Product
Supplier
Encyclopedia
Inquiry
Home > Biochemical Engineering > Polypeptide > ANGIOTENSINII,HUMAN for Sale > ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure
ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure buy - large image1
ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure buy - image1
ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure buy - image2
ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure buy - image3
ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure buy - image4
ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure buy - image5
ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure buy - image6

ANGIOTENSIN II, HUMAN CAS 4474-91-3 Raise blood pressure

Unit Price: Get Latest Price
CAS No.:

4474-91-3

Grade:

Pharmaceutical Grade

Content:

99%

Port:

tianjin

Brand:

Junjia

Packaging:

a vials of 5/10 mg ,a box of 10 vials

Price valid (until):

2024-02-10

Company Type:
Trader
Location:
China
Payment Terms:
TT against copy of documents,D/P,L/C,D/A,O/A,TT against B/L draft before shipment,100% TT in advance
Average Lead Time:
3 days
Qualification:
Main Products:

Blue copper peptide powder

  • Product Description

  • Seller Information

  • Description


      ANGIOTENSIN II, HUMAN  Detail  


    Blood pressure raiser. For low blood pressure due to traumatic or post-operative shock and general or lumbar anesthesia.


    product name: ANGIOTENSIN II, HUMAN
    CAS:4474-91-3
    MF:C50H71N13O12
    MW:1046.2
    EINECS:2017-001-1
    Density:1.1257 (rough estimate)
    BP:809.08°C (rough estimate)
    pka:pK1: 10.37 (25°C)
    Synonyms:


    DRVYIHPF;[ILE5]-ANGIOTENSIN2;HYPERTENSIONIIHUMAN;L-ASP-ARG-VAL-TYR-ILE-HIS-PRO-PHE;H-ASP-ARG-VAL-TYR-ILE-HIS-PRO-PHE-OH;ChemicalbookFLUORESCEIN-NHCS-NH-ASP-ARG-VAL-TYR-ILE-HIS-PRO-PHE-OH;ASP-ARG-VAL-TYR-ILE-HIS-PRO-PHE-OH2CH3CHOOHH2O;ANGIOTENSINII,HUMAN



    Adverse reactions and contraindications:


    sometimes can cause dizziness, headache, occasionally angina pectoris. Excess may cause bradycardia. Hypotension caused by excessive blood loss should replenish blood volume. Use with caution in patients with cardiac dysfunction.






      Delivery & packaging  



    Delivery time : 5-7days  (  except Chinese holiday ) ,within 12 hours after payment.

    package detail:Pack in boxes, 10 vials per box, optional 2 mg /5 mg /10 mg per vial.



      Company Profile  



    Shanghai Junjia with a brand new business model, has been providing quality services and preferential prices for every buyer. Customer demand-oriented, to improve customer production efficiency and quality as the goal, to network as a service platform, to provide the fastest quotation system and complete information market, the most honest transaction.
    We sincerely welcome customers at home and abroad to come and call us to negotiate business and seek common prosperity on the basis of equality and mutual benefit.




     FAQ  



    Q1: How can I place an order?
      A: You can place an order by contacting us directly through our website, email, or phone. Our customer service team will be happy to assist you.


    Q2: How long will it take to receive my order?
      A: Delivery times may vary depending on the shipping method you choose and your location. We will provide you with a delivery estimate when you place your order.


    Q3:How do you to handle quality complaints and the goods got loss?
      A: we will ship another same products for free to you or refund the money for your loss if there is a quality problem caused by us or the goods got loss because of force majeure in transportation.


    Q4:What's your advantage?
      A: Professional R&D team;Strictly quality control;Most competitive price;Fast delivery;24 hours service.

    ECHEMI Editorial Reference
    Angiotensin II human is a vasoconstrictor that acts on the AT1 and the AT2 receptor.
    Solid
    Ile(5)-angiotensin II is an angiotensin II that acts on the central nervous system (PDB entry: 1N9V). It has a role as a human metabolite. It is a tautomer of an Ile(5)-angiotensin II dizwitterion.|Angiotensin II is under investigation for the treatment of Sepsis, Septic Shock, Diabetes Mellitus, and Acute Renal Failure. Angiotensin II has been investigated for the treatment, basic science, and diagnostic of Hypertension, Renin Angiotensin System, and Idiopathic Membranous Nephropathy. As of December 21, 2017 the FDA approved La Jolla Pharmaceutical's Giapreza (angiotensin II) Injection for Intravenouse Infusion for the indication of acting as a vasoconstrictor to increase blood pressure in adults with septic or other distributive shock. The novelty of the medication lies in the fact that it is the first and only use of synthetic human angiotensin II to help maintain body blood pressure. Shock is the inability to maintain blood flow to vital tissues and the potential resultant organ failure and death within hours, no matter young or o ld. As distributive shock is the most common type of shock in the inpatient setting and affects up to one third of patients in the intensive care unit, the FDA determined that there is a need for treatment options for critically ill hypotensive patients who do not adequately respond to currently available therapies.|Angiotensin ii is a Vasoconstrictor. The physiologic effect of angiotensin ii is by means of Vasoconstriction.|Therapeutic Angiotensin II is a synthetic form of the endogenous angiotensin II, a peptide hormone of the renin-angiotensin-aldosterone system (RAAS) that causes vasoconstriction and an increase in blood pressure, that may be used for the treatment of septic or other distributive shock. Upon administration, therapeutic angiotensin II binds to angiotensin II type 1 receptor on vascular smooth muscle cells which leads to Ca2+/calmodulin-dependent phosphorylation of myosin. This causes smooth muscle contraction and results in vasoconstriction and an increase in blood pressure. Therapeutic angiotensin II also increases blood pressure by stimulating the release of the steroid hormone aldosterone, which regulates the renal absorption of water and sodium.|An octapeptide that is a potent but labile vasoconstrictor. It is produced from angiotensin I after the removal of two amino acids at the C-terminal by ANGIOTENSIN CONVERTING ENZYME. The amino acid in position 5 varies in different species. To block VASOCONSTRICTION and HYPERTENSION effect of angiotensin II, patients are often treated with ACE INHIBITORS or with ANGIOTENSIN II TYPE 1 RECEPTOR BLOCKERS.

    Basic Info
    Product Name:

    ANGIOTENSINII,HUMAN

    Other Name:

    AngII;DRVYIHPF;TY-10721;ANGIOTENSIN-2;ANGIOTENSINII;ANTI-ANGIOTENSINII;ile(5)-angiotensini;[ILE5]-ANGIOTENSIN2;angiotensinii(mouse);[Ile5]angiotensinII

    CAS No.:

    4474-91-3

    Molecular Formula:

    C50H71N13O12

    InChIKeys:

    CZGUSIXMZVURDU-JZXHSEFVSA-N

    Molecular Weight:

    1046.18

    Exact Mass:

    1045.534546

    EC Number:

    2017-001-1

    UNII:

    M089EFU921

    DSSTox ID:

    DTXSID4036778|DTXSID30196288

    NCI Thesaurus Code:

    C173802

    ATC Code:

    C09|C - Cardiovascular system

    Categories:

    Polypeptide

    Characteristics
    PSA:

    406.34000

    XLogP3:

    2.34

    Appearance:

    orange Powder

    Density:

    1.4±0.1 g/cm3

    Boiling Point:

    809.08°C (rough estimate)

    Refractive Index:

    1.664

    Water Solubility:

    soluble in water (25 mg/ml), and 5% Acetic Acid (1 mg/ml).

    Storage Conditions:

    −20°C

    Collision Cross Section:

    353.79 Ų [M+2H]2+ [CCS Type: DT, Method: stepped-field]|436.24 Ų [M+3H]3+ [CCS Type: DT, Method: stepped-field]|314.38 Ų [M+H]+ [CCS Type: DT, Method: stepped-field]

    Hazard Identification

    Classification of the substance or mixture

    no data available

    GHS label elements, including precautionary statements

    Pictogram(s) no data available
    Signal word

    no data available

    Hazard statement(s)

    no data available

    Precautionary statement(s)
    Prevention

    no data available

    Response

    no data available

    Storage

    no data available

    Disposal

    no data available

    Other hazards which do not result in classification

    no data available

    Handling and Storage

    Precautions for safe handling

    Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

    Conditions for safe storage, including any incompatibilities

    Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.

  • Seller Information
    Business Type:

    Trader

    Main Products:

    Blue copper peptide powder

    Location:

    Shanghai

    Payment Terms:

    TT against copy of documents,D/P,L/C,D/A,O/A,TT against B/L draft before shipment,100% TT in advance

    Average lead Time:

    3 days

    Total Annual Revenue:

    Less than $1 million

    Total Employees:

    11-50

    Year of Establishment:

    2023

  • Country Product Purchase Quantity Date Posted
    Post an enquiry for this product
pic ×

Scan the QR Code to Share

All products displayed on this website are only for non-medical purposes such as industrial applications or scientific research, and cannot be used for clinical diagnosis or treatment of humans or animals. They are not medicinal or edible.

According to relevant laws and regulations and the regulations of this website, units or individuals who purchase hazardous materials should obtain valid qualifications and qualification conditions.

The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legitimacy of the content are the responsibility of the publishing company. ECHEMI does not bear any guarantee responsibility for this. Please be aware that risks in internet transactions objectively exist.

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.