Product
Supplier
Encyclopedia
Inquiry
Home > Encyclopedia > 1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone

1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone

1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone structure

1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone 

structure
  • CAS No:

    813-44-5

  • Formula:

    C7F14O

  • Chemical Name:

    1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone

  • Synonyms:

    3-Pentanone,1,1,1,2,4,5,5,5-octafluoro-2,4-bis(trifluoromethyl)-;1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone;Perfluoroisopropyl ketone;Perfluorodiisopropyl ketone;Perfluorobis(isopropyl) ketone;Tetradecafluoro-2,4-dimethylpentan-3-one

  • Categories:

    Organic Chemistry  >  Coordination Complexes

Description

BIS(PERFLUORISOPROPYL) KETONE is a liquid.


Bis(perfluorisopropyl) ketone is a liquid.


Bis(perfluorisopropyl) ketone is a liquid.

1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone Basic Attributes

366.05

366.05

1916532

212-384-9

2810

DTXSID4074855

2914700090

Characteristics

17.1

4.22130

Bis(perfluorisopropyl) ketone is a liquid.

1.661

71-72 °C

72-73°C

1.267

No rapid reaction with air. No rapid reaction with water.

Ketones

Ketones, such as BIS(PERFLUORISOPROPYL) KETONE, are reactive with many acids and bases liberating heat and flammable gases (e.g., H2). The amount of heat may be sufficient to start a fire in the unreacted portion of the ketone. Ketones react with reducing agents such as hydrides, alkali metals, and nitrides to produce flammable gas (H2) and heat. Ketones are incompatible with isocyanates, aldehydes, cyanides, peroxides, and anhydrides. They react violently with aldehydes, HNO3, HNO3 + H2O2, and HClO4.

Safety Information

III

IRRITANT

2810

20/22-36/37/38

26-36/37/39

Xi

Irritant

Stability

P261, P264, P270, P271, P280, P301+P312, P302+P352, P304+P312, P304+P340, P305+P351+P338, P312, P321, P330, P332+P313, P337+P313, P362, P403+P233, P405, P501

H302

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: Combustible material: may burn but does not ignite readily. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. Runoff may pollute waterways. Substance may be transported in a molten form. (ERG, 2016)

|Warning|H302 (83.33%): Harmful if swallowed [Warning Acute toxicity, oral]|P261, P264, P270, P271, P280, P301+P312, P302+P352, P304+P312, P304+P340, P305+P351+P338, P312, P321, P330, P332+P313, P337+P313, P362, P403+P233, P405, and P501|Aggregated GHS information provided by 7 companies from 4 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

A fire in your laboratory involving this chemical should be extinguished with a dry chemical, carbon dioxide or halon extinguisher. (NTP, 1992)

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

SMALL SPILLS AND LEAKAGE: If you spill this chemical, use absorbent paper to pick up all liquid spill material. Your contaminated clothing and absorbent paper should be sealed in a vapor-tight plastic bag for eventual disposal. Solvent wash all contaminated surfaces with alcohol followed by washing with a strong soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned. STORAGE PRECAUTIONS: You should store this material in a refrigerator. (NTP, 1992)

RECOMMENDED RESPIRATOR: When working with this chemical, wear a NIOSH-approved full face chemical cartridge respirator equipped with the appropriate organic vapor cartridges. If that is not available, a half face respirator similarly equipped plus airtight goggles can be substituted. However, please note that half face respirators provide a substantially lower level of protection than do full face respirators. RECOMMENDED GLOVE MATERIALS: Permeation data indicate that butyl rubber gloves may provide protection to contact with this compound. Butyl rubber over latex gloves is recommended. However, if this chemical makes direct contact with your gloves, or if a tear, hole or puncture develops, remove them at once. (NTP, 1992)

Drug Information

Excerpt from ERG Guide 153 [Substances - Toxic and/or Corrosive (Combustible)]: TOXIC; inhalation, ingestion or skin contact with material may cause severe injury or death. Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Effects of contact or inhalation may be delayed. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)

EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop. SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. If symptoms such as redness or irritation develop, IMMEDIATELY call a physician and be prepared to transport the victim to a hospital for treatment. INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing. INGESTION: DO NOT INDUCE VOMITING. Volatile chemicals have a high risk of being aspirated into the victim's lungs during vomiting which increases the medical problems. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. IMMEDIATELY transport the victim to a hospital. (NTP, 1992)

1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone Use and Manufacturing

3-Pentanone, 1,1,1,2,4,5,5,5-octafluoro-2,4-bis(trifluoromethyl)-: ACTIVE|PMN - indicates a commenced PMN (Pre-Manufacture Notices) substance.

PFAS (per- and polyfluoroalkyl substances) -> OECD Category

Computed Properties

Molecular Weight:366.05
XLogP3:4.9
Hydrogen Bond Acceptor Count:15
Rotatable Bond Count:2
Exact Mass:365.9725589
Monoisotopic Mass:365.9725589
Topological Polar Surface Area:17.1
Heavy Atom Count:22
Complexity:364
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Recommended Suppliers of 1,1,1,2,4,5,5,5-Octafluoro-2,4-bis(trifluoromethyl)-3-pentanone

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.