Methyl isobutyl ketone peroxide
-
Methyl isobutyl ketone peroxide
structure -
-
CAS No:
37206-20-5
-
Chemical Name:
Methyl isobutyl ketone peroxide
-
Synonyms:
2-Pentanone,4-methyl-,peroxide;Methyl isobutyl ketone peroxide;Trigonox HM 80;Isobutyl methyl ketone peroxide;Kayamek B;MIKP-NA 1;MI 60K;Trigonox 233;Trigonox HMS;Peroxan MI 60KX;Curox I 300;XY-KG 876;37232-19-2;37307-66-7;58318-13-1
- Categories:
-
CAS No:
Description
Methyl isobutyl ketone peroxide appears as a colorless liquid shipped with not more than 62% peroxide in solution of methyl isobutyl ketone. Crystallizes when dry. May explode from heat, shock or friction when dry.
Methyl isobutyl ketone peroxide appears as a colorless liquid shipped with not more than 62% peroxide in solution of methyl isobutyl ketone. Crystallizes when dry. May explode from heat, shock or friction when dry.
Methyl isobutyl ketone peroxide Basic Attributes
234.33244
132.078644241 g/mol
253-396-4
3105
DTXSID9067356
Characteristics
57.53000
1.63890
No rapid reaction with air. No rapid reaction with water.
Ketones
Explosive
Peroxides, such as METHYL ISOBUTYL KETONE PEROXIDE, are good oxidizing agents. Organic compounds can ignite on contact with concentrated peroxides. Strongly reduced material such as sulfides, nitrides, and hydrides may react explosively with peroxides. There are few chemical classes that do not at least produce heat when mixed with peroxides. Many produce explosions or generate gases (toxic and nontoxic). Generally, dilute solutions of peroxides (<70%) are safe, but the presence of a catalyst (often a transition metal such as cobalt, iron, manganese, nickel, or vanadium) as an impurity may even then cause rapid decomposition, a buildup of heat, and even an explosion. Solutions of peroxides often become explosive when evaporated to dryness or near-dryness. May explode from heat or contamination. May explode from heat, shock, friction or contamination. May ignite combustibles (wood, paper, oil, clothing, etc.). May be ignited by heat, sparks or flames. May burn rapidly with flare-burning effect.
Safety Information
II
5.2
3105
Excerpt from ERG Guide 145 [Organic Peroxides (Heat and Contamination Sensitive)]: May explode from heat or contamination. May ignite combustibles (wood, paper, oil, clothing, etc.). May be ignited by heat, sparks or flames. May burn rapidly with flare-burning effect. Containers may explode when heated. Runoff may create fire or explosion hazard. (ERG, 2016)
|Danger|H242 (100%): Heating may cause a fire [Danger Self-reactive substances and mixtures; Organic peroxides]|P210, P220, P234, P261, P264, P270, P271, P272, P280, P301+P312, P302+P352, P304+P312, P304+P340, P305+P351+P338, P310, P311, P312, P321, P330, P332+P313, P333+P313, P337+P313, P362, P363, P370+P378, P403+P233, P403+P235, P405, P411, P420, and P501|Aggregated GHS information provided by 9 companies from 4 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.|H226 (100%): Flammable liquid and vapor [Warning Flammable liquids]|P210, P220, P233, P234, P240, P241, P242, P243, P260, P261, P264, P270, P271, P272, P273, P280, P301+P310, P301+P312, P301+P330+P331, P302+P352, P303+P361+P353, P304+P312, P304+P340, P305+P351+P338, P310, P312, P321, P330, P331, P333+P313, P363, P370+P378, P391, P403+P235, P405, P411, P420, and P501|Aggregated GHS information provided by 10 companies from 1 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Excerpt from ERG Guide 145 [Organic Peroxides (Heat and Contamination Sensitive)]: SMALL FIRE: Water spray or fog is preferred; if water not available use dry chemical, CO2 or regular foam. LARGE FIRE: Flood fire area with water from a distance. Use water spray or fog; do not use straight streams. Do not move cargo or vehicle if cargo has been exposed to heat. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)
Excerpt from ERG Guide 145 [Organic Peroxides (Heat and Contamination Sensitive)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. LARGE SPILL: Consider initial evacuation for at least 250 meters (800 feet) in all directions. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)
Excerpt from ERG Guide 145 [Organic Peroxides (Heat and Contamination Sensitive)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep substance wet using water spray. Stop leak if you can do it without risk. SMALL SPILL: Pick up with inert, damp, non-combustible material using clean, non-sparking tools and place into loosely covered plastic containers for later disposal. LARGE SPILL: Wet down with water and dike for later disposal. Prevent entry into waterways, sewers, basements or confined areas. DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST. (ERG, 2016)
Excerpt from ERG Guide 145 [Organic Peroxides (Heat and Contamination Sensitive)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection. (ERG, 2016)
Drug Information
Excerpt from ERG Guide 145 [Organic Peroxides (Heat and Contamination Sensitive)]: Fire may produce irritating, corrosive and/or toxic gases. Ingestion or contact (skin, eyes) with substance may cause severe injury or burns. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)
Excerpt from ERG Guide 145 [Organic Peroxides (Heat and Contamination Sensitive)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. Contaminated clothing may be a fire risk when dry. Remove material from skin immediately. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. Keep victim calm and warm. (ERG, 2016)
Methyl isobutyl ketone peroxide Use and Manufacturing
2-Pentanone, 4-hydroperoxy-4-methyl-: INACTIVE
Computed Properties
Molecular Weight:132.16
XLogP3:-0.1
Hydrogen Bond Donor Count:1
Hydrogen Bond Acceptor Count:3
Rotatable Bond Count:3
Exact Mass:132.078644241
Monoisotopic Mass:132.078644241
Topological Polar Surface Area:46.5
Heavy Atom Count:9
Complexity:107
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes
Recommended Suppliers of Methyl isobutyl ketone peroxide
-
CN
5 YRS
Business licensed Certified factoryManufactory Supplier of Agrochemicals,Daily Chemicals,Catalysts & Chemical Auxiliary Agents,Extract,Inorganic Chemicals,Organic Intermediate,Pigment & Dyestuff,Polymer,Flavour & Fragrance,Basic Organic Chemicals,PharmaceuticalInquiryCAS No.: 37206-20-5Grade: Industrial GradeContent: 99% -
CN
4 YRS
Business licensedTrader Supplier of Organic Peroxide,Azo InitiatorsInquiryCAS No.: 37206-20-5Grade: Industrial GradeContent: 62%
Learn More Other Chemicals
-
Methyl isobutyl ketone
108-10-1
-
4-BroMophenyl-d4 Methyl Ketone
343942-02-9
-
2-Methylcyclopropyl methyl ketone
930-56-3
-
Cyclopropyl methyl ketone Formula
765-43-5
-
Cyclobutyl methyl ketone Formula
3019-25-8
-
Butyl methyl ketone oxime Formula
5577-48-0
-
Isobutyl phenyl ketone Structure
582-62-7
-
Cyclohexyl methyl ketone Structure
823-76-7
-
What is Isobutyl ketone
108-83-8
-
What is Methyl ethyl ketone
78-93-3