Product
Supplier
Encyclopedia
Inquiry
Home > Inorganic Chemistry > Industrial Gases > Hydrogen Sulfide for Sale > Hydrogen Sulfide Supplier H2S Gas
Hydrogen Sulfide Supplier H2S Gas buy - large image1
Hydrogen Sulfide Supplier H2S Gas buy - image1
Hydrogen Sulfide Supplier H2S Gas buy - image2
Hydrogen Sulfide Supplier H2S Gas buy - image3
Hydrogen Sulfide Supplier H2S Gas buy - image4
Hydrogen Sulfide Supplier H2S Gas buy - image5

Hydrogen Sulfide Supplier H2S Gas

3 Inquiries

Unit Price: Get Latest Price
CAS No.:

7783-06-4

Grade:

Industrial Grade

Content:

99.9%

Port:

ShangHai

Brand:

Chengdu xenon

Packaging:

47L/30 kgs

Price valid (until):

2026-05-25

Company Type:
Trader
Location:
China
Qualification:
Main Products:

Industrial Gases

  • Product Description

  • Seller Information

  • Inquiry History

  • Description

    Hydrogen Sulfide For Sale

    Hydrogen sulfide, is a kind of inorganic compound, under standard conditions is a flammable acid gas, colorless, low concentration has rotten egg smell, very low concentration has sulfur smell, there is a highly toxic. The aqueous solution is hydrosulfuric acid, which is less acidic, weaker than carbonic acid but stronger than boric acid. Soluble in water, soluble in alcohol, petroleum solvents and crude oil.


    CAS NO  7783-06-4
    UN NO  1053
    EINECS NO  231-977-3
    Molecular weight  34.08
    Appearance  Colorless, Rotten egg smell
    Melting point  -85.5 ℃
    Boiling point  -60.4 ℃
    Density 1.36 kg/m³
    DOT Class  2.3 & 2.1
    Label  Toxic Gas, Flammable Gas


    Specification 98%
    Hydrogen ≤ 0.08%
    Carbon Dioxide ≤ 1.6%
    Nitrogen ≤ 0.08%
    Propane ≤ 0.02%
    Oxygen ≤ 0.02%
    Moisture ≤ 50 ppm
     
    Specification 99.5%
    Hydrogen ≤ 0.02%
    Carbon Dioxide ≤ 0.4%
    Nitrogen ≤ 0.01%
    Propane ≤ 0.01%
    Oxygen ≤ 0.02%
    Moisture ≤ 50 ppm

     

    Specification 99.9%
    Hydrogen ≤ 0.02%
    Carbon Dioxide ≤ 0.03%
    Nitrogen ≤ 0.03%
    Propane ≤ 0.01%
    Oxygen ≤ 0.01%
    Moisture ≤ 20 ppm

     

    Cylinder Capacity Valve Weight
    47L CGA350 30 kgs

    Basic Info
    Product Name:

    Hydrogen Sulfide

    Other Name:

    HYDROGEN SULFIDE, SOLID;HYDROGEN SULFIDE WATER;HYDROGEN SULFIDE WATER, SAT;HYDROGEN SULFIDE;Acide sulfhydrique;acidesulfhydrique;acidesulfhydrique(french);acidesulphhydrique

    CAS No.:

    7783-06-4

    Molecular Formula:

    H2S

    InChIKeys:

    RWSOTUBLDIXVET-UHFFFAOYSA-N

    Molecular Weight:

    34.08

    Exact Mass:

    33.988

    BRN:

    3535004

    EC Number:

    231-977-3

    TSCA:

    TSCA listed

    Color/Form:

    colorless gas; flammable

    HScode:

    2830909000

    Categories:

    Industrial Gases

    Characteristics
    PSA:

    1

    Physical Properties:

    H2S is soluble in carbon disulfide, methanol, acetone and alkanolamines. A solution of hydrogen sulfide in water is initially clear but over time turns cloudy. This is due to the slow reaction of hydrogen sulfide with the oxygen dissolved in water, yielding elemental sulfur, which precipitates out.

    XLogP3:

    0.5

    Appearance:

    Hydrogen sulfide appears as a colorless gas having a strong odor of rotten eggs. Boiling point -60.2°C. Shipped as a liquid confined under its own vapor pressure. Density (liquid) 8.3 lb / gal. Contact with the unconfined liquid can cause frostbite by evaporative cooling. Gas is very toxic by inhalation. Fatigues the sense of smell which cannot be counted on to warn of the continued presence of the gas. Prolonged exposure of closed containers to heat may result in their violent rupturing and rocketing. Rate of onset: Immediate & Delayed Persistence: Minutes to hours Odor threshold: 0.1 ppm Source/use/other hazard: Disinfectant lubricant/oils; interm for HC manufacture; deadens sense of smell.

    Density:

    dgas 1.19 (air = 1.00)

    Melting Point:

    −85 °C(lit.)

    Boiling Point:

    −60 °C(lit.)

    Flash Point:

    -17℃

    Water Solubility:

    1g dissolves in H2O: 187mL (10°C), 242mL (20°C), 314 (30°C) [MER06]

    Storage Conditions:

    2-8°C

    Vapor Pressure:

    252 psi ( 21 °C)

    Vapor Density:

    1.19 (15 °C, vs air)

    Toxicity:

    Toxicity of hydrogen sulfide is most likely related to inhibition of metal-containing enzymes such as cytochrome oxidase, the final enzyme of the mitochondrial respiratory chain, and carbonic anhydrase. Therefore, hydrogen sulfide affects cellular energy production and respiration. Mucous membranes and tissues with a high oxygen demand, like nervous and cardiac tissues are most susceptible tissues in exposure to hydrogen sulfide. In addition, sulfide also seems to act on the respiratory drive through other mechanisms such as suppression of synaptic activity, inhibition of monoamine oxidase, a direct action on respiratory centers in the brain, and stimulation of the glutamate receptors in the brain. The hydrosulfide anion also forms a complex with methemoglobin and creates sulfmethemoglobin. On the other hand, hydrosulfide can be produced endogenously, particularly in mammalian cells, through an enzymatic pathway and in a smaller part via a nonenzymatic pathway. Among enzymes involved in hydrosulfide production, cystathionine- synthase and cystathionine-lyase have been investigated extensively; both use vitamin B6 as a cofactor. Captopyruvate sulfurtransferase along with cysteine aminotransferase are involved in transsulfuration and reverse transsulfuration pathways in different capacities and utilize specific substrates. Of course, the regulation mechanisms for the expression and activities of these hydrosulfide-generating enzymes under physiological or pathophysiological conditions needs more research. These enzymes are differentially expressed in neuronal, immune, cardiovascular, renal, gastrointestinal, reproductive, respiratory, liver, and endocrine systems and affect the functions of these systems through production of hydrosulfide. Meanwhile, different molecular targets, such as different ion channels and signaling proteins, mediate physiological functions of hydrogen sulfide. Alternations of hydrosulfide metabolism lead to an array of pathological disturbances in the form of hypertension, diabetes, cirrhosis, atherosclerosis, heart failure, inflammation, sepsis, erectile dysfunction, asthma, and neurodegenerative disease.

    Flammability characteristics:

    Hydrogen sulfide is flammable in air in the range of 4.3 to 45.5% (NFPA rating = 4). Combustion products (sulfur oxides) are also toxic by inhalation. In the event of a hydrogen sulfide fire, stop the flow of gas if possible without risk of harmful exposure and let the fire burn itself out.

    Explosive limit:

    6%

    Odor:

    Strong rotten egg odor detectable at 0.001 to 0.1 ppm (mean = 0.0094 ppm); olfactory fatigue occurs quickly at high concentrations

    Taste:

    Sweetish taste

    PH:

    pKa1= 6.90, pKa2 = 13.48(25℃)

    PKA:

    7(at 25℃)

    Henrys Law Constant:

    1.0×10-3mol/(m3Pa) at 25℃, Burkholder et al. (2019)

    Air and Water Reactions:

    Highly flammable; a flame can very easily flash back to the source of leak. Soluble in water to a maximum of 0.4% by mass at room temperature .

    Reactivity Profile:

    HYDROGEN SULFIDE reacts as an acid and as a reducing agent. Explodes on contact with oxygen difluoride, bromine pentafluoride, chlorine trifluoride, dichlorine oxide, silver fulminate. May ignite and explode when exposed to powdered copper in oxygen [Mertz, V. et al., Ber., 1880, 13, p. 722]. May react similarly with other powdered metals. Ignites on contact with metal oxides and peroxides (barium peroxide, chromium trioxide, copper oxide, lead dioxide, manganese dioxide, nickel oxide, silver oxide, silver dioxide, thallium trioxide, sodium peroxide, mercury oxide, calcium oxide) [Mellor, 1947, vol. 10, p. 129, 141]. Ignites with silver bromate, lead(II) hypochlorite, copper chromate, nitric acid, lead(IV) oxide and rust. May ignite if passed through rusty iron pipes [Mee, A. J., School Sci. Rev., 1940, 22(85), p. 95]. Reacts exothermically with bases. The heat of the reaction with soda lime, sodium hydroxide, potassium hydroxide, barium hydroxide may lead to ignition or explosion of the unreacted portion in the presence of air / oxygen [Mellor, 1947, vol. 10, p. 140].

    Autoignition Temperature:

    260 °C

    Critical Temperature & Pressure:

    2-8°C

    Hazard Identification

    Classification of the substance or mixture

    Gases under pressure: Liquefied gas

    Flammable gases, Category 1A, Flammable gas

    Acute toxicity - Category 2, Inhalation

    Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1

    GHS label elements, including precautionary statements

    Pictogram(s)
    Signal word

    Danger

    Hazard statement(s)

    H220 Extremely flammable gas

    H330 Fatal if inhaled

    H400 Very toxic to aquatic life

    Precautionary statement(s)
    Prevention

    P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

    P260 Do not breathe dust/fume/gas/mist/vapours/spray.

    P271 Use only outdoors or in a well-ventilated area.

    P284 [In case of inadequate ventilation] wear respiratory protection.

    P273 Avoid release to the environment.

    Response

    P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.

    P381 In case of leakage, eliminate all ignition sources.

    P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.

    P316 Get emergency medical help immediately.

    P320 Specific treatment is urgent (see ... on this label).

    P391 Collect spillage.

    Storage

    P410+P403 Protect from sunlight. Store in a well-ventilated place.

    P403 Store in a well-ventilated place.

    P403+P233 Store in a well-ventilated place. Keep container tightly closed.

    Disposal

    P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.

    Other hazards which do not result in classification

    no data available

    Handling and Storage

    Precautions for safe handling

    NO open flames, NO sparks and NO smoking. Closed system, ventilation, explosion-proof electrical equipment and lighting. Prevent build-up of electrostatic charges (e.g., by grounding) if in liquid state. Do NOT use compressed air for filling, discharging, or handling. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

    Conditions for safe storage, including any incompatibilities

    Fireproof. Separated from strong oxidants. Cool. Keep in a well-ventilated room. Install continous monitoring system with alarm.Store in cool, dry, well-ventilated location. Separate from chlorates, nitrates, other oxidizing materials, and hydrocarbons.

  • Seller Information
    Business Type:

    Trader

    Main Products:

    Industrial Gases

    Location:

    No. 1015, Floor 10, Unit 1, Building 2, No. 1700, North Section of Tianfu Avenue, Chengdu High-tech Zone, China (Sichuan) Pilot Free Trade Zone

    Payment Terms:

    D/P,L/C,D/A

    Total Annual Revenue:

    $1 million-$2.5 million

    Total Employees:

    11-50

    Year of Establishment:

    2018

    Certifications:

    Occupational Health,Environmental management

    Your Trusted Partner for High-Purity & Specialty Gases

    Chengdu Xenon Tritium Technology Co., Ltd. is a professional supplier of specialty gases, high-purity gases, ultra-high purity gases, and rare gases. Founded in 2018 and headquartered in the Chengdu High-tech Zone, we have rapidly grown into a reliable partner for the semiconductor, power, medical, and research sectors.

    Our Core Competencies:

    Deep Industry Expertise: With over 15 years of collective experience in the gas industry and more than 5 years in international trade, our team possesses the technical knowledge to serve demanding applications.

    Comprehensive Product Portfolio: We offer a wide spectrum of products, including electronic specialty gases (Silane, Tungsten Hexafluoride, Nitrogen Trifluoride), rare gases (Xenon, Krypton, Neon), isotope gases (Deuterium), and standard gas mixtures. We also provide gas handling equipment such as valves, hoses, and filling fittings.

    Quality Assurance: We operate with a strict quality control system. Our high-purity gases (up to 6N grade) meet rigorous international standards, and every shipment is accompanied by a Certificate of Analysis (COA) and Material Safety Data Sheet (MSDS).

    Safety & Logistics: Safety is our priority. We employ a specialized logistics team for dangerous goods, utilize professional vehicles, and provide 24/7 monitoring to ensure safe and timely delivery. We offer a variety of packaging options from high-pressure steel cylinders to ISO tanks.

    Our Service Philosophy: We are not just a gas supplier; we are a one-stop solution provider. From custom gas mixture formulation (ppm to % levels) to the design of gas delivery systems (like BSGS for electronics), we support our clients with responsive service and technical guidance.

    Partner with Us: Whether you need a reliable source for critical semiconductor materials, standard gases for laboratory calibration, or rare gases for cutting-edge research, Chengdu Xenon Tritium Technology is your partner of choice. Contact us to discuss how we can support your success.

  • Inquiry History
    3 Inquiries
    Country Product Purchase Quantity Date Posted
    Spain

    Hydrogen Sulfide 99% gas 7783-06-4

    1000 KG Oct 9, 2023
    Spain

    Hydrogen Sulfide 99% gas 7783-06-4 Dideu

    200000000 KG Jun 15, 2025
    Spain

    hydrogen sulfide

    700 MT Jul 15, 2025
    Post an enquiry for this product
pic ×

Scan the QR Code to Share

All products displayed on this website are only for non-medical purposes such as industrial applications or scientific research, and cannot be used for clinical diagnosis or treatment of humans or animals. They are not medicinal or edible.

According to relevant laws and regulations and the regulations of this website, units or individuals who purchase hazardous materials should obtain valid qualifications and qualification conditions.

The information shown above is provided by the enterprise itself, and the authenticity, accuracy and legitimacy of the content are the responsibility of the publishing company. ECHEMI does not bear any guarantee responsibility for this. Please be aware that risks in internet transactions objectively exist.

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.