Product
Supplier
Encyclopedia
Inquiry
Home > Chemical CAS No.7 > Propyne SDS

Propyne Safety Data Sheets

SAFETY DATA SHEETS

According to the UN GHS revision 8

Version: 1.0

Creation Date: July 15, 2019

Revision Date: July 15, 2019

SECTION 1: Identification

1.1 GHS Product identifier

Product name

Propyne

1.2 Other means of identification

Product number

-

Other names

prop-1-yne; Propyne; Propine

1.3 Recommended use of the chemical and restrictions on use

Identified uses

Intermediates

Uses advised against

no data available

1.4 Supplier's details

Company

Echemi.com

Address

Echemi.com

Telephone

Echemi.com

1.5 Emergency phone number

Emergency phone number

Echemi.com

Service hours

Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

SECTION 2: Hazard identification

2.1 Classification of the substance or mixture

Flammable gases, Category 1A, Flammable gas

Gases under pressure: Liquefied gas

Specific target organ toxicity – single exposure, Category 3

2.2 GHS label elements, including precautionary statements

Pictogram(s)
Signal word

Danger

Hazard statement(s)

H220 Extremely flammable gas

H280 Contains gas under pressure; may explode if heated

H335 May cause respiratory irritation

Precautionary statement(s)
Prevention

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.

P271 Use only outdoors or in a well-ventilated area.

Response

P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.

P381 In case of leakage, eliminate all ignition sources.

P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P319 Get medical help if you feel unwell.

Storage

P403 Store in a well-ventilated place.

P410+P403 Protect from sunlight. Store in a well-ventilated place.

P403+P233 Store in a well-ventilated place. Keep container tightly closed.

P405 Store locked up.

Disposal

P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.

2.3 Other hazards which do not result in classification

no data available

SECTION 3: Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
Propyne Propyne 74-99-7 200-828-4 100%

SECTION 4: First-aid measures

4.1 Description of necessary first-aid measures

If inhaled

Fresh air, rest. Artificial respiration may be needed. Refer for medical attention. See Notes.

Following skin contact

ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.

Following eye contact

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

Following ingestion

Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.

4.2 Most important symptoms/effects, acute and delayed

Exposure Routes: inhalation, skin and/or eye contact (liquid) Symptoms: Irritation respiratory system; tremor, hyperexcitability, anesthesia; liquid: frostbite Target Organs: respiratory system, central nervous system (NIOSH, 2016)

4.3 Indication of immediate medical attention and special treatment needed, if necessary

FIRST AID: Inhalation--Fresh air, rest. Artificial respiration if indicated. Refer for medical attention ... Skin--ON FROSTBITE: rinse with plenty of water, do NOT remove clothes. Eyes--First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.

SECTION 5: Fire-fighting measures

5.1 Suitable extinguishing media

Shut off supply; if not possible and no risk to surroundings, let the fire burn itself out; in other cases extinguish with water spray ... Keep cylinder cool by spraying with water. Combat fire from a sheltered position.

5.2 Specific hazards arising from the chemical

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]: EXTREMELY FLAMMABLE. Will be easily ignited by heat, sparks or flames. Will form explosive mixtures with air. Vapors from liquefied gas are initially heavier than air and spread along ground. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966) and Methane (UN1971) are lighter than air and will rise. Hydrogen and Deuterium fires are difficult to detect since they burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.) Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2016)

5.3 Special protective actions for fire-fighters

Shut off supply; if not possible and no risk to surroundings, let the fire burn itself out. In other cases extinguish with water spray. In case of fire: keep cylinder cool by spraying with water. Combat fire from a sheltered position.

SECTION 6: Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Evacuate danger area! Personal protection: chemical protection suit including self-contained breathing apparatus. Ventilation. Remove all ignition sources. NEVER direct water jet on liquid.

6.2 Environmental precautions

Evacuate danger area! Personal protection: chemical protection suit including self-contained breathing apparatus. Ventilation. Remove all ignition sources. NEVER direct water jet on liquid.

6.3 Methods and materials for containment and cleaning up

Evacuate danger area! Ventilation. Remove all ignition sources. NEVER direct water jet on liquid. (Extra personal protection: chemical protection suit including self-contained breathing apparatus).

SECTION 7: Handling and storage

7.1 Precautions for safe handling

NO open flames, NO sparks and NO smoking. Closed system, ventilation, explosion-proof electrical equipment and lighting. Prevent build-up of electrostatic charges (e.g., by grounding) if in liquid state. Use non-sparking handtools. Prevent build-up of electrostatic charges (e.g., by grounding). Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

7.2 Conditions for safe storage, including any incompatibilities

Fireproof. Cool.Fireproof. Cool.

SECTION 8: Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

TLV: 1000 ppm as TWA

Biological limit values

no data available

8.2 Appropriate engineering controls

Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Wear face shield.

Skin protection

Cold-insulating gloves.

Respiratory protection

Use local exhaust or breathing protection.

Thermal hazards

no data available

SECTION 9: Physical and chemical properties and safety characteristics

Physical state

1-propyne is a colorless liquefied gas with a sweet odor. mp: -104°C, bp: -23.1°C. Insoluble in water, soluble in ethanol, chloroform and benzene. Moderately toxic by inhalation. Used as a specialty fuel. Denser than air. Vapors may ignite at distant sources of ignition and flash back.

Colour

Colorless gas [Note: Shipped as a liquefied compressed gas].

Odour

Sweet odor

Melting point/freezing point

360°C(lit.)

Boiling point or initial boiling point and boiling range

113°C(lit.)

Flammability

Flammable Gas

Lower and upper explosion limit/flammability limit

Lower flammable limit: 1.7% by volume

Flash point

35°C(lit.)

Auto-ignition temperature

no data available

Decomposition temperature

no data available

pH

no data available

Kinematic viscosity

gas at 298 deg K: 8.4X10-3 mPa-s; liquid at 233 deg K: 0.26 mPa-s

Solubility

Insoluble (NIOSH, 2016)

Partition coefficient n-octanol/water

log Kow = 0.94

Vapour pressure

204.6 mm Hg ( −49.5 °C)

Density and/or relative density

0.648 g/cm3

Relative vapour density

1.4 (AIR= 1)

Particle characteristics

no data available

SECTION 10: Stability and reactivity

10.1 Reactivity

1700 ppm [Based on 10% of the lower explosion limit for safety considerations even though the relevant toxicological data indicated that irreversible health efects or impairment of escape existed only at higher concentrations.]

Decomposes on heating and increasing pressure. This generates fire and explosion hazard.

10.2 Chemical stability

no data available

10.3 Possibility of hazardous reactions

Dangerous, when exposed to heat or flameThe gas is heavier than air and may travel along the ground; distant ignition possible. As a result of flow, agitation, etc., electrostatic charges can be generated.1-PROPYNE is highly flammable. The liquid material in cylinders contains about 30% propadiene. Detonation may occur at 95° C [MCA Case History No. 632]. Reacts exothermically with many oxidizing agents and with some reducing agents as well. May react with silver, copper, and mercury salts in aqueous solution to give explosive acetylides. Incompatible with brass that contains more than 65% copper, with other copper-containing alloys, with Monel metal, with neoprene, polyethylene, and, to a lesser extent, with Teflon. May enflame in air in the presence of Co, Hg, Hg salts, K, Ag, Ag salts, RbH, CsH, halogens, HNO3, NaH. Can decompose explosively when compressed to 4.5 to 5.6 atmospheres. Moderate explosion hazard when exposed to heat or flame or by spontaneous chemical reaction. Has been known to decompose explosively at high pressures and moderate temperatures in the absence of air.

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

Can react vigorously with oxidizing materials.

10.6 Hazardous decomposition products

When heated to decomposition it emits acrid smoke and irritating fumes.

SECTION 11: Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

The substance is irritating to the respiratory tract. Rapid evaporation of the liquid may cause frostbite. Exposure could cause lowering of consciousness.

STOT-repeated exposure

no data available

Aspiration hazard

On loss of containment this substance can cause suffocation by lowering the oxygen content of the air in confined areas.

SECTION 12: Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

A Rhodococcus species isolated from soil was able to use 1-propyne(1).

12.3 Bioaccumulative potential

An estimated BCF of 3 was calculated in fish for 1-propyne(SRC), using a log Kow of 0.94(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low.

12.4 Mobility in soil

The Koc of 1-propyne is estimated as 77(SRC), using a log Kow of 0.94(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that 1-propyne is expected to have high mobility in soil.

12.5 Other adverse effects

no data available

SECTION 13: Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

SECTION 14: Transport information

14.1 UN Number

ADR/RID: UN1206 (For reference only, please check.) IMDG: UN1206 (For reference only, please check.) IATA: UN1206 (For reference only, please check.)

14.2 UN Proper Shipping Name

ADR/RID: HEPTANES (For reference only, please check.) IMDG: HEPTANES (For reference only, please check.) IATA: HEPTANES (For reference only, please check.)

14.3 Transport hazard class(es)

ADR/RID: 3 (For reference only, please check.) IMDG: 3 (For reference only, please check.) IATA: 3 (For reference only, please check.)

14.4 Packing group, if applicable

ADR/RID: II (For reference only, please check.) IMDG: II (For reference only, please check.) IATA: II (For reference only, please check.)

14.5 Environmental hazards

ADR/RID: No IMDG: No IATA: No

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to IMO instruments

no data available

SECTION 15: Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
Propyne Propyne 74-99-7 200-828-4
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Not Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Not Listed.
Korea Existing Chemicals List (KECL) Listed.

SECTION 16: Other information

Information on revision

Creation Date July 15, 2019
Revision Date July 15, 2019

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Other Information

High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.Check oxygen content before entering area.After use for welding, turn valve off; regularly check tubing, etc., and test for leaks with soap and water.The measures mentioned in section PREVENTION are applicable to production, filling of cylinders, and storage of the gas.

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.

Propyne is included in Industrial Gases category.

Related Products

Industry News

More Safety Data Sheets

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.