Product
Supplier
Encyclopedia
Inquiry
Home > Food Additives > Nutrition Supplements > cAMP for Sale > Adenosine Cyclophosphate
Adenosine Cyclophosphate buy - large image1
Adenosine Cyclophosphate buy - image1
Adenosine Cyclophosphate buy - image2
Adenosine Cyclophosphate buy - image3
Adenosine Cyclophosphate buy - image4
Adenosine Cyclophosphate buy - image5
Adenosine Cyclophosphate buy - image6

Adenosine Cyclophosphate

Unit Price: Get Latest Price
CAS No.:

60-92-4

Grade:

Food Grade

Content:

98%

Port:

xian

Brand:

Bolite

Packaging:

1kg/bag, 5kg/bag, 25kg/carton

Price valid (until):

2025-05-10

Company Type:
Trader
Location:
China
Qualification:
Main Products:

L-Ergothioneine,arbutin,glutathione

  • Product Description

  • Seller Information

  • Description


      Product Detail  


    Adenosine Cyclophosphate (Cyclic AMP/cAMP) Product Introduction


    1. Basic Information

    • Chemical Name: Adenosine-3’,5’-cyclic Monophosphate (Cyclic AMP)

    • CAS Number: 60-92-4 (common form) [^general^]

    • Molecular Formula: C₁₀H₁₂N₅O₆P

    • Appearance: White to off-white crystalline powder

    • Source: Synthesized via enzymatic or chemical methods; naturally occurs in cells as a secondary messenger .


    2. Technical Data

    Property Value
    Molecular Weight 329.21 g/mol
    Solubility Soluble in water, DMSO, and dilute acids .
    Stability Stable under dry, cool conditions; sensitive to enzymatic degradation (e.g., phosphodiesterases) .
    Storage Store at -20°C for long-term preservation .

    3. Key Functions

    • Secondary Messenger: Mediates intracellular signaling by activating protein kinase A (PKA), regulating metabolic processes (e.g., glycogen breakdown, lipolysis) [^general^].

    • Gene Expression Regulation: Modulates transcription factors like CREB (cAMP Response Element-Binding Protein) .

    • Cardiac Function: Influences heart contractility and rhythm via calcium channel regulation .

    • Neurotransmission: Enhances synaptic plasticity and memory formation in the central nervous system .


    4. Applications

    Research & Pharmaceuticals

    • Biochemical Studies: Used to study signal transduction pathways and enzyme kinetics [^general^].

    • Drug Development: Target for therapies addressing metabolic disorders (e.g., diabetes) and cardiovascular diseases .

    • Diagnostics: Marker for cellular stress or hormonal activity (e.g., adrenal function tests) .

    Industrial & Biotechnology

    • Cell Culture: Added to media to modulate cellular responses in bioproduction .

    Basic Info
    Product Name:

    cAMP

    Other Name:

    Adenosine,cyclic 3′,5′-(hydrogen phosphate);Adenosine 3′,5′-cyclic phosphate;4H-Furo[3,2-d]-1,3,2-dioxaphosphorin,adenosine deriv.;3′,5′-AMP;Adenosine cyclic 3′,5′-monophosphate;Adenosine 3′,5′-cyclophosphate;Adenosine 3′,5′-monophosphate;Adenosine 3′,5′-phosphate;Cyclic adenosine 3′,5′-phosphate;Cyclic 3′,5′-adenylic acid;Cyclic 3′,5′-monophosphate adenosine;Cyclic-3′,5′-phosphate adenosine;Cyclic AMP;Cyclic adenosine 3′,5′-monophosphate;Cyclic 3′,5′-AMP;cAMP;Adenosine cyclic monophosphate;NSC 143670;NSC 94017;AMPc;NQZ-026;11002-78-1

    CAS No.:

    60-92-4

    Molecular Formula:

    C10H12N5O6P

    InChIKeys:

    InChIKey=IVOMOUWHDPKRLL-KQYNXXCUSA-N

    Molecular Weight:

    329.21

    Exact Mass:

    329.21

    EC Number:

    200-492-9

    UNII:

    E0399OZS9N

    DSSTox ID:

    DTXSID8040436

    NCI Thesaurus Code:

    C208

    HScode:

    29349990

    Categories:

    Nutrition Supplements

    Characteristics
    PSA:

    155

    XLogP3:

    -2.96

    Appearance:

    white powder

    Density:

    2.5±0.1 g/cm3

    Melting Point:

    219-220 °C

    Boiling Point:

    701.5°C at 760 mmHg

    Flash Point:

    378.0±35.7 °C

    Refractive Index:

    2.012

    Water Solubility:

    H2O: 10 mg/mL pH of aqueous solution is approx. 3.0. The sodium salt (A6885) is about 20× more soluble ., clear, colorless

    Storage Conditions:

    2-8°C

    Toxicity:

    oms-hmn:oth 100 mmol/L JIDEAE 65,52,75

    Flammability characteristics:

    Flammable; heat produces toxic nitrogen oxides and phosphorus oxide fumes

    Specific rotation:

    -53.7 º (c=0.7,water)

    Collision Cross Section:

    176.8 Ų [M+H]+ [CCS Type: DT, Method: single field calibrated with Agilent tune mix (Agilent)]|175.07 Ų [M-H]- [CCS Type: DT, Method: stepped-field]|172 Ų [M+H]+ [CCS Type: TW, Method: calibrated with polyalanine]|172.6 Ų [M+H]+ [CCS Type: DT, Method: single field calibrated with ESI Low Concentration Tuning Mix (Agilent)]|176.8 Ų [M+H]+ [CCS Type: DT, Method: single field calibrated with ESI Low Concentration Tuning Mix (Agilent)]|181 Ų [M+Na]+ [CCS Type: DT, Method: single field calibrated with ESI Low Concentration Tuning Mix (Agilent)]|188.6 Ų [M+Na]+ [CCS Type: DT, Method: single field calibrated with ESI Low Concentration Tuning Mix (Agilent)]|188.8 Ų [M+Na]+ [CCS Type: DT, Method: single field calibrated with ESI Low Concentration Tuning Mix (Agilent)]|171.8 Ų [M-H]- [CCS Type: DT, Method: single field calibrated with ESI Low Concentration Tuning Mix (Agilent)]|172 Ų [M-H]- [CCS Type: DT, Method: single field calibrated with ESI Low Concentration Tuning Mix (Agilent)]|171.9 Ų [M-H]-

    Hazard Identification

    Classification of the substance or mixture

    Skin irritation, Category 2

    Eye irritation, Category 2

    GHS label elements, including precautionary statements

    Pictogram(s)
    Signal word

    Warning

    Hazard statement(s)

    H315 Causes skin irritation

    H319 Causes serious eye irritation

    H335 May cause respiratory irritation

    Precautionary statement(s)
    Prevention

    P264 Wash ... thoroughly after handling.

    P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...

    Response

    P302+P352 IF ON SKIN: Wash with plenty of water/...

    P321 Specific treatment (see ... on this label).

    P332+P317 If skin irritation occurs: Get medical help.

    P362+P364 Take off contaminated clothing and wash it before reuse.

    P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

    Storage

    none

    Disposal

    none

    Other hazards which do not result in classification

    no data available

    Handling and Storage

    Precautions for safe handling

    Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

    Conditions for safe storage, including any incompatibilities

    Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.

  • Seller Information
    Business Type:

    Trader

    Main Products:

    L-Ergothioneine,arbutin,glutathione

    Location:

    Room 12208, Floor 22, Unit 1, Building 1, Daming Palace Wanda Plaza, No. 369 North of Taihua Road, Weiyang District, Xi 'an City, Shaanxi Province, China Zip code:710016

    Payment Terms:

    TT against copy of documents,D/P,L/C,TT against B/L draft before shipment,100% TT in advance

    Average lead Time:

    15

    Total Annual Revenue:

    $1 million-$2.5 million

    Total Employees:

    11-50

    Year of Establishment:

    2020

    Xian Bolite Laboratory Technology Co.Ltd is a leading Trader supplier of PALMITOYL TETRAPEPTIDE-3, Syn-ake, L-Carnosine based in Xi'an, Shaanxi, China. With a commitment to quality and customer satisfaction, Xian Bolite Laboratory Technology Co.Ltd has become a trusted name in the industry. Our product line includes a range of high-quality PALMITOYL TETRAPEPTIDE-3, Syn-ake, L-Carnosine, which are available at competitive prices. Xian Bolite Laboratory Technology Co.Ltd has established itself as a reliable supplier of chemical products on the echemi.com.

  • Country Product Purchase Quantity Date Posted
    Post an enquiry for this product
pic ×

Scan the QR Code to Share

All products displayed on this website are only for non-medical purposes such as industrial applications or scientific research, and cannot be used for clinical diagnosis or treatment of humans or animals. They are not medicinal or edible.

According to relevant laws and regulations and the regulations of this website, units or individuals who purchase hazardous materials should obtain valid qualifications and qualification conditions.

The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legitimacy of the content are the responsibility of the publishing company. ECHEMI does not bear any guarantee responsibility for this. Please be aware that risks in internet transactions objectively exist.

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.