    Palladium chloride solid

    ItemsSpecifications
    AppearanceRed-brown crystalline powder
    SolubilityVery soluble in N,N-Dimethylformamide,Soluble in methanol,Sparingly soluble inglacial acetic acid, Very slightly soluble inchloroform, Practically insoluble in water.
    Melting Point152°C~156°C

    Certificates

    Basic Info
    Product Name:

    Diethylene glycol monohexyl ether

    Other Name:

    Ethanol,2-[2-(hexyloxy)ethoxy]-;2-[2-(Hexyloxy)ethoxy]ethanol;Diethylene glycol monohexyl ether;n-Hexoxyethoxyethanol;Hexyl Carbitol;Diethylene glycol hexyl ether;3,6-Dioxa-1-dodecanol;Ucar Filmer EHC;DEGHE;NSC 403666;HEDG;Kyowanol HX 20;Hexyl diglycol;2-(2-Hexoxyethoxy)ethanol

    CAS No.:

    112-59-4

    Molecular Formula:

    C10H22O3

    InChIKeys:

    InChIKey=GZMAAYIALGURDQ-UHFFFAOYSA-N

    Molecular Weight:

    190.28

    Exact Mass:

    190.28

    EC Number:

    203-988-3

    UNII:

    Z6X09N6YJL

    ICSC Number:

    1572

    NSC Number:

    403666

    DSSTox ID:

    DTXSID4026921

    Color/Form:

    Water-white liquid

    HScode:

    29094400

    Characteristics
    PSA:

    38.69000

    XLogP3:

    1.50

    Appearance:

    Diethylene glycol n-hexyl ether is a water-white liquid. (USCG, 1999)

    Density:

    0.935 g/cm3 @ Temp: 25 °C

    Melting Point:

    -40 °C

    Boiling Point:

    259.1 °C @ Press: 760 Torr

    Flash Point:

    >230 °F

    Refractive Index:

    n 20/D 1.4381(lit.)

    Water Solubility:

    H2O: 17g/l;soluble in water. Ethers tend to form unstable peroxides when exposed to oxygen. Ethyl, isobutyl, ethyl tert-butyl, and ethyl tert-pentyl ether are particularly hazardous in this respect. Ether peroxides can sometimes be observed as clear crystals deposited on containers or along the surface of the liquid.

    Vapor Pressure:

    <0.01 hPa (20 °C)

    Vapor Density:

    Relative vapour density (air = 1): 6.6

    Toxicity:

    LD50 orally in Rabbit: 2400 mg/kg LD50 dermal Rabbit 1395 mg/kg

    Explosive limit:

    1.1-6.3%(V)

    Henrys Law Constant:

    Henry's Law constant = 8.9X10-11 atm-cu m/mol at 25 °C (est)

    Experimental Properties:

    1 mg/L = 128.5 ppm at 25 °C, 760 mm Hg; 1 ppm = 7.78 mg/cu m at 25 °C, 760 mm Hg|7.8 lb/gal; freezing point: -33 °C. Combustible|Hydroxyl radical reaction rate constant = 4.04X10-11 cu cm/molec-sec at 25 °C (est)

    Air and Water Reactions:

    Ethers tend to form unstable peroxides when exposed to oxygen. Ethyl, isobutyl, ethyl tert-butyl, and ethyl tert-pentyl ether are particularly hazardous in this respect. Ether peroxides can sometimes be observed as clear crystals deposited on containers or along the surface of the liquid.

    Reactive Group:

    Ethers

    Reactivity Alerts:

    Peroxidizable Compound

    Reactivity Profile:

    Ethers, such as DIETHYLENE GLYCOL N-HEXYL ETHER can act as bases. They form salts with strong acids and addition complexes with Lewis acids. The complex between diethyl ether and boron trifluoride is an example. Ethers may react violently with strong oxidizing agents. In other reactions, which typically involve the breaking of the carbon-oxygen bond, ethers are relatively inert.

    Hazard Identification

    Classification of the substance or mixture

    Acute toxicity - Category 4, Dermal

    Serious eye damage, Category 1

    GHS label elements, including precautionary statements

    Pictogram(s)
    Signal word

    Danger

    Hazard statement(s)

    H312 Harmful in contact with skin

    H318 Causes serious eye damage

    Precautionary statement(s)
    Prevention

    P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...

    Response

    P302+P352 IF ON SKIN: Wash with plenty of water/...

    P317 Get medical help.

    P321 Specific treatment (see ... on this label).

    P362+P364 Take off contaminated clothing and wash it before reuse.

    P305+P354+P338 IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

    Storage

    none

    Disposal

    P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.

    Other hazards which do not result in classification

    no data available

    Handling and Storage

    Precautions for safe handling

    NO open flames. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

    Conditions for safe storage, including any incompatibilities

    Separated from strong oxidants.

  • Seller Information
    Business Type:

    Trader

    Main Products:

    PVC resin,pvc paste resin,melamine

    Location:

    Room 405, Unit 2, Building 1, Taiji Mansion, No. 38, Nanyang Road, Jinshui District, Zhengzhou City, Henan Province

    Payment Terms:

    TT against copy of documents,L/C

    Average lead Time:

    90

    Total Annual Revenue:

    $5 million-$10 million

    Total Employees:

    11-50

    Year of Establishment:

    2022

  • Country Product Purchase Quantity Date Posted
    Post an enquiry for this product
pic ×

Scan the QR Code to Share

All products displayed on this website are only for non-medical purposes such as industrial applications or scientific research, and cannot be used for clinical diagnosis or treatment of humans or animals. They are not medicinal or edible.

According to relevant laws and regulations and the regulations of this website, units or individuals who purchase hazardous materials should obtain valid qualifications and qualification conditions.

The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legitimacy of the content are the responsibility of the publishing company. ECHEMI does not bear any guarantee responsibility for this. Please be aware that risks in internet transactions objectively exist.

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.