Cyclohexene Safety Data Sheets
SAFETY DATA SHEETS
According to the UN GHS revision 8
SECTION 1: Identification
1.1 GHS Product identifier
| Product name | Cyclohexene |
|---|
1.2 Other means of identification
| Product number | - |
|---|---|
| Other names | Cykloheksen; TETRAHYDROBENZENE; 1,2,3,4-Tetrahydrobenzene |
1.3 Recommended use of the chemical and restrictions on use
| Identified uses | Industrial and scientific research uses. |
|---|---|
| Uses advised against | no data available |
1.4 Supplier's details
| Company | Echemi.com |
|---|---|
| Address | Echemi.com |
| Telephone | Echemi.com |
1.5 Emergency phone number
| Emergency phone number | Echemi.com |
|---|---|
| Service hours | Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours). |
SECTION 2: Hazard identification
2.1 Classification of the substance or mixture
Flammable liquids, Category 2
Acute toxicity - Category 4, Oral
Aspiration hazard, Category 1
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 2
2.2 GHS label elements, including precautionary statements
| Pictogram(s) | |
|---|---|
| Signal word | Danger |
| Hazard statement(s) | H225 Highly flammable liquid and vapour H302 Harmful if swallowed H304 May be fatal if swallowed and enters airways H411 Toxic to aquatic life with long lasting effects |
| Precautionary statement(s) | |
| Prevention | P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment. P242 Use non-sparking tools. P243 Take action to prevent static discharges. P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/... P264 Wash ... thoroughly after handling. P270 Do not eat, drink or smoke when using this product. P273 Avoid release to the environment. |
| Response | P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower]. P370+P378 In case of fire: Use ... to extinguish. P301+P317 IF SWALLOWED: Get medical help. P330 Rinse mouth. P301+P316 IF SWALLOWED: Get emergency medical help immediately. P331 Do NOT induce vomiting. P391 Collect spillage. |
| Storage | P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up. |
| Disposal | P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal. |
2.3 Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
3.1 Substances
| Chemical name | Common names and synonyms | CAS number | EC number | Concentration |
|---|---|---|---|---|
| Cyclohexene | Cyclohexene | 110-83-8 | 203-807-8 | 100% |
SECTION 4: First-aid measures
4.1 Description of necessary first-aid measures
If inhaled
Fresh air, rest.
Following skin contact
Remove contaminated clothes. Rinse and then wash skin with water and soap.
Following eye contact
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Following ingestion
Rinse mouth. Do NOT induce vomiting. Refer for medical attention .
4.2 Most important symptoms/effects, acute and delayed
Excerpt from ERG Guide 130 [Flammable Liquids (Water-Immiscible / Noxious)]: May cause toxic effects if inhaled or absorbed through skin. Inhalation or contact with material may irritate or burn skin and eyes. Fire will produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or suffocation. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)
4.3 Indication of immediate medical attention and special treatment needed, if necessary
Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary . Anticipate seizures and treat if necessary . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. Administer activated charcoal . Treat frostbite with rapid rewarming techniques ./Aliphatic hydrocarbons and related compounds/
SECTION 5: Fire-fighting measures
5.1 Suitable extinguishing media
If material on fire or involved in fire: Do not extinguish fire unless flow can be stopped or safely confined. Use water in flooding quantities as fog. Solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water. Use foam, dry chemical, or carbon dioxide. Keep run-off water out of sewers and water sources.
5.2 Specific hazards arising from the chemical
Excerpt from ERG Guide 130 [Flammable Liquids (Water-Immiscible / Noxious)]: HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. (ERG, 2016)
5.3 Special protective actions for fire-fighters
Use water spray, powder, foam, carbon dioxide. In case of fire: keep drums, etc., cool by spraying with water.
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Remove all ignition sources. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Do NOT wash away into sewer.
6.2 Environmental precautions
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Remove all ignition sources. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Do NOT wash away into sewer.
6.3 Methods and materials for containment and cleaning up
Remove all ignition sources. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent and remove to safe place. Do NOT wash away into sewer. Filter respirator for organic gases and vapours.
SECTION 7: Handling and storage
7.1 Precautions for safe handling
NO open flames, NO sparks and NO smoking. Closed system, ventilation, explosion-proof electrical equipment and lighting. Prevent build-up of electrostatic charges (e.g., by grounding). Do NOT use compressed air for filling, discharging, or handling. Use non-sparking handtools. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
7.2 Conditions for safe storage, including any incompatibilities
Fireproof. Separated from strong oxidants. Cool. Well closed. Store only if stabilized.Fireproof. Separated from strong oxidants. Cool. Well closed. Store only if stabilized.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Occupational Exposure limit values
TLV: 300 ppm as TWA
Biological limit values
no data available
8.2 Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
8.3 Individual protection measures, such as personal protective equipment (PPE)
Eye/face protection
Wear safety spectacles.
Skin protection
Protective gloves.
Respiratory protection
Use ventilation, local exhaust or breathing protection.
Thermal hazards
no data available
SECTION 9: Physical and chemical properties and safety characteristics
| Physical state | Cyclohexene is a colorless liquid. Insoluble in water and less dense than water. Flash point 20°F. Vapors heavier than air. Inhalation of high concentrations may have a narcotic effect. Used to make other chemicals. |
|---|---|
| Colour | Colorless liquid |
| Odour | Sweet odor |
| Melting point/freezing point | -104ºC |
| Boiling point or initial boiling point and boiling range | 83ºC |
| Flammability | Class IB Flammable Liquid: Fl.P. below 73°F and BP at or above 100°F. |
| Lower and upper explosion limit/flammability limit | Lower flammable limit: 0.8% by volume; Upper flammable limit: 2.8% by volume |
| Flash point | -20ºC |
| Auto-ignition temperature | 471 deg F (244 deg C) |
| Decomposition temperature | no data available |
| pH | no data available |
| Kinematic viscosity | 0.625 mPa.s at 25 deg C |
| Solubility | Insoluble (NIOSH, 2016) |
| Partition coefficient n-octanol/water | log Kow = 2.86 |
| Vapour pressure | 160 mm Hg ( 20 °C) |
| Density and/or relative density | 0.81 |
| Relative vapour density | 2.8 (vs air) |
| Particle characteristics | no data available |
SECTION 10: Stability and reactivity
10.1 Reactivity
The substance can form explosive peroxides. The substance may polymerize under certain conditions.
10.2 Chemical stability
no data available
10.3 Possibility of hazardous reactions
Highly flammable.The vapour is heavier than air and may travel along the ground; distant ignition possible. As a result of flow, agitation, etc., electrostatic charges can be generated.CYCLOHEXENE may react vigorously with strong oxidizing agents. May react exothermically with reducing agents to release hydrogen gas. In the presence of various catalysts (such as acids) or initiators, may undergo exothermic addition polymerization reactions. Oxidizes readily in air to form unstable peroxides that may explode spontaneously [Bretherick, 1979 p.151-154].
10.4 Conditions to avoid
no data available
10.5 Incompatible materials
Strong oxidizers [Note: Forms explosive peroxides with oxygen upon storage.]
10.6 Hazardous decomposition products
no data available
SECTION 11: Toxicological information
Acute toxicity
- Oral: LD50 Rat oral 2.4 mL (1946 mg)/kg
- Inhalation: no data available
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
The substance is irritating to the eyes, skin and respiratory tract. If this liquid is swallowed, aspiration into the lungs may result in chemical pneumonitis. The substance may cause effects on the central nervous system.
STOT-repeated exposure
The substance defats the skin, which may cause dryness or cracking.
Aspiration hazard
A harmful contamination of the air will be reached rather slowly on evaporation of this substance at 20°C.
SECTION 12: Ecological information
12.1 Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: EC50; Species: Daphnia magna (Water flea); Conditions: freshwater; /conditions of bioassay not specified/; Concentration: = 720 mg/L for 24 hr; Effect: behavior, equilibrium /formulated product
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
12.2 Persistence and degradability
AEROBIC: Cyclohexene, present at 100 mg/L, reached 0% of its theoretical BOD in 4 weeks using an activated sludge inoculum at 30 mg/L and the Japanese MITI test(1). Approximately 20% of THOD was observed when cyclohexene was incubated with activated sewage sludge acclimated to benzene(2). Cyclohexene did not support growth of two strains of Cladosporium resinae isolated from aircraft jet fuels systems when used as the sole carbon source(3,4). 2- and 3-cyclohexene-1-ol were produced in the oxidation of cyclohexene by Pseudomonas oleovorans(5).
12.3 Bioaccumulative potential
BCF values ranging from 23-45 and 12-38 were measured for carp exposed to 10 and 100 ug/L, respectively of cyclohexene during a 28 day incubation period(1). According to a classification scheme(2), this BCF range suggests bioconcentration in aquatic organisms is low to moderate(SRC).
12.4 Mobility in soil
The Koc of cyclohexene is estimated as 850 (SRC), using a log Kow of 2.86(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that cyclohexene is expected to have low mobility in soil(SRC).
12.5 Other adverse effects
no data available
SECTION 13: Disposal considerations
13.1 Disposal methods
Product
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Contaminated packaging
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
14.1 UN Number
| ADR/RID: UN2256 (For reference only, please check.) | IMDG: UN2256 (For reference only, please check.) | IATA: UN2256 (For reference only, please check.) |
14.2 UN Proper Shipping Name
| ADR/RID: CYCLOHEXENE (For reference only, please check.) | IMDG: CYCLOHEXENE (For reference only, please check.) | IATA: CYCLOHEXENE (For reference only, please check.) |
14.3 Transport hazard class(es)
| ADR/RID: 3 (For reference only, please check.) | IMDG: 3 (For reference only, please check.) | IATA: 3 (For reference only, please check.) |
14.4 Packing group, if applicable
| ADR/RID: II (For reference only, please check.) | IMDG: II (For reference only, please check.) | IATA: II (For reference only, please check.) |
14.5 Environmental hazards
| ADR/RID: Yes | IMDG: Yes | IATA: Yes |
14.6 Special precautions for user
no data available
14.7 Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
15.1 Safety, health and environmental regulations specific for the product in question
| Chemical name | Common names and synonyms | CAS number | EC number |
|---|---|---|---|
| Cyclohexene | Cyclohexene | 110-83-8 | 203-807-8 |
| European Inventory of Existing Commercial Chemical Substances (EINECS) | Listed. | ||
| EC Inventory | Listed. | ||
| United States Toxic Substances Control Act (TSCA) Inventory | Listed. | ||
| China Catalog of Hazardous chemicals 2015 | Listed. | ||
| New Zealand Inventory of Chemicals (NZIoC) | Listed. | ||
| Philippines Inventory of Chemicals and Chemical Substances (PICCS) | Listed. | ||
| Vietnam National Chemical Inventory | Listed. | ||
| Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) | Listed. | ||
| Korea Existing Chemicals List (KECL) | Listed. | ||
SECTION 16: Other information
Information on revision
| Creation Date | July 15, 2019 |
|---|---|
| Revision Date | July 15, 2019 |
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Other Information
An added stabilizer or inhibitor can influence the toxicological properties of this substance, consult an expert.Check for peroxides prior to distillation; render harmless if positive.
Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.
Cyclohexene is included in Other Chemical Drugs category.
Related Products
Industry News
More Safety Data Sheets