Product
Supplier
Encyclopedia
Inquiry
Home > Biochemical Engineering > Saccharides > Lithium heparin for Sale > The leader in biochemical tests-lithium heparin
The leader in biochemical tests-lithium heparin buy - large image1
The leader in biochemical tests-lithium heparin buy - image1

The leader in biochemical tests-lithium heparin

2 Inquiries

Unit Price: Get Latest Price
CAS No.:

9045-22-1

Grade:

Reagent Grade

Port:

SHANGHAI

Packaging:

0.05kg/Bottle

Price valid (until):

2021-01-01

Company Type:
Manufactory
Location:
China
Payment Terms:
TT against copy of documents
Average Lead Time:
15 days
Qualification:
Main Products:

luminescent substrates,buffers,in vitro diagnostic reagents,Blood collection tube additives

  • Product Description

  • Seller Information

  • Inquiry History

  • Description

    Heparin is commonly used in clinical blood tests with sodium and lithium salts, and has unique application value. Heparin has low chelating power, has little effect on the movement of water molecules, has little interference with blood components, does not affect the volume of red blood cells, and does not cause hemolysis, so In many tests that use whole blood or plasma as a specimen, heparin is recommended as an anticoagulant.

    Lithium heparin and sodium heparin both have anticoagulant effects in clinical practice, mainly used for thromboembolic diseases, myocardial infarction, cardiovascular surgery, cardiac catheterization, extracorporeal circulation, hemodialysis, etc. Because the combined ions are different, so Its dissociation degree is different, and the effect of lithium heparin is better than that of heparin sodium. 

    In the detection of pH, blood gas, electrolytes and calcium ions, heparin is the only anticoagulant that can be used, and lithium heparin has the least possibility of interference when detecting non-lithium ions, so it is recommended to use heparin lithium as an anticoagulant At present, in blood tests, lithium heparin is gradually replacing heparin sodium.

    For biochemical examination of patients after hemodialysis

    The blood sample of a patient after hemodialysis is a special sample faced by many hospital laboratory departments, and many inspectors often feel helpless when facing such samples. This is because dialysis patients use heparin-containing anticoagulant drugs such as low molecular weight heparin calcium during hemodialysis. At this time, because the blood contains a certain amount of heparin anticoagulant drugs, the blood is placed in a common tube or separation gel after the blood is drawn /The coagulant tube is extremely difficult to coagulate, and it is difficult to separate the serum.

    It has been reported that lithium heparin anticoagulated plasma and serum are used to test blood K. The analysis of the test results is biased. It may be that the blood sample rotates too high during the centrifugation process, and the red blood cells in the blood clot covered by the fibrin mesh are squeezed and destroyed. The release of K ions into the serum. In addition, a small amount of red blood cells will inevitably be destroyed during the transportation and coagulation of the blood sample, resulting in a slightly high blood K.

    It is also reported that there are significant differences between the results of CK-MB, LDH, GLU, etc., between the use of lithium heparin anticoagulated plasma and serum, which may be caused by the hemolysis of the specimen or the decomposition of blood sugar for too long. On the contrary, heparin anticoagulant has the advantages of not affecting cell volume and not easily causing hemolysis. It does not need to be placed in a water bath and can be centrifuged directly. The blood K, GLU, LDH, etc. measured with lithium heparin anticoagulated plasma are more accurate to the true concentration in the patient's body. Therefore, the establishment of a plasma biochemical test reference value system as soon as possible will help clinicians make accurate judgments on the patient's condition.

    For routine biochemical testing

    Research results show that most routine biochemical test items can use lithium heparin anticoagulated plasma instead of serum, but plasma reference ranges should be established for Glu, K+, Na+, CI-, P3-, and serum reference ranges can be used for other items to interpret plasma test results; Lp( a), PA, HBDH, LDH, CK, CKMB, IgM and other items should not be measured with lithium heparin anticoagulated plasma samples. Plasma Lp(a) increases with the increase of heparin concentration.

    Desheng has been in the R&D and production of blood collection tube additives for 15 years. It can be said to be an old-brand manufacturer of blood collection tube additives. Heparin sodium and lithium heparin are our main products. They are non-injectable grades and are mainly used for collection. The anticoagulant in vascular additives, that is, in vitro anticoagulant, is recommended by many companies for purchase. And we can also customize heparin products with a potency of 150IU-180IU according to customer needs.

    ECHEMI Editorial Reference
    Heparin Lithium salt is an anticoagulant which binds reversibly to antithrombin III (ATIII).

    Basic Info
    Product Name:

    Lithium heparin

    Other Name:

    Heparin,lithium salt;Lithium acid heparin;Lithium heparin;Lithium heparinate

    CAS No.:

    9045-22-1

    InChIKeys:

    HXSDFQWQRCUQHF-UHFFFAOYSA-N

    Molecular Weight:

    623.5

    Exact Mass:

    148.052429

    EC Number:

    232-681-7

    HScode:

    29319090

    Categories:

    Saccharides

    Characteristics
    PSA:

    343

    XLogP3:

    2.41

    Density:

    1.2±0.1 g/cm3

    Boiling Point:

    265.0±0.0 °C at 760 mmHg

    Flash Point:

    189.5±9.6 °C

    Refractive Index:

    1.616

    Storage Conditions:

    +15C to +30C

    Hazard Identification

    Classification of the substance or mixture

    Skin sensitization, Category 1

    Respiratory sensitization, Category 1

    GHS label elements, including precautionary statements

    Pictogram(s)
    Signal word

    Danger

    Hazard statement(s)

    H317 May cause an allergic skin reaction

    H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled

    Precautionary statement(s)
    Prevention

    P261 Avoid breathing dust/fume/gas/mist/vapours/spray.

    P272 Contaminated work clothing should not be allowed out of the workplace.

    P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...

    P284 [In case of inadequate ventilation] wear respiratory protection.

    Response

    P302+P352 IF ON SKIN: Wash with plenty of water/...

    P333+P317 If skin irritation or rash occurs: Get medical help.

    P321 Specific treatment (see ... on this label).

    P362+P364 Take off contaminated clothing and wash it before reuse.

    P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.

    P342+P316 If experiencing respiratory symptoms: Get emergency medical help immediately.

    Storage

    none

    Disposal

    P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.

    Other hazards which do not result in classification

    no data available

    Handling and Storage

    Precautions for safe handling

    Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

    Conditions for safe storage, including any incompatibilities

    Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.

  • Seller Information
    Business Type:

    Manufactory

    Main Products:

    luminescent substrates,buffers,in vitro diagnostic reagents,Blood collection tube additives

    Location:

    C8-2-2, Optical Valley United Technology City, Gedian Development Zone, Ezhou City. Hubei,China.

    Payment Terms:

    TT against copy of documents

    Average lead Time:

    15 days

    Total Annual Revenue:

    $5 million-$10 million

    Total Employees:

    11-50

    Year of Establishment:

    2017

    Desheng Biochemical specializes in the research, development, production and sales of blood collection tube additives, in vitro diagnostic reagents, buffers, and luminescent substrates. In terms of blood collection tube additives, it has formed its own intellectual property rights and professional production research and development capabilities. Provide products and raw material solutions for more than 100 domestic and foreign manufacturers.

    At present, our company mainly includes: blood sample anticoagulant series products, including heparin sodium, lithium heparin, trisodium citrate, dipotassium EDTA, tripotassium EDTA, potassium oxalate, etc .; blood sample procoagulant series products, including blood procoagulant powder, Blood procoagulants, etc .; materials used for pretreatment of blood specimens, including separation gels, silicifying agents, etc .; raw materials for diagnostic reagents include: buffers, chromogen substrate production and research and development, currently chromogen substrates (new Trinder's reagents) have TOOS , TOPS, ADOS, ADPS, ALPS, DAOS, HDAOS, MADB, MAOS, TODB, etc. Buffers include Tris, Bicine, Caps, Mops, Taps, EPPS, etc .; Buffer product, white crystal, purity> 99%, absorbance <0.05. TOOS, MAOS, TOPS and other products have white crystals, high purity (greater than 99%), and good solubility, which is different from light blue or brown products on the market.

    Desheng Technology's product quality and technology have been widely recognized and used by customers in the Chinese local market. Over the years, many well-known domestic blood tube manufacturers have chosen and used Desheng products. Our products have already gone to the world, serving the health and medical undertakings of people from all over the world, and we at Desheng are extremely proud and gratified.

  • Inquiry History
    2 Inquiries
    Country Product Purchase Quantity Date Posted
    Pakistan

    lithium heparin

    100 G Aug 24, 2026
    Pakistan

    Lithium heparin

    2 KG Sep 24, 2026
    Post an enquiry for this product
pic ×

Scan the QR Code to Share

All products displayed on this website are only for non-medical purposes such as industrial applications or scientific research, and cannot be used for clinical diagnosis or treatment of humans or animals. They are not medicinal or edible.

According to relevant laws and regulations and the regulations of this website, units or individuals who purchase hazardous materials should obtain valid qualifications and qualification conditions.

The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legitimacy of the content are the responsibility of the publishing company. ECHEMI does not bear any guarantee responsibility for this. Please be aware that risks in internet transactions objectively exist.

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.