Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > (24R)-3β-(Trimethylsiloxy)ergosta-5-ene

(24R)-3β-(Trimethylsiloxy)ergosta-5-ene

(24R)-3β-(Trimethylsiloxy)ergosta-5-ene structure

(24R)-3β-(Trimethylsiloxy)ergosta-5-ene 

structure
  • CAS No:

    55429-62-4

  • Formula:

    C31H56OSi

  • Chemical Name:

    (24R)-3β-(Trimethylsiloxy)ergosta-5-ene

  • Synonyms:

    (24R)-3β-(Trimethylsiloxy)ergosta-5-ene;[(24R)-24-Methylcholest-5-en-3β-yl] (trimethylsilyl) ether;[[(24R)-Ergost-5-en-3β-yl]oxy]trimethylsilane;Campesteryl trimethylsilyl ether;Ergost-5-ene, 3-[(trimethylsilyl)oxy]-, (3β,24R)-

(24R)-3β-(Trimethylsiloxy)ergosta-5-ene Basic Attributes

472.86

472.41

Characteristics

9.23

9.4939

0.94±0.1 g/cm3(Predicted)

498.6±24.0 °C(Predicted)

Analysis Methods

Name Column Shape Active Phase(℃) Retention index Temperature Control Method Comments Reference
Van Den Dool and Kratz RI, non-polar column, temperature ramp Capillary DB-5MS 3249.5 temperature ramp 10. m/0.18 mm/0.18 μm, 70. C @ 2. min, 40. K/min, 320. C @ 2. min Jonsson, P.Johansson, A.I.Gullberg, J.Trygg, J.Jiye, A.Grung, B.Marklund, S.Sjöström, M.Antti, H.Moritz, T.High-throughput data analysis for detecting and identifying differences between samples in GC/MS-based metabolomic analysesAnal. Chem.2005, 77, 17, 5635-5642.
Van Den Dool and Kratz RI, non-polar column, temperature ramp Capillary RTX-5 Sil MS 3263. temperature ramp 30. m/0.25 mm/0.25 μm, Helium, 70. C @ 5. min, 5. K/min, 310. C @ 1. min Lytovchenko, A.Beleggia, R.Schauer, N.Isaacson, T.Leuendorf, J.E.Hellmann, H.Rose, J.K.C.Fernie, A.R.Application of GC-MS fpr the detection of lipophilic compounds in diverse plant tissuesPlant Methods2009, 5, 4, 1-11.
Van Den Dool and Kratz RI, non-polar column, temperature ramp Capillary HP-5 3253. temperature ramp 30. m/0.25 mm/0.25 μm, Helium, 3. K/min, 300. C @ 30. min; Tstart: 50. C Isidorov, V.A.Lech, P.Zolciak, A.Rusak, N.Szczepaniak, L.Gas Chromatographic - nass spectrometric investigation of metabolites from the needles and roots of pine seedlings at early stages of pathogenic fungi Armillaria ostoyae attackTrees2008, 22, 4, 531-542.
Van Den Dool and Kratz RI, non-polar column, temperature ramp Capillary DB-5MS 3204. temperature ramp 30. m/0.25 mm/0.25 μm, He, 60. C @ 2. min, 6. K/min, 300. C @ 15. min Rogge, W.F.Medeiros, P.M.Simoneit, B.R.T.Organic marker compounds for surface soil and fugitive dust from open lot dairies and cattle feedlotsAtmos. Environ.2006, 40, 1, 27-49.
Guide of (24R)-3β-(Trimethylsiloxy)ergosta-5-ene

Request for Quotation

Share

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.