Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > 3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?)

3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?)

3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?) structure

3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?) 

structure
  • CAS No:

    2820-51-1

  • Formula:

    C10H14N2.xClH

  • Chemical Name:

    3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?)

  • Synonyms:

    Pyridine,3-[(2S)-1-methyl-2-pyrrolidinyl]-,hydrochloride (1:?);Nicotine,hydrochloride;Pyridine,3-(1-methyl-2-pyrrolidinyl)-,hydrochloride,(S)-;Pyridine,3-[(2S)-1-methyl-2-pyrrolidinyl]-,hydrochloride;3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?)

Description

NICOTINE HYDROCHLORIDE is a white crystalline solid. Combustible, although ignition may be difficult. Toxic by inhalation (dust, etc.) and skin absorption. Produces toxic oxides of nitrogen during combustion.


Nicotine hydrochloride appears as a white crystalline solid. Combustible, although ignition may be difficult. Toxic by inhalation (dust, etc.) and skin absorption. Produces toxic oxides of nitrogen during combustion.


Nicotine hydrochloride appears as a white crystalline solid. Combustible, although ignition may be difficult. Toxic by inhalation (dust, etc.) and skin absorption. Produces toxic oxides of nitrogen during combustion.

3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?) Basic Attributes

198.69200

198.09200

ELZ2L53YNE

1656

DTXSID6020931

Colorless oil

Characteristics

16.13000

2.58820

Nicotine hydrochloride appears as a white crystalline solid. Combustible, although ignition may be difficult. Toxic by inhalation (dust, etc.) and skin absorption. Produces toxic oxides of nitrogen during combustion.

DENSITY 1.0337 /D-FORM/

101.7ºC

All salts are soluble in water, alcohol, and ether /Nicotine salts/

Soluble in water.

Amines, Phosphines, and Pyridines

The chloride salt of nicotine-An alkaloid produced from tobacco. Colorless, oily liquid, combustible, highly toxic. When heated to decomposition it emits very toxic fumes of carbon monoxide and oxides of nitrogen [Lewis, 3rd ed., 1993, p. 919].

Safety Information

II

6.1(a)

UN 1656

Generators of waste (equal to or greater than 100 kg/mo) containing this contaminant, EPA hazardous waste number P075, must conform with USEPA regulations in storage, transportation, treatment and disposal of waste.|A potential candidate for rotary kiln incineration at a temperature range of 820 to 1,600 °C and residence times of seconds for liquids and gases, and hours for solids.|A potential candidate for fluidized bed incineration at a temperature range of 450 to 980 °C and residence times of seconds for liquids and gases, and longer for solids.

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Containers may explode when heated. Runoff may pollute waterways. (ERG, 2016)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Cover with plastic sheet to prevent spreading. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2016)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)|Wear appropriate chemical protective gloves, boots and goggles.|SRP: Contaminated protective clothing should be segregated in such a manner so that there is no direct personal contact by personnel who handle, dispose, or clean the clothing. Quality assurance to ascertain the completeness of the cleaning procedures should be implemented before the decontaminated protective clothing is returned for reuse by the workers. Contaminated clothing should not be taken home at end of shift, but should remain at employee's place of work for cleaning.

Wear positive-pressure self-contained breathing apparatus when fighting fires involving this material.|If material is on fire or involved in a fire: Extinguish fire using agent suitable for type of surrounding fire. Material itself does not burn or burns with difficulty. Use water in flooding quantities of fog. Use foam, dry chemical, or carbon dioxide.

Avoid breathing dusts, and fumes from burning material. Keep upwind. Avoid bodily contact with the material. ... Do not handle broken packages unless wearing appropriate personal protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. ... If contact with the material is anticipated, wear appropriate chemical protective clothing.|If material is not on fire and not involved in a fire: Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers.

/GUIDE 151: SUBSTANCES - TOXIC (NON-COMBUSTIBLE)/ Health: Highly toxic, may be fatal if inhaled, swallowed or absorbed through skin. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. /Nicotine hydrochloride; Nicotine hydrochloride, liquid; Nicotine hydrochloride, solid; Nicotine hydrochloride, solution/|/GUIDE 151: SUBSTANCES - TOXIC (NON-COMBUSTIBLE)/ Fire or Explosion: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Containers may explode when heated. Runoff may pollute waterways. /Nicotine hydrochloride; Nicotine hydrochloride, liquid; Nicotine hydrochloride, solid; Nicotine hydrochloride, solution/|/GUIDE 151: SUBSTANCES - TOXIC (NON-COMBUSTIBLE)/ Public Safety: CALL Emergency Response Telephone Number ... As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at lease 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind. Keep out of low areas. /Nicotine hydrochloride; Nicotine hydrochloride, liquid; Nicotine hydrochloride, solid; Nicotine hydrochloride, solution/|/GUIDE 151: SUBSTANCES - TOXIC (NON-COMBUSTIBLE)/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. /Nicotine hydrochloride; Nicotine hydrochloride, liquid; Nicotine hydrochloride, solid; Nicotine hydrochloride, solution/|For more DOT Emergency Guidelines (Complete) data for NICOTINE HYDROCHLORIDE (8 total), please visit the HSDB record page.

No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./|The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials.|The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article.

P075; An acute hazardous waste when a discarded commercial chemical product or manufacturing chemical intermediate or an off-specification commercial chemical product or a manufacturing chemical intermediate.

Persons in charge of vessels or facilities are required to notify the National Response Center (NRC) immediately, when there is a release of this designated hazardous substance, in an amount equal to or greater than its reportable quantity of 100 lb or 45.4 kg. The toll free number of the NRC is (800) 424-8802. The rule for determining when notification is required is stated in 40 CFR 302.4 (section IV. D.3.b). /Nicotine and salts/

P075; As stipulated in 40 CFR 261.33, when nicotine and salts, as a commercial chemical product or manufacturing chemical intermediate or an off-specification commercial chemical product or a manufacturing chemical intermediate, becomes a waste, it must be managed according to federal and/or state hazardous waste regulations. Also defined as a hazardous waste is any container or inner liner used to hold this waste or any residue, contaminated soil, water, or other debris resulting from the cleanup of a spill, into water or on dry land, of this waste. Generators of small quantities of this waste may qualify for partial exclusion from hazardous waste regulations (40 CFR 261.5(e)). /Nicotine and salts/

Toxicity

LD50 Mouse ip 13,500 mg/kg|LD50 Mouse sc 31,900 ug/kg

Drug Information

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Highly toxic, may be fatal if inhaled, swallowed or absorbed through skin. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Nicotine and Related Compounds/|Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Aggressive airway management may be needed. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Anticipate seizures and treat if necessary... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. Administer activated charcoal ... . /Nicotine and Related Compounds/|Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious or is in respiratory distress. Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start IV administration of D5W /SRP: "To keep open", minimal flow rate/. Use 0.9% saline (NS) or lactated Ringer's (LR) if signs of hypovolemia are present. For hypotension with signs of hypovolemia, administer fluid cautiously. Watch for signs of fluid overload ... . Treat seizures with diazepam or lorazepam ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Nicotine and Related Compounds/|Emergency and supportive measures: Maintain an open airway and assist ventilation if necessary. Administer supplemental oxygen. Treat seizures, coma, hypotension, hypertension, and arrhythmias if they occur. observe for at least 4-6 hours to rule out delayed toxicity, especially after skin exposure. For ingestion of intact gum tablets or transdermal patches, observe for a longer period (up to 12-24 hours). /Nicotine/|For more Antidote and Emergency Treatment (Complete) data for NICOTINE HYDROCHLORIDE (7 total), please visit the HSDB record page.

/HUMAN EXPOSURE STUDIES/ An iv dose of 1.0 mg nicotine hydrochloride ... given to 4 volunteers produced vasoconstriction of the skin and slight to moderate increase of respirations, heart rate, and blood pressure without any serious toxic effect.

3-[(2S)-1-Methyl-2-pyrrolidinyl]pyridine hydrochloride (1:?) Use and Manufacturing

Methods of Manufacturing

By action of respective acid on alkaloid. /Nicotine salts/

Nicotine hydrochloride solution

Computed Properties

Molecular Weight:198.69
Hydrogen Bond Donor Count:1
Hydrogen Bond Acceptor Count:2
Rotatable Bond Count:1
Exact Mass:198.0923762
Monoisotopic Mass:198.0923762
Topological Polar Surface Area:16.1
Heavy Atom Count:13
Complexity:147
Defined Atom Stereocenter Count:1
Covalently-Bonded Unit Count:2
Compound Is Canonicalized:Yes

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.