Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > Arsenic acid (H3AsO4), iron(2+) salt (2:3)

Arsenic acid (H3AsO4), iron(2+) salt (2:3)

Arsenic acid (H3AsO4), iron(2+) salt (2:3) structure

Arsenic acid (H3AsO4), iron(2+) salt (2:3) 

structure
  • CAS No:

    10102-50-8

  • Formula:

    AsH3O4.3/2Fe

  • Chemical Name:

    Arsenic acid (H3AsO4), iron(2+) salt (2:3)

  • Synonyms:

    Arsenic acid (H3AsO4),iron(2+) salt (2:3);Iron arsenate (Fe3(AsO4)2);Ferrous arsenate

Description

Ferrous arsenate is a green powder. It is insoluble in water. It is toxic by ingestion. It is used in insecticides.


Ferrous arsenate is a green powder. It is insoluble in water. It is toxic by ingestion. It is used in insecticides.

Arsenic acid (H3AsO4), iron(2+) salt (2:3) Basic Attributes

445.37 g/mol

445.60731 g/mol

233-275-2

129CO35H12

1608

A green powder

Characteristics

173 Ų

Green amorphous powder; insol in water; sol in acids /Hexahydrate/|Ferrous arsenate is insoluble in water.

Protect container against physical damage. Store in well ventilated area away from food or food products and combustible materials. /Inorganic arsenic compounds/

Soluble in dilute hydrochloric acid; slightly soluble in NH4OH /hexahydrate/|Sugar, glycerin, & many organic hydroxy acids hinder precipitation. In neutral solution, soluble carbonates, phosphates, & oxalates produce precipitation. /Ferrous salts/

Insoluble in water.

Non-Redox-Active Inorganic Compounds

FERROUS ARSENATE has weak oxidizing or reducing powers. Redox reactions can however still occur. The majority of compounds in this class are slightly soluble or insoluble in water. If soluble in water, then the solutions are usually neither strongly acidic nor strongly basic. These compounds are not water-reactive.

Safety Information

[40 CFR 240-280, 300-306, 702-799 (7/1/2004)] Generators of waste (equal to or greater than 100 kg/mo) containing this contaminant, EPA hazardous waste number D004, must conform with USEPA regulations in storage, transportation, treatment and disposal of waste.|Chemical Treatability of Arsenic; Concentration Process: Chemical Precipitation; Chemical Classification: Metal; Scale of Study: Pilot Scale; Type of Wastewater Used: Domestic Wastewater + Pure Compound; Results of Study: 5ppm @ 4gpm @ pH= 7.0. Iron system-90% reduction; low lime system-80% reduction; high lime system-76% reduction; (3 coagulant systems were used; Iron system used 45 ppm as Fe of Fe2(SO4)3 @ pH= 6.0. Low lime system used 20 ppm Fe of Fe2(SO4)3 and 260 ppm of CaO @ pH= 10.0. High lime system used 600 ppm of CaO @ pH= 11.5. Chemical coagulation was followed by multimedia filtration). /Arsenic cmpd/|Chemical Treatability of Arsenic; Concentration Process: Chemical Precipitation; Chemical Classification: Metal; Scale of Study: Full Scale Continuous Flow; Type of Wastewater Used: Domestic Wastewater; Results of Study: Effluent character (ppb): 2.5, 56% reduction with lime; 3.3, 24% reduction with lime; (lime dose of 350-400 ppm as calcium oxide @ pH= 11.3). /Arsenic cmpd/

... When water solutions of arsenicals are in contact with active metals such as arsenic, iron, aluminum, zinc, ... highly toxic fumes of arsenic /including arsine are released/. /Arsenic compounds/|Strong oxidizers, bromide azide [Note: Hydrogen gas can react with inorganic arsenic to form the highly toxic gas arsine.] /Arsenic (inorganic compounds, as As)/

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Containers may explode when heated. Runoff may pollute waterways. (ERG, 2016)|Carcinogens, Reactive - 1st degree

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Cover with plastic sheet to prevent spreading. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2016)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)|Personnel protection: ... Wear appropriate chemical protective gloves, boots and goggles.|Workers should be supplied with suitable protective clothing, protective boots and when there is a risk that the exposure limit for airborne arsenic will be exceeded, respiratory protective equipment. /Arsenic cmpd/|Where there is occupational exposure to inorganic arsenic compounds, protective clothing shall be provided by the employers. This may include underwear, gloves, coveralls, and a hood over the head and neck. /Inorganic arsenic/|Wear appropriate personal protective clothing to prevent skin contact. /Arsenic (inorganic cmpd, as As)/|For more Personal Protective Equipment (PPE) (Complete) data for FERROUS ARSENATE (7 total), please visit the HSDB record page.

If material is involved in fire: Extinguish fire using agent suitable for type of surrounding fire. (Material itself does not burn or burns with difficulty.) Use water in flooding quantities as fog. Use foam, dry chemical, or carbon dioxide.

Both arsenate and arsenite can be removed from the water column by co-precipitation or adsorption onto iron oxides. Arsenate species can also be removed by adsorption onto aluminum hydroxide and clays, while arsenite is readily adsorbed onto metal sulfides. /Arsenate and arsenite/|Floors and other accessible surfaces contaminated with inorganic arsenic may not be cleaned by the use of compressed air, and shoveling and brushing may be used only where vacuuming or other relevant methods have been tried and found not to be effective. /Inorganic arsenic compounds/

SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants.|SRP: Contaminated protective clothing should be segregated in such a manner so that there is no direct personal contact by personnel who handle, dispose, or clean the clothing. Quality assurance to ascertain the completeness of the cleaning procedures should be implemented before the decontaminated protective clothing is returned for reuse by the workers. All contaminated clothing should not be taken home at end of shift, but should remain at employee's place of work for cleaning.|SRP: The scientific literature for the use of contact lenses in industry is conflicting. The benefit or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.|If material not involved in fire: Keep material out of water sources and sewers.|For more Preventive Measures (Complete) data for FERROUS ARSENATE (18 total), please visit the HSDB record page.

/GUIDE 151: SUBSTANCES - TOXIC (Non-combustible)/ Fire or Explosion: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Containers may explode when heated. Runoff may pollute waterways.|/GUIDE 151: SUBSTANCES - TOXIC (Non-combustible)/ Health: Highly toxic, may be fatal if inhaled, swallowed or absorbed through skin. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution.|/GUIDE 151: SUBSTANCES - TOXIC (Non-combustible)/ Public Safety: CALL Emergency Response Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover. As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind. Keep out of low areas.|/GUIDE 151: SUBSTANCES - TOXIC (Non-combustible)/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible.|For more DOT Emergency Guidelines (Complete) data for FERROUS ARSENATE (8 total), please visit the HSDB record page.

No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./|The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials.|The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article.

... Strong irritant. /dihydrate/|Arsenical dusts ... are irritating to upper respiratory tract & eyes. Conjunctivitis produced by ... these substances are characterized by itching, burning, and watering of eyes. /Inorganic arsenic dusts/|If inhaled, iron is a local irritant to the lung and gastrointestinal tract. /Iron compounds/

Permissable Exposure Limit: 8 hr Time-Weighted avg: 10 ug/cu m./Arsenic, inorganic cmpd (as As)/

NIOSH considers arsenic (inorganic cmpd, as As) to be a potential occupational carcinogen. /Arsenic (inorganic cmpd, as As)/|Recommended Exposure Limit: 15 minute Ceiling Limit: (0.002 mg/cu m). /Arsenic (inorganic cmpd, as As)/

Listed as a hazardous air pollutant (HAP) generally known or suspected to cause serious health problems. The Clean Air Act, as amended in 1990, directs EPA to set standards requiring major sources to sharply reduce routine emissions of toxic pollutants. EPA is required to establish and phase in specific performance based standards for all air emission sources that emit one or more of the listed pollutants. Ferrous arsenate is included on this list.|(a) The owner or operator of an existing glass melting furnace subject to the provisions of this subpart shall comply with either paragraph (a)(1) or (a)(2) of this section ... (1) Uncontrolled total arsenic emissions from the glass melting furnace shall be less than 2.5 Mg (2.7 ton) per year, or ... (2) Total arsenic emissions from glass melting furnace shall be conveyed to a control device and reduced by at least 85%. /Total arsenic/|(b) The owner or operator of a new or modified glass melting furnace subject to the provisions of this subpart shall comply with either paragraph (b)(1) or (b)(2) of this section ... (1) Uncontrolled total arsenic emissions from the glass melting furnace shall be less than 0.4 Mg (0.44 ton) per year, or ... (2) Total arsenic emissions from glass melting furnace shall be conveyed to a control device and reduced by at least 85%. /Total arsenic/|The owner or operator of each copper converter subject to the provisions of this subpart shall reduce inorganic arsenic emissions to the atmosphere by meeting the following design, equipment, work practice, and operational requirements: (1) Install, operate, and maintain a secondary hood system on each copper converter. Each secondary hood system shall consist of a hood enclosure, air curtain fan(s), exhaust system fan(s), and ductwork that conveys the captured emission to a control device ... (2) Optimize the capture of secondary inorganic arsenic emission by operating the copper converter and secondary hood systems at all times ... . /Inorganic arsenic/|For more Atmospheric Standards (Complete) data for FERROUS ARSENATE (6 total), please visit the HSDB record page.

D004; A waste containing arsenic may or may not be characterized as a hazardous waste following testing by the Toxicity Characteristic Leaching Procedure as prescribed by the Resource Conservation and Recovery Act (RCRA) regulations. /Arsenic/

D004; A solid waste containing arsenic may or may not become characterized as a hazardous waste when subjected to the Toxicity Characteristic Leaching Procedure listed in 40 CFR 261.24, and if so characterized, must be managed as a hazardous waste.

Drug Information

VET: /Formerly/ as a hematinic tonic for cats & dogs in convalescence from surgery or chronic debilitating diseases. ... Formerly used as anthelmintic for lambs.

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Highly toxic, may be fatal if inhaled, swallowed or absorbed through skin. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. /Iron and related compounds/|Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious. Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start an IV with lactated Ringer's /SRP: "To keep open", minimal flow rate/. Watch for signs of fluid overload. For hypotension with signs of hypovolemia, administer fluid cautiously. Watch for signs of fluid overload ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Iron and related compounds/|Maintain an open airway and assist ventilation if necessary. Treat shock caused by hemorrhagic gastrointestinitis aggressively with intravenous crystalloid fluids, and replace blood if needed. Patients are often markedly hypovolemic owing to gastrointestinal losses and third spacing of fluids into the intestinal wall and interstitial space. Treat coma, seizures, and metabolic acidosis if they occur. For seriously intoxicated victims (eg, shock, severe acidosis, and/or serum iron > 500-600 mcg/dL) administer deferoxamine. Monitor the urine for the urine for the characteristic orange or pink deferoxamine-iron complex. Therapy may be stopped when the urine returns to normal or when the serum iron level decreases to the normal range. Prolonged deferoxamine has been associated with adult respiratory distress syndrome and Yersinia sepsis.|Activated charcoal is not effective. Ipecac is not recommended, because it can aggravate iron-induced gastrointestinal irritation and interfere with whole bowel irrigation. Consider gastric lavage if product was a liquid formulation or tablets were chewed. Do-not use phosphate-containing solutions for lavage; these may result in life-threatening hypernatremia, hyperphosphatemia, and hypocalcemia. Bicarbonate and deferoxamine lavage are of doubtful efficacy. Deferoxamine lavage is not effective and may enhance iron absorption. Whole-bowel irrigation is very effective for ingested tablets and may be considered first-line treatment, especially if large numbers of tablets are visible on plain abdominal x-ray. Massive ingestions may lead to concretions or bezoars. Repeated or prolonged whole-bowel irrigation may remove tablets. Endoscopy or surgical gastrotomy is rarely required.|Hemodialysis and hemoperfusion are not effective for removing iron but may be necessary to remove iron-deferoxamine complex in patients with renal failure. Exchange transfusion is occasionally used for massive pediatric ingestions but is of questionable efficacy.

/SIGNS AND SYMPTOMS/ Symptoms of conjunctivitis, bronchitis and dyspnea, followed by gastrointestinal discomfort with vomiting, and subsequent cardiac involvement with irreversible shock, may occur in a time course of hours. /Arsenic and arsenic compounds/|/SIGNS AND SYMPTOMS/ With exposure to sub-lethal doses of irritant arsenic compounds in air, there may be symptoms related to acute damage to the the mucous membranes of the respiratory system and acute symptoms from exposed skin. Severe irritation of the nasal mucosa, larynx and bronchi, as well as conjunctivitis and dermatitis occur in such cases. Perforation of the nasal septum can be observed in some individuals only after a few weeks following exposure. /Arsenic and arsenic compounds/

Arsenic acid (H3AsO4), iron(2+) salt (2:3) Use and Manufacturing

Methods of Manufacturing

Interaction of soln of sodium arsenate and ferrous sulfate. /Hexahydrate/

Fire Hazards -> Carcinogens, Reactive - 1st degree

Computed Properties

Molecular Weight:445.37
Hydrogen Bond Acceptor Count:8
Exact Mass:445.60731
Monoisotopic Mass:445.60731
Topological Polar Surface Area:173
Heavy Atom Count:13
Complexity:36.8
Covalently-Bonded Unit Count:5
Compound Is Canonicalized:Yes

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.