Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > Dicetyl peroxydicarbonate

Dicetyl peroxydicarbonate

Dicetyl peroxydicarbonate structure

Dicetyl peroxydicarbonate 

structure
  • CAS No:

    26322-14-5

  • Formula:

    C34H66O6

  • Chemical Name:

    Dicetyl peroxydicarbonate

  • Synonyms:

    Peroxydicarbonic acid,C,C′-dihexadecyl ester;Peroxydicarbonic acid,dihexadecyl ester;Dicetyl peroxydicarbonate;Dihexadecyl peroxydicarbonate;Perkadox 24W40;Lupersol 216;Perkadox 24;Liladox;Liladox 33W;Liladox 90P;Perkadox 24FL;Perkadox 24L;Cetyl peroxy dicarbonate;960281-36-1

  • Categories:

    Specialty Chemicals

Description

Dicetyl peroxydicarbonate is a white powder with faint odor. It presents a bulk density of 0.6 g/cm
3
andmelting point of 52°C. It is sensitive to heat and its storage must be done so with stringent temperature control measures. Its explosion hazard is mitigated by mixing the peroxide with inert solid. It decomposes violently or explosively at temperatures 0–10°C owing to self-accelerating exothermic decomposition. Several recorded explosions were due to shock, heat, or friction; amine


This solid peroxide is sensitive to heat. Storage of this material must be done so with stringent temperature control measures. Its explosion hazard is also mitigated by mixing the peroxide with inert solid.


This solid peroxide is sensitive to heat. Storage of this material must be done so with stringent temperature control measures. Its explosion hazard is also mitigated by mixing the peroxide with inert solid.

Dicetyl peroxydicarbonate Basic Attributes

570.88

570.88

247-611-0

XE3V3NKT2E

31163119

DTXSID1051937

2909600000

Characteristics

71.1

12.17040

This solid peroxide is sensitive to heat. Storage of this material must be done so with stringent temperature control measures. Its explosion hazard is also mitigated by mixing the peroxide with inert solid.

0.936 g/cm3

52 °C

592.2ºC at 760 mmHg

237.6ºC

1.458

No rapid reaction with air. No rapid reaction with water.

Peroxides, Organic

Explosive

DICETYL PEROXYDICARBONATE decomposes violently or explosively at temperatures 0-10° C. owing to self-accelerating exothermic decomposition; Several explosions were due to shock, heat or friction; amines and certain metals can cause accelerated decomposition [Bretherick, 1979 p. 156].

Safety Information

II

5.2

UN 2895/2164/2985

P210, P220, P234, P280, P370+P378, P403+P235, P411, P420, P501

H242

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: May explode from heat, contamination or loss of temperature control. These materials are particularly sensitive to temperature rises. Above a given "Control Temperature" they decompose violently and catch fire. May ignite combustibles (wood, paper, oil, clothing, etc.). May ignite spontaneously if exposed to air. May be ignited by heat, sparks or flames. May burn rapidly with flare-burning effect. Containers may explode when heated. Runoff may create fire or explosion hazard. (ERG, 2016)

|Warning|H242 (100%): Heating may cause a fire [Danger Self-reactive substances and mixtures; Organic peroxides]|P210, P220, P234, P280, P370+P378, P403+P235, P411, P420, and P501|Aggregated GHS information provided by 63 companies from 3 notifications to the ECHA C&L Inventory.

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: The temperature of the substance must be maintained at or below the "Control Temperature" at all times. SMALL FIRE: Water spray or fog is preferred; if water not available use dry chemical, CO2 or regular foam. LARGE FIRE: Flood fire area with water from a distance. Use water spray or fog; do not use straight streams. Do not move cargo or vehicle if cargo has been exposed to heat. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. BEWARE OF POSSIBLE CONTAINER EXPLOSION. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. LARGE SPILL: Consider initial evacuation for at least 250 meters (800 feet) in all directions. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch or walk through spilled material. Stop leak if you can do it without risk. SMALL SPILL: Pick up with inert, damp, non-combustible material using clean, non-sparking tools and place into loosely covered plastic containers for later disposal. LARGE SPILL: Dike far ahead of liquid spill for later disposal. Prevent entry into waterways, sewers, basements or confined areas. DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST. (ERG, 2016)

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection. (ERG, 2016)

Drug Information

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: Fire may produce irritating, corrosive and/or toxic gases. Ingestion or contact (skin, eyes) with substance may cause severe injury or burns. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)

Excerpt from ERG Guide 148 [Organic Peroxides (Heat and Contamination Sensitive / Temperature Controlled)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. Contaminated clothing may be a fire risk when dry. Remove material from skin immediately. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. Keep victim calm and warm. (ERG, 2016)

dicetyl dicarbonateperoxide

Dicetyl peroxydicarbonate Use and Manufacturing

Uses

Dicetyl peroxydicarbonate is an imitator for the copolymerization of vinyl chloride, vinylidene chloride, acrylates, and methacrylates. No information was located for this compound. Decomposition or combustion products include carbon dioxide, carbon monoxide, and hexadecanol.

Peroxydicarbonic acid, C,C'-dihexadecyl ester: ACTIVE

Computed Properties

Molecular Weight:570.9
XLogP3:16.5
Hydrogen Bond Acceptor Count:6
Rotatable Bond Count:35
Exact Mass:570.48593982
Monoisotopic Mass:570.48593982
Topological Polar Surface Area:71.1
Heavy Atom Count:40
Complexity:479
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of Dicetyl peroxydicarbonate

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.