Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > Phosphorodichloridic acid, phenyl ester

Phosphorodichloridic acid, phenyl ester

Phosphorodichloridic acid, phenyl ester structure

Phosphorodichloridic acid, phenyl ester 

structure
  • CAS No:

    770-12-7

  • Formula:

    C6H5Cl2O2P

  • Chemical Name:

    Phosphorodichloridic acid, phenyl ester

  • Synonyms:

    Phosphorodichloridic acid,phenyl ester;Phenyl phosphorodichloridate;Phenylphosphoric dichloride;Phenoxydichlorophosphine oxide;Phenyl dichlorophosphate;Dichlorophenoxyphosphine oxide;Phenoxyphosphoryl dichloride;Phenyl dichlorophosphinate;NSC 44412

  • Categories:

    Organic Chemistry  >  Carboxylic Acids and Derivatives

Description

clear colourless to very slightly brown liquid


Monophenyl dichlorophosphate appears as a liquid. May severely irritate skin, eyes and mucous membranes.


Monophenyl dichlorophosphate appears as a liquid. May severely irritate skin, eyes and mucous membranes.

Phosphorodichloridic acid, phenyl ester Basic Attributes

210.98200

210.98

212-220-6

AE85WW9S5Z

44412

3265

DTXSID6044987

2942000000

Characteristics

36.11000

3.65110

Monophenyl dichlorophosphate appears as a liquid. May severely irritate skin, eyes and mucous membranes.

1.4145 g/cm3 @ Temp: 20 °C

-1ºC

242 °C

>230 °F

1.521-1.523

Decomposes in water

2-8ºC

0.05 mmHg

About the same density as water and moderately soluble in water.

Esters, Sulfate Esters, Phosphate Esters, Thiophosphate Esters, and Borate Esters

An hologenated organophosphate. Organophosphates are susceptible to formation of highly toxic and flammable phosphine gas in the presence of strong reducing agents such as hydrides. Partial oxidation by oxidizing agents may result in the release of toxic phosphorus oxides.

Safety Information

II

8

UN 1760

3

R34

S26-S36/37/39-S45

TD4393000

C

Stable under normal temperatures and pressures. May decompose on exposure to moist air or water.

P280-P305 + P351 + P338-P310

H314

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: Combustible material: may burn but does not ignite readily. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. Runoff may pollute waterways. Substance may be transported in a molten form. (ERG, 2016)

|Danger|H272 (14.04%): May intensify fire; oxidizer [Danger Oxidizing liquids; Oxidizing solids]|P210, P220, P221, P260, P264, P270, P273, P280, P301+P312, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P330, P363, P370+P378, P391, P405, and P501|Aggregated GHS information provided by 57 companies from 6 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: SMALL FIRE: Dry chemical, CO2 or water spray. LARGE FIRE: Dry chemical, CO2, alcohol-resistant foam or water spray. Move containers from fire area if you can do it without risk. Dike fire-control water for later disposal; do not scatter the material. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2016)

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2016)

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)

Drug Information

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: TOXIC; inhalation, ingestion or skin contact with material may cause severe injury or death. Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)

phenyl dichlorophosphate

Phosphorodichloridic acid, phenyl ester Use and Manufacturing

Uses

It is used for the synthesis of avermectin benzoate and the preparation of phosphodiester. It is also used as a coupling agent for the polymerization of sulfinic acid with ethanol, ammonia, triol, etc.

Phosphorodichloridic acid, phenyl ester: ACTIVE

Computed Properties

Molecular Weight:210.98
XLogP3:2.8
Hydrogen Bond Acceptor Count:2
Rotatable Bond Count:2
Exact Mass:209.9404218
Monoisotopic Mass:209.9404218
Topological Polar Surface Area:26.3
Heavy Atom Count:11
Complexity:162
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of Phosphorodichloridic acid, phenyl ester

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.