Product
Supplier
Encyclopedia
Inquiry
Bis(Hexamethylene Triamine Penta (Methylene Phosphonic Acid)) (for water treatment) buy - large image1
Bis(Hexamethylene Triamine Penta (Methylene Phosphonic Acid)) (for water treatment) buy - image1

Bis(Hexamethylene Triamine Penta (Methylene Phosphonic Acid)) (for water treatment)

Unit Price: Get Latest Price
CAS No.:

34690-00-1

Grade:

Industrial Grade

Port:

Shanghai

Packaging:

250KG/Drum

Price valid (until):

2025-05-15

Company Type:
Distributor
Location:
China
Qualification:
Main Products:

Resin,Coating&Ink,Adhesive,Polyurethane,Home&Personal Care,Plastic & Rubber

  • Product Description

  • Seller Information

  • Description

    Technical Data Sheet

    BHMTPMPA is an efficient chelating scale inhibitor with good scale inhibition effect on carbonate scale and sulfate scale.

    BHMTPMPA has excellent water solubility and thermal stability in a wide pH range and at a high temperature of 120°C, and has high tolerance to calcium ions. BHMTPMPA is used as a corrosion and scale inhibitor for oilfield water treatment, and a scale and corrosion inhibitor for industrial circulating cooling water and boiler water

    Items Specifications
    Appearance Dark amber liquid
    Active component/% 45.0~50.0
    Phosphorous acid (as PO33-)/% ≤3.5
    Chloride (as Cl-)/% ≤6.0
    pH (1% aqueous solution) ≤2.0
    Density (20℃) /g·cm-3 ≥1.20
    Fe content (as Fe) /mg·L-1 ≤35.0

    Usage
    Use alone or in combination with polycarboxylic acid scale inhibitors and dispersants.

    Packaging and storage
    BHMTPMPA is packaged in plastic barrels, 25kg per barrel or as required by the user. BHMTPMPA is stored in a cool place indoors for twelve months.

    Safety protection
    BHMTPMPA is acidic. Pay attention to labor protection during operation. Avoid contact with skin, eyes, etc. Rinse with plenty of water after contact.

    Basic Info
    Product Name:

    P,P′,P′′,P′′′-[[(Phosphonomethyl)imino]bis[6,1-hexanediylnitrilobis(methylene)]]tetrakis[phosphonic acid]

    Other Name:

    Phosphonic acid,P,P′,P′′,P′′′-[[(phosphonomethyl)imino]bis[6,1-hexanediylnitrilobis(methylene)]]tetrakis-;Phosphonic acid,[[(phosphonomethyl)imino]bis[6,1-hexanediylnitrilobis(methylene)]]tetrakis-;P,P′,P′′,P′′′-[[(Phosphonomethyl)imino]bis[6,1-hexanediylnitrilobis(methylene)]]tetrakis[phosphonic acid];Triaminodihexylenepentakis(methylenephosphonic acid);Unihib 1704;Lonza 1704;(Dihexyltriaminepenta(methylenephosphonic acid));Briquest 5123-45A;Bis(hexamethylenetriamine)penta(methylenephosphonic acid);Dihexamethylenetriaminepentakis(methylenephosphonic acid);Dequest 2090;BHTPMP;N-(6-Aminohexyl)-1,6-hexanediamine penta(methylene phosphonic acid);120718-90-3

    CAS No.:

    34690-00-1

    Molecular Formula:

    C17H44N3O15P5

    InChIKeys:

    InChIKey=YWMWZKYVGNWJPU-UHFFFAOYSA-N

    Molecular Weight:

    685.41

    Exact Mass:

    685.41

    EC Number:

    252-156-6

    UNII:

    PHO21X9SHC

    DSSTox ID:

    DTXSID9029358

    Categories:

    Water Stabilizer

    Characteristics
    PSA:

    346.42000

    XLogP3:

    0.68920

    Appearance:

    Liquid

    Density:

    1.606 g/cm3

    Boiling Point:

    1002.7ºC at 760 mmHg

    Flash Point:

    560.2ºC

    Refractive Index:

    1.578

    Hazard Identification

    Classification of the substance or mixture

    Corrosive to metals, Category 1

    Skin irritation, Category 2

    Serious eye damage, Category 1

    GHS label elements, including precautionary statements

    Pictogram(s)
    Signal word

    Danger

    Hazard statement(s)

    H290 May be corrosive to metals

    H315 Causes skin irritation

    H318 Causes serious eye damage

    Precautionary statement(s)
    Prevention

    P234 Keep only in original packaging.

    P264 Wash ... thoroughly after handling.

    P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...

    Response

    P390 Absorb spillage to prevent material damage.

    P302+P352 IF ON SKIN: Wash with plenty of water/...

    P321 Specific treatment (see ... on this label).

    P332+P317 If skin irritation occurs: Get medical help.

    P362+P364 Take off contaminated clothing and wash it before reuse.

    P305+P354+P338 IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

    P317 Get medical help.

    Storage

    P406 Store in a corrosion resistant/...container with a resistant inner liner.

    Disposal

    none

    Other hazards which do not result in classification

    no data available

    Handling and Storage

    Precautions for safe handling

    Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

    Conditions for safe storage, including any incompatibilities

    Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.

  • Seller Information
    Business Type:

    Distributor

    Main Products:

    Resin,Coating&Ink,Adhesive,Polyurethane,Home&Personal Care,Plastic & Rubber

    Location:

    12F Huayin Building, NO.5, Donghai West, Road, Qingdao, China

    Payment Terms:

    TT against copy of documents,D/P,L/C,O/A,100% TT in advance

    Average lead Time:

    40

    Total Annual Revenue:

    $2.5 million-$5 million

    Total Employees:

    101-200

    Year of Establishment:

    2007

    ECHEMI Chemical BU provides raw materials covering different industries, CASE, Polyurethane, Home & Personal Care, Plastic & Rubber, etc., serves customers over 110 countries and regions.

    As a bridge connecting chemical producers and end-users, we provide efficient, safe and sustainable chemical service and high-quality products to our customers.

    Service oriented and focusing on key product management, industry basket providing, supply chain optimization. Stick closer to market and customers.


  • Country Product Purchase Quantity Date Posted
    Post an enquiry for this product
pic ×

Scan the QR Code to Share

All products displayed on this website are only for non-medical purposes such as industrial applications or scientific research, and cannot be used for clinical diagnosis or treatment of humans or animals. They are not medicinal or edible.

According to relevant laws and regulations and the regulations of this website, units or individuals who purchase hazardous materials should obtain valid qualifications and qualification conditions.

The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legitimacy of the content are the responsibility of the publishing company. ECHEMI does not bear any guarantee responsibility for this. Please be aware that risks in internet transactions objectively exist.

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.