Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > Propyltrichlorosilane

Propyltrichlorosilane

Propyltrichlorosilane structure

Propyltrichlorosilane 

structure
  • CAS No:

    141-57-1

  • Formula:

    C3H7Cl3Si

  • Chemical Name:

    Propyltrichlorosilane

  • Synonyms:

    Silane,trichloropropyl-;Trichloropropylsilane;Propyltrichlorosilane;Trichloro-n-propylsilane;n-Propyltrichlorosilane;NSC 93878;Dynasylan PTCS

  • Categories:

    Chemical Reagents  >  Organic Reagents

Description

Colorless clear liquidA colorless liquid with a pungent odor. Flash point 100°F. Corrosive to metals and tissue.


Propyltrichlorosilane appears as a colorless liquid with a pungent odor. Corrosive to metals and tissue.|Liquid


Propyltrichlorosilane appears as a colorless liquid with a pungent odor. Corrosive to metals and tissue.

Propyltrichlorosilane Basic Attributes

177.53

177.53

1734990

205-489-6

X16G85FI4Y

93878

1816

Liquid|COLORLESS LIQUID

29319000

Characteristics

0

5.25

Propyltrichlorosilane appears as a colorless liquid with a pungent odor. Corrosive to metals and tissue.

1.195 g/cm3 @ Temp: 20 °C

<0°C

123.5 °C

105 °F

n 20/D 1.430(lit.)

SOL IN WATER

All containers, pipes, apparatus, installations, and structures used for the manufacture, storage, transport, or use of these substances must be of material resistant to corrosive substances or be protected by suitable coatings ... All containers or receptacles should be clearly labelled to indicate their contents and should bear the danger symbol for corrosives. /Corrosive substances/

28.8 mm Hg at 20 deg C

6.15 (Air = 1)

Inflammable in case of open flame, high temperature, oxidant; produces toxic and corrosive chloride gas when heated or in water

Lower explosive limit: 3.4%; Upper explosive limit: > or = 9.5%

ACRID ODOR

Will react with water or steam to produce toxic and corrosive fumes; can react with oxidizing materials|Readily hydrolyzed with liberation of hydrochloric acid.|The reaction of organosilanes with halogens and halogen compounds usually proceeds in good yield through cleavage of the Si--H bond and formation of the silicon-halogen bond. Reaction with fluorine, however, does not proceed satisfactorily because of cleavage of not only the Si--H but also C--Si and C--H bonds. Direct halogenation with chlorination, bromine, and iodine proceeds smoothly, however. /Organosilanes/

Fumes in air. Highly flammable. Gives off HCl gas on contact with moist air. Reacts violently with water, steam, with generation of heat and combustible (H2) and corrosive (HCl) gases [Handling Chemicals Safely 1980 p. 924]. Propyltrichlorosilane reacts vigorously with water to generate gaseous HCl. Based on a scenario where the chemical is spilled into an excess of water (at least 5 fold excess of water), half of the maximum theoretical yield of Hydrogen Chloride gas will be created in 2.1 minutes. After mixing particular chemicals into water, there may be a delay of <1-10 minutes before gas generation may be observed. For this chemical, a 5 second induction time was observed. Experimental details are in the following: "Development of the Table of Initial Isolation and Protective Distances for the 2008 Emergency Response Guidebook", ANL/DIS-09-2, D.F. Brown, H.M. Hartmann, W.A. Freeman, and W.D. Haney, Argonne National Laboratory, Argonne, Illinois, June 2009.

Chlorosilanes

Highly Flammable

PROPYL TRICHLOROSILANE reacts violently with water, steam, moist air, alcohols, acetone, and light metals with generation of heat and flammable (H2) and corrosive (HCl) gases.

Corrosive

Safety Information

II

8

UN 1816 8/PG 2

1

10-14-34

26-36/37/39-43-45

VV5300000

C

Treasury is ventilated, low temperature and dry; stored separately from oxidant

P210, P233, P240, P241, P242, P243, P260, P261, P264, P270, P271, P280, P301+P312, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P311, P321, P330, P363, P370+P378, P403+P233, P403+P235, P405, P501

H226

SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal and plant life; and conformance with environmental and public health regulations.

Reacts with surface moisture to form hydrogen chloride, which is corrosive to common metals.|Can react with oxidizing materials.|Reacts with water to form hydrochloric acid.|React with water or steam to produce heat and toxic and corrosive fumes of HCl. /Chlorosilanes/|With a little ammonia, it forms a self-igniting product. /Chlorosilanes/

Excerpt from ERG Guide 155 [Substances - Toxic and/or Corrosive (Flammable / Water-Sensitive)]: HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapors may travel to source of ignition and flash back. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water. (ERG, 2016)|Corrosives, Flammable - 3rd degree, Reactive - 1st degree

|Danger|H226 (100%): Flammable liquid and vapor [Warning Flammable liquids]|P210, P233, P240, P241, P242, P243, P260, P261, P264, P270, P271, P280, P301+P312, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P311, P321, P330, P363, P370+P378, P403+P233, P403+P235, P405, and P501|Aggregated GHS information provided by 76 companies from 7 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Excerpt from ERG Guide 155 [Substances - Toxic and/or Corrosive (Flammable / Water-Sensitive)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 1816 datasheet. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 155 [Substances - Toxic and/or Corrosive (Flammable / Water-Sensitive)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. FOR CHLOROSILANES, use AFFF alcohol-resistant medium-expansion foam to reduce vapors. DO NOT GET WATER on spilled substance or inside containers. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas. SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2016)

Excerpt from ERG Guide 155 [Substances - Toxic and/or Corrosive (Flammable / Water-Sensitive)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)|Those who have to handle ... /chlorosilanes/ should wear goggles and if necessary a /NIOSH approved respirator/. Handling should be done as far as possible under suitably ventilated hoods. /Chlorosilanes/|Acid-vapor type respiratory protection; rubber gloves; chemical worker's goggles; other protective equipment as necessary to protect eyes and skin.|Where ... /closed-circuit apparatus/ is not possible ... rely on suitable personal protective equipment. Such equipment should ... comprise: corrosion-resistant and impervious suits or overalls, foot protection, hand and arm protection, head, ... eye, and face protection; where corrosive gases /are/ expected, appropriate respiratory protective equipment is required, ranging from simple respirators to air or oxygen lines or self-contained breathing apparatus, coupled with gas-tight goggles ... No universally suitable material for ... personal equipment can be indicated, but ... natural rubbers, synthetic rubbers, polyvinyl chloride, polypropylene, or polyethylene either in sheet form or with fabric backing are suitable. Where aprons are used ... these should have bibs; sleeves should be worn outside gauntlets or gloves and ... trouser legs should cover tops of shoes in order to prevent splashes .... /Corrosive substances/

Flammable liquid.|A dangerous fire hazard when exposed to heat or flame.|Self-ignites in air. With a little ammonia, it forms a self-igniting product. /Chlorosilanes/|Certain strong corrosives may, on contact with organic matter or other chemicals, cause fire ... /Corrosive substances/

Lower explosive limit: 3.4%; Upper explosive limit: > or = 9.5%

If material on fire or involved in fire: use dry chemical, dry sand, or carbon dioxide; do not use water on material itself; if large quantities of combustibles are involved, use water in flooding quantities as spray and fog; use water spray to knock down vapors; cool all affected containers with flooding quantities of water; apply water from as far a distance as possible.|Use water spray, dry chemical, or carbon dioxide to extinguish small fires. Use water to keep fire-exposed containers cool. Approach fire from upwind to avoid hazardous vapors and toxic decomposition products.|Wear special protective clothing and positive pressure self-contained breathing apparatus.

Will react with water or steam to produce toxic and corrosive fumes.

SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a permitted wastewater treatment facility is acceptable only after review by the governing authority and assurance that "pass through" violations will not occur. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must be evaluated in accordance with EPA 40 CFR Part 261, specifically Subpart B, in order to determine the appropriate local, state and federal requirements for disposal.|Eliminate all ignition sources. Stop or control the leak, if this can be done without undue risk. Use water spray to cool and disperse vapors and protect personnel. Spills can be neutralized by flushing with large quantities of water followed by treatment with sodium bicarbonate. Control runoff and isolate discharged material for proper disposal.|Environmental considerations - land spill: dig a pit, pond, lagoon, holding area to contain liquid or solid material /SRP: If time permits, pits, ponds, lagoons, soak holes, or holding areas should be sealed with an impermeable flexible membrane liner/; dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete; absorb bulk liquid with fly ash, cement powder, or commercial sorbents.|Environmental considerations - water spill: use natural barriers or oil spill control booms to limit spill travel; remove trapped material with suction hoses.|Environmental considerations - air spill: apply water spray or mist to knock down vapors.

SRP: The scientific literature for the use of contact lenses by industrial workers is inconsistent. The benefits or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.|SRP: Contaminated protective clothing should be segregated in a manner that results in no direct personal contact by personnel who handle, dispose of, or clean the clothing. Quality assurance procedures to confirm the efficacy of the cleaning procedures should be implemented prior to the decontaminated protective clothing being returned for reuse by the workers. Contaminated clothing (including shoes/socks) should not be taken home at end of shift, but should remain at employee's place of work for cleaning.|SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants. Ensure that the local ventilation moves the contaminant away from the worker.|If material not on fire and not involved in fire: keep sparks, flames, and othr sources of ignition away; keep material out of water sources and sewers; build dikes to contain flow as necessary; use water spray to knock down vapors; do not use water on material itself; neutralize spilled material with crushed limestone soda ash, or lime.|For more Preventive Measures (Complete) data for Trichloropropylsilane (6 total), please visit the HSDB record page.

If ... THERE IS NO FIRE, go directly to the Table of Initial Isolation and Protective Action Distances /(see table below)/ ... to obtain initial isolation and protective action distances. IF THERE IS A FIRE, or IF A FIRE IS INVOLVED, go directly to the appropriate guide /(see guide(s) below)/ and use the evacuation information shown under PUBLIC SAFETY. /Propyltrichlorosilane (when spilled in water)/|Table of Water-Reactive Materials Which Produce Toxic Gases|/GUIDE 155: SUBSTANCES - TOXIC AND/OR CORROSIVE (FLAMMABLE/WATER-SENSITIVE)/ Fire or Explosion: HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapors may travel to source of ignition and flash back. Those substances designated with a "P" may polymerize explosively when heated or involved in a fire. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water.|/GUIDE 155: SUBSTANCES - TOXIC AND/OR CORROSIVE (FLAMMABLE/WATER-SENSITIVE)/ Health: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns, or death. ... Reaction with water or moist air will release toxic, corrosive or flammable gases. Reaction with water may generate much heat which will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution.|For more DOT Emergency Guidelines (Complete) data for Trichloropropylsilane (10 total), please visit the HSDB record page.

No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./|The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials.|The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article.

Irritating to eyes, nose, and throat. Harmful if inhaled.|/SRP: All chlorosilanes release hydrogen chloride in the presence of water/water vapor./ All the chlorosilanes were found to cause severe damage of the cornea and lids. More severe damage was caused by the alkylchlorosilanes than by tetrachlorosilane (silicone tetrachloride). The principal danger is from splash contamination. /Chlorosilanes/|A skin and severe eye irritant.|Causes severe eye and skin burns. Serious health hazard. May be harmful if inhaled. Irritating to eye, skin, and respiratory system. /Dimethylchlorosilane/|Hazard warning: the vapors have adequate warning properties of irritation of the eye, nose, and respiratory passages before sufficient exposure occurs to cause injury to the eyes. The principal danger is from splash contamination. /Chlorosilanes/

| 3 - Materials that, under emergency conditions, can cause serious or permanent injury.| 3 - Liquids and solids that can be ignited under almost all ambient temperature conditions. Materials produce hazardous atmospheres with air under almost all ambient temperatures or, though unaffected by ambient temperatures, are readily ignited under almost all conditions.| 1 - Materials that in themselves are normally stable but that can become unstable at elevated temperatures and pressures.

D002; A waste containing propyltrichlorosilane may (or may not) be characterized a hazardous waste following testing for corrosivity characteristics as prescribed by the Resource Conservation and Recovery Act (RCRA) regulations.

D002; A solid waste containing propyltrichlorosilane may become characterized as a hazardous waste when subjected to testing for corrosivity as stipulated in 40 CFR 261.21, and if so characterized, must be managed as a hazardous waste.

Toxicity

LC50 Rat inhalation 1352 ppm for 1 hr (95% confidence limits 1254-1455 ppm)

Chlorosilane compounds' production and use as intermediates for silicone products may result in their release to the environment through various waste streams. However, these compounds decompose to release hydrogen chloride upon contact with water or steam. Therefore, volatilization, biodegradation, and bioconcentration are not expected to be important environmental fate processes. /Chlorosilanes/ (SRC)

Silane compounds decompose upon contact with water or steam to produce heat and toxic and corrosive fumes of hydrogen chloride. Silane ignites spontaneously in air(1,2). With a little ammonia, it forms a self-igniting product(1). /Chlorosilanes/

According to the 2006 TSCA Inventory Update Report, the number of persons reasonably likely to be exposed in the industrial manufacturing, processing, and use for trichloropropylsilane is 100-999; the data may be greatly underestimated(1).

Drug Information

... Chlorosilanes will be rapidly hydrolyzed upon contact with tissue fluids to release hydrochloric acid. /Chlorosilanes/

Excerpt from ERG Guide 155 [Substances - Toxic and/or Corrosive (Flammable / Water-Sensitive)]: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death. Bromoacetates and chloroacetates are extremely irritating/lachrymators. Reaction with water or moist air will release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)

Excerpt from ERG Guide 155 [Substances - Toxic and/or Corrosive (Flammable / Water-Sensitive)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Silane, Chlorosilane, and Related Compounds/|Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Anticipate seizures and treat if necessary ... . Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. Administer activated charcoal (refer to ingestion protocol in Section Three ... . Cover skin burns with sterile dressings after decontamination ... . /Silane, Chlorosilane, and Related Compounds/|Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious, has severe pulmonary edema, or is in severe respiratory distress. Early intubation at the first sign of upper airway obstruction may be necessary. Positive-pressure ventilation techniques with a bag-valve-mask device may be beneficial. Consider drug therapy for pulmonary edema ... . Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start IV administration of D5W /SRP: "To keep open", minimal flow rate/. Use 0.9% saline (NS) or lactated Ringer's (LR) if signs of hypovolemia are present. For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors if patient is hypotensive with a normal fluid volume. Watch for signs of fluid overload ... . Treat seizures with diazepam or lorazepam ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Silane, Chlorosilane, and related compounds/

/SIGNS AND SYMPTOMS/ Acute inhalation exposure may result in sneezing, choking, laryngitis, dyspnea (shortness of breath), respiratory tract irritation, and chest pain. Higher exposure can cause pulmonary edema, a medical emergency that can be delayed for several hours. This can cause death. Bleeding of nose and gums, ulceration of the nasal and oral mucosa, pulmonary edema, chronic bronchitis, and pneumonia may also occur. If the eyes have come in contact with dimethyldichlorosilane, irritation, pain, swelling, corneal erosion, and blindness may result. Dermatitis (red, inflamed skin), severe burns, pain, and shock generally follow dermal exposure. Inhalation irritates mucous membranes. Severe gastrointestinal damage may occur. Vapors cause severe eye and lung injury. Upon short contact, second and third degree burns may occur. Signs and symptoms of acute ingestion of dimethyldichlorosilane may be severe and include increased salivation, intense thirst, difficulty swallowing, chills, pain, and shock. Oral, esophageal, and stomach burns are common. /Dimethyldichlorosilane/|/SIGNS AND SYMPTOMS/ Inhalation irritates mucous membranes. Contact with liq causes severe burns of eyes and skin ... Vapors cause severe irritation of eyes and throat and can cause eye and lung injury. They cannot be tolerated even at low concn. Causes second- and third-degree burns on short contact ...|/SIGNS AND SYMPTOMS/ Causes severe eye and skin burns. Serious health hazard. May be harmful if inhaled. Irritating to eye, skin, and respiratory system. /Dimethylchlorosilane/|/SIGNS AND SYMPTOMS/ Causes severe eye and skin burns.|For more Human Toxicity Excerpts (Complete) data for Trichloropropylsilane (9 total), please visit the HSDB record page.

Propyltrichlorosilane Use and Manufacturing

Methods of Manufacturing

By Grignard reaction of silicon tetrachloride and propylmagnesium chloride.

Uses

Intermediate for silicones.


Fillers

Production

1,000,000 - 10,000,000 lb|Production volumes for non-confidential chemicals reported under the Inventory Update Rule. [Table#2352]|Production volume for non-confidential chemicals reported under the 2006 Inventory Update Rule. Chemical: Silane, trichloropropyl-. Aggreated National Production Volume: <500,000 lbs.

Grade: Technical

All other basic inorganic chemical manufacturing|Silane, trichloropropyl-: ACTIVE

Fire Hazards -> Corrosives, Flammable - 3rd degree, Reactive - 1st degree

Computed Properties

Molecular Weight:177.53
Rotatable Bond Count:1
Exact Mass:175.938260
Monoisotopic Mass:175.938260
Heavy Atom Count:7
Complexity:48.6
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of Propyltrichlorosilane

Latest News on Propyltrichlorosilane

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.