Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > Molybdenum pentachloride

Molybdenum pentachloride

Molybdenum pentachloride structure

Molybdenum pentachloride 

structure
  • CAS No:

    10241-05-1

  • Formula:

    Cl5Mo

  • Chemical Name:

    Molybdenum pentachloride

  • Synonyms:

    Molybdenum chloride (MoCl5);Molybdenum pentachloride;Pentachloromolybdenum;Molybdenum(V) chloride

  • Categories:

    Inorganic Chemistry  >  Inorganic Salts

Description

Molybdenum pentachloride is a green-black odorless solid. It is toxic by ingestion and an irritant to skin. It may react with water to produce corrosive hydrochloric acid and toxic fumes.


Molybdenum pentachloride is a green-black odorless solid. It is toxic by ingestion and an irritant to skin. It may react with water to produce corrosive hydrochloric acid and toxic fumes.


Molybdenum pentachloride is a green-black odorless solid. It is toxic by ingestion and an irritant to skin. It may react with water to produce corrosive hydrochloric acid and toxic fumes.|Molybdenum pentachloride is a molybdenum halide.

Molybdenum pentachloride Basic Attributes

273.2

272.75000

233-575-3

2508

DTXSID0065012

28273985

Characteristics

0

3.44750

White to gray powder

2.928 g/mL at 25 °C(lit.)

194 °C

352 °C

soluble in dry ether, dry alcohol, organic solvents and chlorinated solvents.

1.75 mm Hg ( 25 °C)

In case of H, the pore-forming agent is combustible; in case of cyanide, it emits toxic hydrogen cyanide gas; when heated, it decomposes toxic chloride and molybdenum-containing fumes

Molybdenum pentachloride may react with water to produce corrosive hydrochloric acid and toxic fumes.

Halogenating Agents

Water-Reactive

MOLYBDENUM PENTACHLORIDE is a corrosive, hygroscopic solid, on contact with water or steam it decomposes to form hydrochloric acid. When heated to decomposition it emits toxic fumes of molybdenum chlorides and metallic molybdenum [Lewis, 3rd ed., 1993, p. 892]. Explodes on contact with finely divided sodium [Berry D. H., Chem. Eng. News, 1989, 67(47), p. 2]. Reaction with finely divided sodium sulfide is violent, may lead to autoignition [Kaner, R. B., Nature, 1991, 349, p. 510].

Safety Information

III

8

UN 2508 8/PG 3

3

29-34-48/20/22-40

26-36/37/39-43-45

QA4690000

C

The warehouse is ventilated and dried at low temperature; stored separately from oxidants, cyanides, H pore-forming agents and alkalis.

Stable, but moisture and air-sensitive. Contact with water liberates toxic gas. Incompatible with water, strong oxidizing agents.

P280-P305 + P351 + P338-P310

H314-H351

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Combustible material: may burn but does not ignite readily. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapors may travel to source of ignition and flash back. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water. (ERG, 2016)|Corrosives, Reactive - 2nd degree

|Danger|H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation]|P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P405, and P501|Aggregated GHS information provided by 68 companies from 4 notifications to the ECHA C&L Inventory.

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Note: Most foams will react with the material and release corrosive/toxic gases. SMALL FIRE: CO2, dry chemical, dry sand, alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam. FOR CHLOROSILANES, DO NOT USE WATER; use AFFF alcohol-resistant medium-expansion foam. Move containers from fire area if you can do it without risk. Use water spray or fog; do not use straight streams. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. FOR CHLOROSILANES, use AFFF alcohol-resistant medium-expansion foam to reduce vapors. DO NOT GET WATER on spilled substance or inside containers. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas. SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)

Toxicity

moderately toxic

Drug Information

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death. Contact with molten substance may cause severe burns to skin and eyes. Reaction with water or moist air will release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)

Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

MoCl3

Molybdenum pentachloride Use and Manufacturing

Methods of Manufacturing

Molybdenum metal is directly chlorinated with chlorine gas at 350°C to obtain a finished product of molybdenum pentachloride. 2Mo+5C12→2MC15

Uses

Used as a component of chlorinated catalysts and refractory resins for the preparation of molybdenum hexacarbonyl and metal organic compounds.

Molybdenum chloride (MoCl5): ACTIVE

Fire Hazards -> Corrosives, Reactive - 2nd degree

Computed Properties

Molecular Weight:273.2
Exact Mass:274.746717
Monoisotopic Mass:272.749667
Heavy Atom Count:6
Complexity:37.1
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of Molybdenum pentachloride

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.