SECTION 1: Identification

1.1 GHS Product identifier

Product name

Methylpyridine

1.2 Other means of identification

Product number

-

Other names

methyl-pyridin;picolines;METHYL PYRIDINE

1.3 Recommended use of the chemical and restrictions on use

Identified uses

Food additives -> Flavoring Agents

Uses advised against

no data available

1.4 Supplier's details

Company

Echemi.com

Address

Echemi.com

Telephone

Echemi.com

1.5 Emergency phone number

Emergency phone number

Echemi.com

Service hours

Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

SECTION 2: Hazard identification

2.1 Classification of the substance or mixture

no data available

2.2 GHS label elements, including precautionary statements

Pictogram(s) no data available
Signal word

no data available

Hazard statement(s)

no data available

Precautionary statement(s)
Prevention

no data available

Response

no data available

Storage

no data available

Disposal

no data available

2.3 Other hazards which do not result in classification

no data available

SECTION 3: Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
Methylpyridine Methylpyridine 1333-41-1 215-588-6 100%

SECTION 4: First-aid measures

4.1 Description of necessary first-aid measures

If inhaled

Fresh air, rest. Refer for medical attention.

Following skin contact

Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer for medical attention .

Following eye contact

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

Following ingestion

Rinse mouth. Do NOT induce vomiting. Refer for medical attention .

4.2 Most important symptoms/effects, acute and delayed

INHALATION, INGESTION OR SKIN ABSORPTION: Narcosis, headache, nausea, giddiness, vomiting. EYES: Severe irritation. SKIN: Causes burns. INGESTION: Irritation and gastric upset. (USCG, 1999)

4.3 Indication of immediate medical attention and special treatment needed, if necessary

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Aromatic hydrocarbons and related compounds

SECTION 5: Fire-fighting measures

5.1 Suitable extinguishing media

To fight fire, use carbon dioxide, dry chemical.

5.2 Specific hazards arising from the chemical

Special Hazards of Combustion Products: When heated to decompo- sition, emits toxic fumes of cyanide. Behavior in Fire: Heat may cause pressure buildup in closed containers. Use water to keep container cool. (USCG, 1999)

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

SECTION 6: Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.

6.2 Environmental precautions

Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations. Personal protection: chemical protection suit including self-contained breathing apparatus.

6.3 Methods and materials for containment and cleaning up

Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.

SECTION 7: Handling and storage

7.1 Precautions for safe handling

Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

7.2 Conditions for safe storage, including any incompatibilities

Fireproof. Separated from oxidants.

SECTION 8: Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

8.2 Appropriate engineering controls

Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).

Skin protection

Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.

Thermal hazards

no data available

SECTION 9: Physical and chemical properties and safety characteristics

Physical state

2-methylpyridine is a colorless liquid with a strong, unpleasant odor. Floats on water. Poisonous vapor is produced. (USCG, 1999)

Colour

Colorless liquid

Odour

Strong unpleasant odor

Melting point/freezing point

-94° F (NTP, 1992)

Boiling point or initial boiling point and boiling range

127.5ºC at 760 mmHg

Flammability

Flammable. Gives off irritating or toxic fumes (or gases) in a fire.

Lower and upper explosion limit/flammability limit

no data available

Flash point

26.1ºC

Auto-ignition temperature

1000° F (USCG, 1999)

Decomposition temperature

no data available

pH

/SRP/: Weak base

Kinematic viscosity

no data available

Solubility

greater than or equal to 100 mg/mL at 68° F (NTP, 1992)

Partition coefficient n-octanol/water

log Kow = 1.11

Vapour pressure

8 mm Hg at 68° F ; 40 mm Hg at 124.2° F; 100 mm Hg at 160.5° F (NTP, 1992)

Density and/or relative density

0.941 g/cm3

Relative vapour density

3.21 (NTP, 1992) (Relative to Air)

Particle characteristics

no data available

SECTION 10: Stability and reactivity

10.1 Reactivity

Decomposes on burning. This produces toxic fumes including nitrogen oxides. Reacts with oxidants. Attacks copper and its alloys.

10.2 Chemical stability

2-Methylpyridine is highly stable in aqueous solns .

10.3 Possibility of hazardous reactions

Moderate fire risk2-METHYLPYRIDINE is hygroscopic. This compound reacts with hydrogen peroxide, iron(II) sulfate, sulfuric acid, oxidizing agents, acids, and metals. (NTP, 1992)

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

Mixtures with hydrogen peroxide + iron(II)sulfate + sulfuric acid may ignite & then explode.

10.6 Hazardous decomposition products

When heated to decomp, emits toxic fumes of nitrogen oxides.

SECTION 11: Toxicological information

Acute toxicity

  • Oral: LD50 Rat oral 790 mg/kg
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

SECTION 12: Ecological information

12.1 Toxicity

  • Toxicity to fish: LC50; Species: Pimephales promelas (fathead minnow); Conditions: flow-through bioassay with measured concentrations, 25.6 deg C, dissolved oxygen 7.0 mg/L, hardness 46.0 mg/L CaCO3, alkalinity 309 mg/L CaCO3, and pH 7.88; Concentration: 897 mg/L for 96 hr (confidence limit not reliable)
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

AEROBIC: 2-Methylpyridine was reported as readily biodegradable in the MITI test(1). In an aerobic screening test using an enrichment culture obtained from soil as an inoculum, 100% degradation was obtained in 14 to 32 days(2). When this test was repeated under anaerobic conditions, degradation was much slower, requiring >97 days for complete biodegradation(2). Only 2.7% of the added 2-methylpyridine (initial concentration of 2 umoles/g) remained after 16 days following incubation in a silt loam soil(3). Complete biodegradation of 2-methylpyridine, initially added at 4 mg/L, was reported in aerobic groundwater incubated at 15 deg C for 4 days(4). In an aerobic column study where subsurface sediment was leached with contaminated groundwater, 65% of the initially applied 2-methylpyridine was removed after 5 weeks of operation(5). Complete biodegradation of 2-methylpyridine was observed in 24 days following incubation in a defined medium inoculated with soil(6). Contaminated groundwater, from the American Creosote Works Superfund site in Pensacola, FL, was incubated with 2-methylpyridine; 33, 33, 33, 66, and 100% degradation was reported after incubation for 1, 3, 5, 8, and 14 days, respectively(7). 2-Methylpyridine, present at 100 mg/L, reached 0.1% of its theoretical BOD in 4 weeks using an activated sludge inoculum at 30 mg/L in the Japanese MITI test(8).

12.3 Bioaccumulative potential

An estimated BCF of 3 was calculated for 2-methylpyridine(SRC), using a log Kow of 1.11(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC). Low bioconcentration was reported for tests using carp (Cyprinus carpio)(4); however, actual BCF values were not available(SRC).

12.4 Mobility in soil

The sorption behavior of 2-methylpyridine was studied in soil column tests using 5 Eurosoil reference soils having organic carbon content ranging from 0.33-1.85% and pH ranging from 5.2-8.6(1); measured Kd values ranging from 0.08 to 6.52(1) correspond to calculated Koc values of 4, 38, 70, 100 and 215(SRC); the lowest Koc value of 4 corresponds to Eurosoil 2 which had the highest pH value(8.6). The pKa of 2-methylpyridine is 5.96(2), indicating that this compound will exist partially in cation form in the environment and cations generally adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(3). In the Eurosoil column tests(1), lowest adsorption occurred when 2-methylpyridine was in non-ionized form(1). Sorption of 2-methylpyridine to soil is primarily controlled by cation exchange and surface complex formation(1,4). According to a classification scheme(5), the Koc values suggest that 2-methylpyridine is expected to have very high to moderate mobility in soil.

12.5 Other adverse effects

no data available

SECTION 13: Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

SECTION 14: Transport information

14.1 UN Number

ADR/RID: UN2313 (For reference only, please check.) IMDG: UN2313 (For reference only, please check.) IATA: UN2313 (For reference only, please check.)

14.2 UN Proper Shipping Name

ADR/RID: PICOLINES (For reference only, please check.) IMDG: PICOLINES (For reference only, please check.) IATA: PICOLINES (For reference only, please check.)

14.3 Transport hazard class(es)

ADR/RID: 3 (For reference only, please check.) IMDG: 3 (For reference only, please check.) IATA: 3 (For reference only, please check.)

14.4 Packing group, if applicable

ADR/RID: III (For reference only, please check.) IMDG: III (For reference only, please check.) IATA: III (For reference only, please check.)

14.5 Environmental hazards

ADR/RID: No IMDG: No IATA: No

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to IMO instruments

no data available

SECTION 15: Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
Methylpyridine Methylpyridine 1333-41-1 215-588-6
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Not Listed.
New Zealand Inventory of Chemicals (NZIoC) Not Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Not Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Not Listed.
Korea Existing Chemicals List (KECL) Not Listed.

SECTION 16: Other information

Information on revision

Creation Date July 15, 2019
Revision Date July 15, 2019

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.