
XLogP3:0.8
Hydrogen Bond Acceptor Count:1
Exact Mass:169.92286
Monoisotopic Mass:169.92286
Topological Polar Surface Area:17.1
Heavy Atom Count:4
Complexity:33
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.