    Carbamic acid,N,N-dimethyl-,3-methyl-1-phenyl-1H-pyrazol-5-yl ester;Carbamic acid,dimethyl-,3-methyl-1-phenylpyrazol-5-yl ester;Carbamic acid,dimethyl-,3-methyl-1-phenyl-1H-pyrazol-5-yl ester;G 22008;3-Methyl-1-phenylpyrazol-5-yl dimethylcarbamate;Pyrolan;NSC 404297;(5-Methyl-2-phenylpyrazol-3-yl) N,N-dimethylcarbamate

Description

Crystalline solid. Soluble in water and fats.


Pyrolan is a crystalline solid. (NTP, 1992)


Pyrolan is a crystalline solid. (NTP, 1992)

Pyrolan Basic Attributes

245.27700

245.28

868K72C292

404297

2588

DTXSID6042361

Characteristics

47.36000

2.24110

Pyrolan is a crystalline solid. (NTP, 1992)

1.15g/cm3

50 °C

160-162 °C

178.7ºC

1.573

1.996g/L(temperature not stated)

LD50 orally in rats: 62 mg/kg (Schafer)

Water soluble.

Azo, Diazo, Azido, Hydrazine, and Azide Compounds

Explosive

PYROLAN is a carbamate ester. Carbamates are chemically similar to, but more reactive than amides. Like amides they form polymers such as polyurethane resins. Carbamates are incompatible with strong acids and bases, and especially incompatible with strong reducing agents such as hydrides. Flammable gaseous hydrogen is produced by the combination of active metals or nitrides with carbamates. Strongly oxidizing acids, peroxides, and hydroperoxides are incompatible with carbamates.

Safety Information

III

6.1(b)

UN 2757

S24-S26-S39

Stability Incompatible with strong oxidizing agents.

Flash point data for this chemical are not available; however, it is probably combustible. (NTP, 1992)

Fires involving this material can be controlled with a dry chemical, carbon dioxide or Halon extinguisher. (NTP, 1992)

Excerpt from ERG Guide 151 [Substances - Toxic (Non-combustible)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)

SMALL SPILLS AND LEAKAGE: If you spill this chemical, you should dampen the solid spill material with water, then transfer the dampened material to a suitable container. Use absorbent paper dampened with water to pick up any remaining material. Seal your contaminated clothing and the absorbent paper in a vapor-tight plastic bag for eventual disposal. Wash all contaminated surfaces with a soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned. STORAGE PRECAUTIONS: You should store this material under ambient temperatures. (NTP, 1992)

MINIMUM PROTECTIVE CLOTHING: If Tyvek-type disposable protective clothing is not worn during handling of this chemical, wear disposable Tyvek-type sleeves taped to your gloves. RECOMMENDED RESPIRATOR: Where the neat test chemical is weighed and diluted, wear a NIOSH-approved half face respirator equipped with a combination filter cartridge, i.e. organic vapor/acid gas/HEPA (specific for organic vapors, HCl, acid gas, SO2 and a high efficiency particulate filter). (NTP, 1992)

Drug Information

ACUTE/CHRONIC HAZARDS: This compound is a reversible CHOLINESTERASE INHIBITOR. When heated to decomposition it emits toxic fumes of nitrogen oxides. (NTP, 1992)

EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop. SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. IMMEDIATELY call a hospital or poison control center even if no symptoms (such as redness or irritation) develop. IMMEDIATELY transport the victim to a hospital for treatment after washing the affected areas. INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. IMMEDIATELY call a physician and be prepared to transport the victim to a hospital even if no symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing. INGESTION: CHOLINESTERASE INHIBITORS ARE EXTREMELY TOXIC AND FAST-ACTING POISONS. IMMEDIATELY call a hospital of poison control center and transport the victim to a hospital. Atropine is an antidote for cholinesterase inhibitors but should only be administered by properly trained personnel. In the absence of this option and if the victim is conscious and not convulsing, it may be worth considering the risk of inducing vomiting, even though the induction of vomiting is not usually recommended outside of a physician's care. Ipecac syrup or salt water may be used to induce vomiting in such an emergency. If the victim is convulsing or unconscious, do not give anything by mouth, assure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. IMMEDIATELY transport the victim to a hospital. (NTP, 1992)

dimethyl 5-(3-methyl-1-phenyl-pyrazolyl)carbamate

Pyrolan Use and Manufacturing

Insecticide.

Computed Properties

Molecular Weight:245.28
XLogP3:2.4
Hydrogen Bond Acceptor Count:3
Rotatable Bond Count:3
Exact Mass:245.116426730
Monoisotopic Mass:245.116426730
Topological Polar Surface Area:47.4
Heavy Atom Count:18
Complexity:290
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes

Scan the QR Code to Share

Feedback & Suggestions
Send Message

Thank you for your feedback. If you require further assistance, please contact us by email at info@echemi.com or call us at +86-532-55729510.