Calcium permanganate

Calcium permanganate structure

Calcium permanganate 

structure
  • CAS No:

    10118-76-0

  • Formula:

    Ca.2HMnO4

  • Chemical Name:

    Calcium permanganate

  • Synonyms:

    Permanganic acid (HMnO4),calcium salt;Calcium permanganate (Ca(MnO4)2);Acerdol;Calcium permanganate;Calcium manganate [Ca(MnO4)2]

Description

violet or dark purple, deliquescent crystal(s); made by reacting KMnO4 and CaCl2; used in the textile industry, to sterilize water, and as a deodorizer [HAW93] [MER06]Purple crystalline solid. CALCIUM PERMANGANATE is used as a disinfectant and deodorizer, in water purification, and for many other uses.


Calcium permanganate is a purple crystalline solid. It is used as a disinfectant and deodorizer, in water purification, and for many other uses.


Calcium permanganate is a purple crystalline solid. It is used as a disinfectant and deodorizer, in water purification, and for many other uses.

Calcium permanganate Basic Attributes

277.95

277.79800

233-322-7

720Y4E8F5H

1456

Violet or dark-purple deliquescent crystals

Characteristics

149

Calcium permanganate is a purple crystalline solid. It is used as a disinfectant and deodorizer, in water purification, and for many other uses.

2.4 g/cm3

214 °C(lit.)

220 °F

n20/D 1.483(lit.)

Freely soluble in water

KEEP TIGHTLY CLOSED.

Intravenous-Rabbit LDL0: 50mg/kg

Combustion produces toxic fumes of manganese-containing compounds

Decomposes in alcohol|Strong oxidizer /tetrahydrate/|Decomposes 130-40 °C /Tetrahydrate/|PURPLE CRYSTALS; DENSITY: 2.4; 331 G SOL IN 100 CC WATER @ 14 °C; 338 G SOL IN 100 CC WATER @ 25 °C; SOL IN AMMONIUM HYDROXIDE /PENTAHYDRATE/

Water soluble.

Oxidizing Agents, Strong

Strong Oxidizing Agent

CALCIUM PERMANGANATE is an oxidizing agent. Noncombustible but it will accelerate the burning of combustible material. If the combustible material is finely divided the mixture may be explosive. Contact with liquid combustible materials may result in spontaneous ignition. Contact with sulfuric acid may cause fires or explosions. Mixtures with acetic acid or acetic anhydride can explode if not kept cold [Von Schwartz 1918 p. 34 ]. Explosions can occur when calcium permanganate that has been treated with sulfuric acid comes in contact with benzene, carbon disulfide, diethyl ether, ethyl alcohol, petroleum, or other organic matter.

Safety Information

II

5.1

1456

3

R36/37/38:Irritating to eyes, respiratory system and skin .

S26:In case of contact with eyes, rinse immediately with plenty of water and seek medical advice . S36:Wear suitable protective clothing .

Xi

The warehouse is ventilated, low temperature and dry; lightly loaded and unloaded; stored separately from organic matter, reducing agents, sulfur, phosphorus, hydrogen peroxide, and flammable materials

Mixed with reducing agent, sulfur, phosphorus, etc. can be explosive by heat, impact and friction; react with acetic acid, acetic anhydride and explode

SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.

Incompatibilities: Acetic acid or acetic anhydride; hydrogen peroxide|Calcium permanganate is a more active oxidant than the potassium salt and ignites paper or cotton on contact.|Dangerous fire risk in contact with organic materials. /Tetrahydrate/|COOLING IS NECESSARY TO PREVENT POSSIBLE EXPLOSION FROM CONTACT OF ... CALCIUM PERMANGANATE WITH ACETIC ACID OR ITS ANHYDRIDE.|For more Hazardous Reactivities and Incompatibilities (Complete) data for CALCIUM PERMANGANATE (7 total), please visit the HSDB record page.

Excerpt from ERG Guide 140 [Oxidizers]: These substances will accelerate burning when involved in a fire. Some may decompose explosively when heated or involved in a fire. May explode from heat or contamination. Some will react explosively with hydrocarbons (fuels). May ignite combustibles (wood, paper, oil, clothing, etc.). Containers may explode when heated. Runoff may create fire or explosion hazard. (ERG, 2016)

Excerpt from ERG Guide 140 [Oxidizers]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet). FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

Excerpt from ERG Guide 140 [Oxidizers]: Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Do not get water inside containers. SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area. SMALL LIQUID SPILL: Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal. LARGE SPILL: Dike far ahead of liquid spill for later disposal. Following product recovery, flush area with water. (ERG, 2016)

Excerpt from ERG Guide 140 [Oxidizers]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection. (ERG, 2016)|Personnel protection: ... Wear appropriate chemical protective gloves, boots and goggles.

If material on fire or involved in fire: Flood with water. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.|Evacuation: If fire becomes uncontrollable - consider evacuation of one-half (1/2) mile radius.

SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants.|WHEN USING WITH STRONG ACIDS TO DESTROY ORGANIC MATTER, PERFORM REACTION BEHIND SAFETY BARRIER. /PERMANGANATES/|If material not on fire and not involved in fire: Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers.|Personnel protection: Avoid breathing dusts. Avoid bodily contact with the material. ... Do not handle broken packages unless wearing appropriate personal protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. ...

/GUIDE 140: OXIDIZERS/ Fire or Explosion: These substances will accelerate burning when involved in a fire. Some may decompose explosively when heated or involved in a fire. May explode from heat or contamination. Some will react explosively with hydrocarbons (fuels). May ignite combustibles (wood, paper, oil, clothing, etc.). Containers may explode when heated. Runoff may create fire or explosion hazard.|/GUIDE 140: OXIDIZERS/ Health: Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause pollution.|/GUIDE 140: OXIDIZERS/ Public Safety: CALL Emergency Response Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover. As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate closed spaces before entering.|/GUIDE 140: OXIDIZERS/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection.|For more DOT Emergency Guidelines (Complete) data for CALCIUM PERMANGANATE (8 total), please visit the HSDB record page.

No person may /transport,/ offer or accept a hazardous material for transportation in commerce unless that person is registered in conformance ... and the hazardous material is properly classed, described, packaged, marked, labeled, and in condition for shipment as required or authorized by ... /the hazardous materials regulations (49 CFR 171-177)./|The International Air Transport Association (IATA) Dangerous Goods Regulations are published by the IATA Dangerous Goods Board pursuant to IATA Resolutions 618 and 619 and constitute a manual of industry carrier regulations to be followed by all IATA Member airlines when transporting hazardous materials.|The International Maritime Dangerous Goods Code lays down basic principles for transporting hazardous chemicals. Detailed recommendations for individual substances and a number of recommendations for good practice are included in the classes dealing with such substances. A general index of technical names has also been compiled. This index should always be consulted when attempting to locate the appropriate procedures to be used when shipping any substance or article.

Permissible Exposure Limit: Table Z-1 Ceiling value: 5 mg/cu m. /Manganese cmpd (as Mn)/

Recommended Exposure Limit: 10 Hr Time-Weighted Avg: 1 mg/cu m. /Manganese compounds and fume (as Mn)/|Recommended Exposure Limit: 15 Min Short-Term Exposure Limit: 3 mg/cu m. /Manganese compounds and fume (as Mn)/

Listed as a hazardous air pollutant (HAP) generally known or suspected to cause serious health problems. The Clean Air Act, as amended in 1990, directs EPA to set standards requiring major sources to sharply reduce routine emissions of toxic pollutants. EPA is required to establish and phase in specific performance based standards for all air emission sources that emit one or more of the listed pollutants. Calcium permanganate is included on this list.|... Substances for which a Federal Register notice has been published that included consideration of the serious health effects, including cancer, form ambient air exposure to the substance. Manganese (50 FR 32627; Aug. 13, 1985) is included on this list. /Manganese/

Toxicity

moderately toxic

Drug Information

MANGANOUS ION RESULTING FROM REDN OF PERMANGANATE IS ASTRINGENT, & THIS AIDS IN SUPPRESSION OF INFLAMMATION. ... THEIR FORMER EXTENSIVE LOCAL APPLICATION IN TREATMENT OF URETHRITIS HAS BECOME OBSOLETE. /PERMANGANATES/

VET: PERMANGANATE SOLN DO NOT PENETRATE DEEPLY & HAVE ONLY SUPERFICIAL ACTION. /PERMANGANATES/

Excerpt from ERG Guide 140 [Oxidizers]: Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause pollution. (ERG, 2016)

Excerpt from ERG Guide 140 [Oxidizers]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. Contaminated clothing may be a fire risk when dry. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. Keep victim calm and warm. (ERG, 2016)

Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . /Manganese and related compounds/|Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious or in severe respiratory distress. Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start an IV with D5W /SRP: "To keep open", minimal flow rate/. Use lactated Ringer's if signs of hypovolemia are present. Consider drug therapy for pulmonary edema ... . For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors for hypotension with a normal fluid volume. Watch for signs of fluid overload ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Manganese and related compounds/

Calcium permanganate Use and Manufacturing

Methods of Manufacturing

Prepd from potassium permanganate and calcium chloride: British patent 624,885 (1949 to Boots Pure Drug Company and T Hagyard); from aluminum permanganate and calcium oxide: Jaskowiak, US patent 2,504,130 (1950 to Carus Chemical).

Uses

Antiseptic, disinfectant, deodorizer; with CaF2 as binder for welding electrode coatings and fluxes.

Grades: technical; pure /Calcium permanganate tetrahydrate/

Computed Properties

Molecular Weight:277.95
Hydrogen Bond Acceptor Count:8
Exact Mass:277.797994
Monoisotopic Mass:277.797994
Topological Polar Surface Area:149
Heavy Atom Count:11
Complexity:95.8
Covalently-Bonded Unit Count:3
Compound Is Canonicalized:Yes

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.