tert-Butyl methacrylate
-
tert-Butyl methacrylate
structure -
-
CAS No:
585-07-9
-
Formula:
C8H14O2
-
Chemical Name:
tert-Butyl methacrylate
-
Synonyms:
2-Propenoic acid,2-methyl-,1,1-dimethylethyl ester;Methacrylic acid,tert-butyl ester;tert-Butyl methacrylate;1,1-Dimethylethyl methacrylate;tert-Butyl α-methacrylate;Acryester TB;tert-Butyl 2-methylpropenoate;NSC 20957;Light Ester TB;tert-Butyl alcohol methacrylate;tert-Butyl 2-methylacrylate;Acryester TBMA
- Categories:
-
CAS No:
Description
Colorless liquid
Tert-butyl methacrylate appears as a colorless liquid with an ester like odor. Less dense than water and insoluble in water.|Liquid
Tert-butyl methacrylate appears as a colorless liquid with an ester like odor. Less dense than water and insoluble in water.
tert-Butyl methacrylate Basic Attributes
142.2
142.20
209-548-7
F9029V5818
20957
1993
DTXSID3060405
29161400
Characteristics
26.3
2.5
Tert-butyl methacrylate appears as a colorless liquid with an ester like odor. Less dense than water and insoluble in water.
0.8746 g/cm3 @ Temp: 20 °C
-60°C
67 °C
81
n20/D 1.415(lit.)
0.01 M
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
Highly flammable. Insoluble in water.
Acrylates and Acrylic Acids
Highly Flammable
TERT-BUTYL METHACRYLATE is an acrylate ester. Esters react with acids to liberate heat along with alcohols and acids. Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products. Heat is also generated by the interaction of esters with caustic solutions. Flammable hydrogen is generated by mixing esters with alkali metals and hydrides.
Safety Information
1993
1
R10
16
OZ3675500
Xi
P210, P233, P240, P241, P242, P243, P280, P303+P361+P353, P370+P378, P403+P235, P501
H226
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. Substance may be transported hot. For hybrid vehicles, ERG Guide 147 (lithium ion batteries) or ERG Guide 138 (sodium batteries) should also be consulted. If molten aluminum is involved, refer to ERG Guide 169. (ERG, 2016)
|Warning|H226 (79.06%): Flammable liquid and vapor [Warning Flammable liquids]|P210, P233, P240, P241, P242, P243, P261, P264, P271, P280, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P312, P321, P332+P313, P337+P313, P362, P370+P378, P403+P233, P403+P235, P405, and P501|Aggregated GHS information provided by 262 companies from 10 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.|H226: Flammable liquid and vapor [Warning Flammable liquids]|P210, P233, P240, P241, P242, P243, P280, P303+P361+P353, P370+P378, P403+P235, and P501
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: CAUTION: All these products have a very low flash point: Use of water spray when fighting fire may be inefficient. CAUTION: For mixtures containing alcohol or polar solvent, alcohol-resistant foam may be more effective. SMALL FIRE: Dry chemical, CO2, water spray or regular foam. LARGE FIRE: Water spray, fog or regular foam. Do not use straight streams. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions. LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet). FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material. LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2016)
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing will only provide limited protection. (ERG, 2016)
Drug Information
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: Inhalation or contact with material may irritate or burn skin and eyes. Fire may produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or suffocation. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. Wash skin with soap and water. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. Keep victim calm and warm. (ERG, 2016)
tert-Butyl methacrylate Use and Manufacturing
Intermediates
Paint and coating manufacturing|2-Propenoic acid, 2-methyl-, 1,1-dimethylethyl ester: ACTIVE|PMN - indicates a commenced PMN (Pre-Manufacture Notices) substance.
Computed Properties
Molecular Weight:142.20
XLogP3:2.5
Hydrogen Bond Acceptor Count:2
Rotatable Bond Count:3
Exact Mass:142.099379685
Monoisotopic Mass:142.099379685
Topological Polar Surface Area:26.3
Heavy Atom Count:10
Complexity:151
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes
Recommended Suppliers of tert-Butyl methacrylate
-
CN
2 YRS
Business licensedTrader Supplier of HPMC,Lithium Carbonate,Cellulose Acetate Tow,EVA resin,Terpene Resin,PP fiber,White Oil,LABSA,Sunflower oil,Carbon Black,Potassium Sorbate,Xanthan Gum,Neodymium Oxide,Tungsten Powder,Amfonelic Acid,Titanium DioxideInquiryCAS No.: 585-07-9Grade: Industrial GradeContent: 99.9% -
CN
5 YRS
Business licensedTrader Supplier of Intermediates,Building blocks,API,Silicones,Peptides,Lab chemicals,Biochemicals,Pharmaceuticals,Screening Compounds,Food Additives -
CN
4 YRS
Business licensedTrader Supplier of Semaglutide,Tirzepatide,API,EnzymeInquiryCAS No.: 585-07-9Grade: Industrial GradeContent: 99.50% -
CN
4 YRS
Business licensed Certified factoryManufactory Supplier of Flavors & Fragrances,Catalyst & Auxiliary,Intermediates,Dyes & Pigments,Inorganic Chemistry,petro chemicals,Surfactant,Food Additives,Water Treatment Chemicals -
CN
2 YRS
Business licensedTrader Supplier of API,Antibiotics,Anti cancer categoryInquiryUnit Price: $1 /KG EXWCAS No.: 585-07-9Grade: pharmaceutical gradeContent: 99%
Learn More Other Chemicals
-
Defluoro Atorvastatin Acetonide tert-Butyl Ester
1105067-91-1
-
tert-butyl 4-[(3-iodophenyl)methyl]piperazine-1-carboxylate
850375-09-6
-
tert-butyl 1-methylsulfanylethylsulfanylformate
36852-51-4
-
tert-butyl 4-oxaspiro[2.5]octane-5-carboxylate Formula
73806-22-1
-
(3-BROMO-4,5-DIHYDRO-ISOXAZOL-5-YLMETHYL)-CARBAMIC ACID TERT-BUTYL ESTER Formula
109770-82-3
-
4-(6-Bromo-pyridin-2-yl)-3-methyl-piperazine-1-carboxylic acid tert-butyl ester Formula
1289388-57-3
-
2-[(5-Bromo-thiophene-2-sulfonylamino)-methyl]-pyrrolidine-1-carboxylic acid tert-butyl ester Structure
1261230-34-5
-
tert-butyl (2S)-2-[[2-[[(2S)-2-(methylamino)propanoyl]amino]-2-oxoethyl]carbamoyl]pyrrolidine-1-carboxylate Structure
103137-94-6
-
What is tert-butyl (2S)-2-amino-3-azidopropanoate
108283-47-2
-
What is tert-butyl tetradecanoate
32429-42-8