Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > Mercurate(2-), tetrakis(cyano-κC)-, potassium (1:2)

Mercurate(2-), tetrakis(cyano-κC)-, potassium (1:2)

Mercurate(2-), tetrakis(cyano-κC)-, potassium (1:2) structure

Mercurate(2-), tetrakis(cyano-κC)-, potassium (1:2) 

structure
  • CAS No:

    591-89-9

  • Formula:

    C4HgN4.2K

  • Chemical Name:

    Mercurate(2-), tetrakis(cyano-κC)-, potassium (1:2)

  • Synonyms:

    Mercurate(2-),tetrakis(cyano-κC)-,potassium (1:2);Mercurate(2-),tetracyano-,dipotassium;Mercurate(2-),tetrakis(cyano-C)-,dipotassium,(T-4)-;Potassium tetracyanomercurate(II);Potassium cyanomercurate(II);Mercurate(2-),tetrakis(cyano-κC)-,dipotassium,(T-4)-;Mercuric potassium cyanide;Potassium tetracyanomercurate (K2Hg(CN)4);Dipotassium tetracyanomercurate(2-);Dipotassium tetracyanomercurate;Mercury potassium cyanide (HgK2(CN)4);1276031-29-8

  • Categories:

    Inorganic Chemistry  >  Inorganic Salts

Description

Colorless crystals. Soluble in water and alcohol.


Mercuric potassium cyanide appears as a colorless crystalline solid. Denser than water. Toxic by inhalation and ingestion. Produces toxic oxides of nitrogen during combustion.


Mercuric potassium cyanide appears as a colorless crystalline solid. Denser than water. Toxic by inhalation and ingestion. Produces toxic oxides of nitrogen during combustion.

Mercurate(2-), tetrakis(cyano-κC)-, potassium (1:2) Basic Attributes

382.86

383.91000

209-735-3

AZ01173G23

1626

Colorless or white crystals

Characteristics

95.16000

0.06462

Mercuric potassium cyanide appears as a colorless crystalline solid. Denser than water. Toxic by inhalation and ingestion. Produces toxic oxides of nitrogen during combustion.

soluble H2O [MER06]

Non-combustible; in case of water, moisture and acid decomposition of toxic hydrogen hydride gas

Soluble in water. Rapidly decomposes in presence of acids with generation of hydrogen cyanide, a flammable poison gas.

Cyanides, Inorganic

MERCURIC POTASSIUM CYANIDE is rapidly decomposed by acids to evolve hydrogen cyanide, a flammable poisonous gas. May tend to explosive instability. Incompatible with strong oxidizing agents. Fusion with metal chlorates, perchlorates, nitrates or nitrites can cause violent explosions [Bretherick 1979. p. 101]. Contact with ammonia may be explosive.

Safety Information

I

6.1(a)

1626

Treasury is ventilated, low temperature and dry; stored and transported separately from chlorate and sodium nitrite (potassium)

Explosive when mixed with chlorate, sodium nitrite (potassium)

Generators of waste (equal to or greater than 100 kg/mo) containing this contaminant, EPA hazardous waste number D009, must conform with USEPA regulations in storage, transportation, treatment and disposal of waste.|Generators of waste (equal to or greater than 100 kg/mo) containing this contaminant, EPA hazardous waste number D003, P030, must conform with USEPA regulations in storage, transportation, treatment and disposal of waste.

May explode on contact with ammonia.|Contact may be explosive, possibly owing to rapid oxidation of ammonia by alkaline 'ferricyanide'.

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. For UN1796, UN1826, UN2031 at high concentrations and for UN2032, these may act as oxidizers, also consult ERG Guide 140. Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.). Substance may react with water (some violently), releasing corrosive and/or toxic gases and runoff. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water. (ERG, 2016)

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. DO NOT GET WATER INSIDE CONTAINERS. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas. SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2016)

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)

MODERATE, BY CHEM REACTION WITH HEAT, MOISTURE, ACID; EMIT HYDROCYANIC ACID. /CYANIDES/

If mercuric potassium cyanide involved in fire: Extinguish fire using agent suitable for type of surrounding fire. (Material itself does not burn or burns with difficulty.) Use "alcohol" foam, dry chemical or carbon dioxide. Do not use water on material itself. If large quantities of combustibles are involved, use water in flooding quantities as spray and fog. Use water spray to knock-down vapors.

Mercury spills should be cleaned up immediately by use of a special vacuum cleaner. Then the area should be washed with a dilute calcium sulfide solution. Small quantities of mercury can be picked up by mixing with copper metal granules. ... /Mercury/|Mercury removal from waste water can be accomplished by these processes: BMS process; Chlorine is added to the waste water, oxidizing any mercury present to the ionic state. The BMS adsorbent (an activated carbon concentrate of sulfur cmpd on its surface) is used to collect ionic mercury. The spent adsorbent is then distilled to recover the mercury, leaving a carbon residue for reuse or disposal. TMR IMAC Process; Waste water is fed into a reactor, whereby a slight excess of chlorine is maintained, oxidizing any mercury present to ionic mercury. The liquid is then passed through the TMR IMAC ion-exchange resin where mercury ions are adsorbed. The mercury is then stripped from the spent resin with hydrochloric acid solution. /Mercury cmpds/|SPILLED MERCURY CMPD OR SOLN CAN BE CLEANED UP BY ANY METHOD THAT DOES NOT CAUSE EXCESSIVE AIRBORNE CONTAMINATION OR SKIN CONTACT. /MERCURY COMPOUNDS/|1) Ventilate area of spill. 2) Collect spilled material for reclamation using commercially available mercury vapor depressants or specialized vacuum cleaners. /Inorganic mercury/

Personnel protection: Avoid breathing dusts. Keep upwind. ... Avoid bodily contact with the material. ... Do not handle broken packages unless wearing appropriate personal protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. If contact with the material anticipated, wear appropriate chemical protective clothing.|If material not involved in fire: Keep sparks, flames, and other sources of ignition away. Keep materail out of water sources and sewers. Do not use water on material itself.|Preventative measure: adequate ventilation; careful attention to good housekeeping, e.g., avoidance of spills, and prompt and proper cleaning if a spill occurs; all containers of mercury and its compounds should be kept tightly closed; should be washed on a regular basis with dilute calcium sulfide solution or other suitable reactant; floors should be nonporous; all workers directly involved in the plant operation should shower thoroughly each day before leaving. /Mercury compounds/

/GUIDE 157: SUBSTANCES - TOXIC AND/OR CORROSIVE (NON-COMBUSTIBLE/WATER -SENSITIVE)/ Health: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns, or death. Reaction with water or moist air will release toxic, corrosive or flammable gases. Reaction with water may generate much heat which will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution.|/GUIDE 157: SUBSTANCES - TOXIC AND/OR CORROSIVE (NON-COMBUSTIBLE/WATER -SENSITIVE)/ Fire or Explosion: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars etc.). Substance will react with water (some violently), releasing corrosive and/or toxic gases. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or contaminated with water.|/GUIDE 157: SUBSTANCES - TOXIC AND/OR CORROSIVE (NON-COMBUSTIBLE/WATER -SENSITIVE)/ Public Safety: CALL Emergency Response Telephone Number ... . As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate enclosed areas.|/GUIDE 157: SUBSTANCES - TOXIC AND/OR CORROSIVE (NON-COMBUSTIBLE/WATER -SENSITIVE)/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible.|For more DOT Emergency Guidelines (Complete) data for MERCURIC POTASSIUM CYANIDE (8 total), please visit the HSDB record page.

No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./|The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials.|The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article.

Permissible Exposure Limit: Table Z-1 8-hr Time-Weighted Avg: 5 mg/cu m. Skin Designation. /Cyanides, as CN/|Vacated 1989 OSHA PEL still enforced in some states: Hg vapor, TWA 0.05 mg/cu m, skin; Non-alkyl cmpds, Ceiling 0.1 mg/cu m, skin. /Mercury cmpd, as Hg, (except (organo) alkyls)/

Recommended Exposure Limit: 10 Hr Time-Weighted Avg: 0.05 mg/cu m, skin (Hg vapor). /Mercury [except (organo) alkyls] (as Hg)/|Recommended Exposure Limit: Ceiling Value: 0.1 mg/cu m, skin. /Mercury compounds [except (organo) alkyls] (as Hg)/

Listed as a hazardous air pollutant (HAP) generally known or suspected to cause serious health problems. The Clean Air Act, as amended in 1990, directs EPA to set standards requiring major sources to sharply reduce routine emissions of toxic pollutants. EPA is required to establish and phase in specific performance based standards for all air emission sources that emit one or more of the listed pollutants. Mercuric potassium cyanide is included on this list.

P030; An acute hazardous waste when a discarded commercial chemical product or manufacturing chemical intermediate or an off-specification commercial chemical product or a manufacturing chemical intermediate. /Cyanides (soluble salts), NOS/|D003; /SRP:/ A waste containing cyanide may (or may not) be characterized a hazardous waste following testing for the reactivity characteristics as prescribed by the Resource Conservation and Recovery Act (RCRA) regulations.|D009; Mercury. A waste containing mercury may or may not be characterized as a hazardous waste following testing by the Toxicity Characteristic Leaching Procedure as prescribed by the Resource Conservation and Recovery Act (RCRA) regulations. /Mercury/

P030; As stipulated in 40 CFR 261.33, when mercuric potassium cyanide, as a commercial chemical product or manufacturing chemical intermediate or an off-specification commercial chemical product or a manufacturing chemical intermediate, becomes a waste, it must be managed according to federal and/or state hazardous waste regulations. Also defined as a hazardous waste is any container or inner liner used to hold this waste or any residue, contaminated soil, water, or other debris resulting from the cleanup of a spill, into water or on dry land, of this waste. Generators of small quantities of this waste may qualify for partial exclusion from hazardous waste regulations (40 CFR 261.5(e)). /Cyanides (soluble salts), NOS/|/SRP:/ D003; A solid waste containing cyanide may become characterized as a hazardous waste when subjected to testing for reactivity as stipulated in 40 CFR 261.23, and if so characterized, must be managed as a hazardous waste.|D009; A solid waste containing mercury may or may not become characterized as a hazardous waste when subjected to the Toxicity Characteristic Leaching Procedure listed in 40 CFR 261.24, and if so characterized, must be managed as a hazardous waste. /Mercury/

Toxicity

most toxic

Drug Information

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death. Reaction with water or moist air may release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. In case of contact with Hydrofluoric acid (UN1790), flush with large amounts of water. For skin contact, if calcium gluconate gel is available, rinse 5 minutes, then apply gel. Otherwise, continue rinsing until medical treatment is available. For eyes, flush with water or a saline solution for 15 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

Basic Treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 l/min. Administer amyl nitrite ampules as per protocol and physician order ... . Monitor for shock and treat if necessary ... . Monitor for pulmonary edema and treat if ... . Anticipate seizures and treat if necessary ... . For eye contamination, Rush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . /Cyanide and related compounds/|Advanced Treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious or in respiratory arrest. Positive pressure ventilation techniques with a bag valve mask device may be beneficial. Start an IV with D5W /SRP: "To keep open", minimal flow rate/. Use lactated Ringer's if signs of hypovolemia are present. Watch for signs of fluid overload. Administer cyanide antidote kit as per protocol and physician order ... . Monitor and treat cardiac arrhythmias if necessary ... . Consider vasopressors to treat hypotension without signs of hypovolemia ... . Consider drug therapy for pulmonary edema ... . Treat seizures with diazepam (Valium) ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Cyanide and related compounds/|Basic Treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and neat if necessary ... . Monitor for shock and treat if necessary ... . Anticipate seizures and treat if necessary ... . For eye contamination, flush eyes immediately with available water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. Administer activated charcoal ... . /Mercury and related compounds/|Advanced Treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient with severe pulmonary edema or respiratory arrest. Positive pressure ventilation techniques with a bag valve mask device may be beneficial. Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start an IV with D5W Use lactated Ringer's if signs of hypovolemia are present. Watch for signs of fluid overload. Consider drug therapy for pulmonary edema ... . For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors if hypotensive with a normal fluid volume. Watch for signs of fluid overload ... . Treat seizures with diazepam (Valium) ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Mercury and related compounds/

Mercurate(2-), tetrakis(cyano-κC)-, potassium (1:2) Use and Manufacturing

Methods of Manufacturing

By mixing mercuric and potassium cyanides and crystallizing.

Uses

In manufacture of mirrors to prevent the silver coating from becoming yellow; as reagent in testing for free acids.

Computed Properties

Molecular Weight:382.86
Hydrogen Bond Acceptor Count:5
Exact Mass:383.910353
Monoisotopic Mass:383.910353
Topological Polar Surface Area:95.2
Heavy Atom Count:11
Complexity:236
Covalently-Bonded Unit Count:3
Compound Is Canonicalized:Yes

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.