Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > tert-Butylperoxy isopropyl carbonate

tert-Butylperoxy isopropyl carbonate

tert-Butylperoxy isopropyl carbonate structure

tert-Butylperoxy isopropyl carbonate 

structure
  • CAS No:

    2372-21-6

  • Formula:

    C8H16O4

  • Chemical Name:

    tert-Butylperoxy isopropyl carbonate

  • Synonyms:

    Carbonoperoxoic acid,OO-(1,1-dimethylethyl) O-(1-methylethyl) ester;Peroxycarbonic acid,OO-tert-butyl O-isopropyl ester;tert-Butylperoxy isopropyl carbonate;Lupersol TBIC;OO-tert-Butyl O-isopropyl percarbonate;Kayacarbon BIC;Lupersol TBIC-M 75;Perbutyl I;Trigonox BPIC;OO-tert-Butyl O-isopropyl peroxycarbonate;Trigonox 149;Luperox TBIC-M 75;Triginox BPIC;BIC 75;Kayacarbon BIC 75;Trigonox BPIC-C 75;Perbutyl I 75;TBIC;TBIC-M 75;BPIC-C 75;Luperox TBIC;155420-96-5

  • Categories:

    Pharmaceutical Intermediates  >  Bulk Drug Intermediates

Description

clear solution


Sensitive to heat. Must be stored with stringent maintenance of low temperature.|Liquid


Sensitive to heat. Must be stored with stringent maintenance of low temperature.

tert-Butylperoxy isopropyl carbonate Basic Attributes

176.21000

176.21

219-143-7

3103

2918300090

Characteristics

44.76000

2.27810

Sensitive to heat. Must be stored with stringent maintenance of low temperature.

0.994 g/cm3

-20ºC

170.8ºC at 760 mmHg

57.6ºC

n20/D 1.448

No rapid reaction with air. No rapid reaction with water.

Esters, Sulfate Esters, Phosphate Esters, Thiophosphate Esters, and Borate Esters

Explosive

TERT-BUTYL PEROXYISOPROPYL CARBONATE is a oxidizing agent. Decomposes violently or explosively at temperatures 0-10°C owing to self- accelerating exothermic decomposition; Several explosions were due to shock, heat or friction. Amines and certain metals can accelerate decomposition [Bretherick 1979 p. 151].

Safety Information

II

5.2

UN 3103

R7

36/37/39-35-3/7-26-14A-14-62-45-53

Xi: Irritant;T: Toxic;O: Oxidizing agent;E: Explosive;

P210, P220, P233, P234, P240, P241, P242, P243, P261, P264, P272, P273, P280, P302+P352, P303+P361+P353, P305+P351+P338, P310, P321, P332+P313, P333+P313, P362, P363, P370+P378, P370+P380+P375, P391, P403+P235, P411, P420, P501

H226

Excerpt from ERG Guide 146 [Organic Peroxides (Heat, Contamination and Friction Sensitive)]: May explode from heat, shock, friction or contamination. May ignite combustibles (wood, paper, oil, clothing, etc.). May be ignited by heat, sparks or flames. May burn rapidly with flare-burning effect. Containers may explode when heated. Runoff may create fire or explosion hazard. (ERG, 2016)

|Danger|H226 (86.36%): Flammable liquid and vapor [Warning Flammable liquids]|P210, P220, P233, P234, P240, P241, P242, P243, P261, P264, P272, P273, P280, P302+P352, P303+P361+P353, P305+P351+P338, P310, P321, P332+P313, P333+P313, P362, P363, P370+P378, P370+P380+P375, P391, P403+P235, P411, P420, and P501|Aggregated GHS information provided by 44 companies from 4 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Excerpt from ERG Guide 146 [Organic Peroxides (Heat, Contamination and Friction Sensitive)]: SMALL FIRE: Water spray or fog is preferred; if water not available use dry chemical, CO2 or regular foam. LARGE FIRE: Flood fire area with water from a distance. Use water spray or fog; do not use straight streams. Do not move cargo or vehicle if cargo has been exposed to heat. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)

Excerpt from ERG Guide 146 [Organic Peroxides (Heat, Contamination and Friction Sensitive)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. LARGE SPILL: Consider initial evacuation for at least 250 meters (800 feet) in all directions. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 146 [Organic Peroxides (Heat, Contamination and Friction Sensitive)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep substance wet using water spray. Stop leak if you can do it without risk. SMALL SPILL: Pick up with inert, damp, non-combustible material using clean, non-sparking tools and place into loosely covered plastic containers for later disposal. LARGE SPILL: Wet down with water and dike for later disposal. Prevent entry into waterways, sewers, basements or confined areas. DO NOT CLEAN-UP OR DISPOSE OF, EXCEPT UNDER SUPERVISION OF A SPECIALIST. (ERG, 2016)

Excerpt from ERG Guide 146 [Organic Peroxides (Heat, Contamination and Friction Sensitive)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection. (ERG, 2016)

Drug Information

Excerpt from ERG Guide 146 [Organic Peroxides (Heat, Contamination and Friction Sensitive)]: Fire may produce irritating, corrosive and/or toxic gases. Ingestion or contact (skin, eyes) with substance may cause severe injury or burns. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)

Excerpt from ERG Guide 146 [Organic Peroxides (Heat, Contamination and Friction Sensitive)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. Contaminated clothing may be a fire risk when dry. Remove material from skin immediately. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. Keep victim calm and warm. (ERG, 2016)

tert-Butylperoxy isopropyl carbonate Use and Manufacturing

Uses

Fillers

Miscellaneous manufacturing|Carbonoperoxoic acid, OO-(1,1-dimethylethyl) O-(1-methylethyl) ester: ACTIVE

Computed Properties

Molecular Weight:176.21
XLogP3:2.4
Hydrogen Bond Acceptor Count:4
Rotatable Bond Count:5
Exact Mass:176.10485899
Monoisotopic Mass:176.10485899
Topological Polar Surface Area:44.8
Heavy Atom Count:12
Complexity:146
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of tert-Butylperoxy isopropyl carbonate

Scan the QR Code to Share

Feedback & Suggestions