ANTIMONY PENTAFLUORIDE 7783-70-2
ISO
7783-70-2
Industrial Grade
99%
25KG/drum
2023-07-31
Flavors & Fragrances,Catalyst & Auxiliary,Intermediates,Dyes & Pigments,Inorganic Chemistry,petro chemicals
-
Product Description
-
Seller Information
-
DescriptionNANTONG REFORM PETRO-CHEMICAL CO.,LTD, with approximately 201447 visits to its shop, is a reputable Manufactory that has been providing ANTIMONY PENTAFLUORIDE 7783-70-2 products for 4 years on ECHEMI.CertificatesBasic Info
-
Product Name:
Antimony pentafluoride
Other Name:Antimony fluoride (SbF5);Antimony pentafluoride;Antimony(V) fluoride;Pentafluoroantimony
CAS No.:7783-70-2
Molecular Formula:F5Sb
InChIKeys:InChIKey=VBVBHWZYQGJZLR-UHFFFAOYSA-I
Molecular Weight:216.75
Exact Mass:215.895844
EC Number:232-021-8
ICSC Number:0220
UN Number:1732
Color/Form:Hygroscopic, moderately viscous liquid|Hygroscopic, viscous liquid|Oily, colorless liquid
HScode:28261990
Categories:
Characteristics-
PSA:
0 Ų
XLogP3:2.10100
Appearance:White to off-white Shiny Flakes or Powder
Density:3.097 g/cm3 @ Temp: 25.8 °C
Melting Point:8.3 °C
Boiling Point:141 °C
Flash Point:149.5°C
Water Solubility:liquid sulfur dioxide: slightly soluble (lit.)
Storage Conditions:Store below +30°C.
Vapor Pressure:10 mm Hg ( 25 °C)
Vapor Density:2.2 (vs air)
Toxicity:Inhalation-Mouse LC50: 270 mg/m3
Flammability characteristics:Decomposes with water to produce corrosive hydrogen fluoride gas, producing hydrofluoric acid; flammable in case of flammable materials; ventilated at low temperature and dry in the warehouse; dry powder, foam, sand, carbon dioxide, and mist water stored separately from food raw materials are flammable; combustion produces toxic fluoride and antimony Chemical smog
Odor:Sharp odor
Experimental Properties:Very reactive|A good oxidizing and fluorinating agent.|Slowly hydrolyzed in sodium hydroxide solution forming antimony hydroxide ion (Sb(OH)6-). Forms solids with sulfur chloride, carbon disulfide, benzene, toluene, petroleum ether, ether, alcohol, acetone, ethyl acetate.|Antimony pentafluoride ... readily replaces all chlorines with fluorine in an organic compound, and fluorinates double bonds and aromatic rings.|For more Other Experimental Properties (Complete) data for Antimony pentafluoride (7 total), please visit the HSDB record page.
Air and Water Reactions:Fumes in air to form small amounts of hydrogen fluoride (reacts with moisture in air). May React with water to give hydrofluoric acid (HF) [Merck 11th ed. 1989]. Based on a scenario where the chemical is spilled into an excess of water (at least 5 fold excess of water), half of the maximum theoretical yield of Hydrogen Fluoride gas will be created in 1.2 minutes. Experimental details are in the following: "Development of the Table of Initial Isolation and Protective Distances for the 2008 Emergency Response Guidebook", ANL/DIS-09-2, D.F. Brown, H.M. Hartmann, W.A. Freeman, and W.D. Haney, Argonne National Laboratory, Argonne, Illinois, June 2009.
Reactive Group:Acids, Strong Non-oxidizing
Reactivity Alerts:Water-Reactive
Reactivity Profile:ANTIMONY PENTAFLUORIDE is strongly acidic. Reacts vigorously with bases. When heated to decomposition, it emits highly toxic fumes of fluorides and metallic antimony. Reacts with ammonia to form a diammoniate.
Corrosivity:Slowly corrodes glass, copper, lead|When moisture is present, causes severe corrosion of metals (except steel) and glass.
Heat of Vaporization:79 Btu/lb = 44 cal/g = 1.8X10+5 J/kg (est)
Hazard IdentificationClassification of the substance or mixture
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 3
GHS label elements, including precautionary statements
Pictogram(s) No symbol. Signal word No signal word
Hazard statement(s) H412 Harmful to aquatic life with long lasting effects
Precautionary statement(s) Prevention P273 Avoid release to the environment.
Response none
Storage none
Disposal P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
Other hazards which do not result in classification
no data available
Handling and StoragePrecautions for safe handling
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Conditions for safe storage, including any incompatibilities
Separated from combustible substances, reducing agents and food and feedstuffs. Dry. Well closed. Keep in a well-ventilated room. Do NOT store or transport in containers made from metal or glass. Provision to contain effluent from fire extinguishing. Store in an area without drain or sewer access.Store in a cool, dry, well-ventilated location. Outside or detached storage is preferred. Separate from organic or siliceous materials.
-
-
Seller Information
-
Business Type:
Manufactory
-
Main Products:
Flavors & Fragrances,Catalyst & Auxiliary,Intermediates,Dyes & Pigments,Inorganic Chemistry,petro chemicals
-
Location:
17th Yuanlin Road ,Chongchuan area ,Nantong city ,Jiangsu province ,China
-
Payment Terms:
L/C,100% TT in advance
-
Average lead Time:
2
-
Total Annual Revenue:
Above $100 million
-
Total Employees:
201-300
-
Year of Establishment:
2008
-
Certifications:
GB/T19001-2016 / Iso9001:2015
-
-
Country Product Purchase Quantity Date Posted Post an enquiry for this product