Boric acid (H3BO3) tri-2-propen-1-yl ester
-
Boric acid (H3BO3) tri-2-propen-1-yl ester
structure -
-
CAS No:
1693-71-6
-
Formula:
C9H15BO3
-
Chemical Name:
Boric acid (H3BO3) tri-2-propen-1-yl ester
-
Synonyms:
Boric acid (H3BO3),tri-2-propen-1-yl ester;Boric acid (H3BO3),triallyl ester;Boric acid (H3BO3),tri-2-propenyl ester;Allyl borate;Boric acid (H3BO3) tri-2-propen-1-yl ester;Allyl borate ((C3H5O)3B);Triallyl borate;Triallyloxyborane;Tris(allyloxy)borane;NSC 65653;Trisallyl borate
-
CAS No:
Description
BORON ALLYLOXIDE is a colorless liquid. BORON ALLYLOXIDE is insoluble in water and weigh, less than water. Contact with the material may cause mild irritation to skin, eyes, and mucous membranes. BORON ALLYLOXIDE may be slightly toxic by ingestion. BORON ALLYLOXIDE is used to make other chemicals.
Triallyl borate is a colorless liquid. It is insoluble in water and weigh, less than water. Contact with the material may cause mild irritation to skin, eyes, and mucous membranes. It may be slightly toxic by ingestion. It is used to make other chemicals.
Triallyl borate is a colorless liquid. It is insoluble in water and weigh, less than water. Contact with the material may cause mild irritation to skin, eyes, and mucous membranes. It may be slightly toxic by ingestion. It is used to make other chemicals.
Boric acid (H3BO3) tri-2-propen-1-yl ester Basic Attributes
182.02
182.02
216-897-9
65653
2609
DTXSID4061886
2920909090
Characteristics
27.7
1.57910
Triallyl borate is a colorless liquid. It is insoluble in water and weigh, less than water. Contact with the material may cause mild irritation to skin, eyes, and mucous membranes. It may be slightly toxic by ingestion. It is used to make other chemicals.
0.919 g/cm3
72 °C @ Press: 12 Torr
31°C
1.427
Insoluble in water.
2.46mmHg at 25°C
Open flames are flammable; boron fumes are emitted from the fire
Insoluble in water.
Esters, Sulfate Esters, Phosphate Esters, Thiophosphate Esters, and Borate Esters
Borates, such as TRIALLYL BORATE, behave similarly to esters in that they react with acids to liberate heat along with alcohols and acids. Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products. Heat is also generated by the interaction of esters with caustic solutions. Flammable hydrogen is generated by mixing esters/borates with alkali metals and hydrides.
Safety Information
III
6.1(b)
1993
10-36/37/38
26-36/37/39
The warehouse is ventilated, low temperature and dry; stored and transported separately from food and oxidants
P210, P233, P240, P241, P242, P243, P261, P264, P270, P271, P280, P301+P312, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P312, P321, P330, P332+P313, P337+P313, P362, P370+P378, P403+P233, P403+P235, P405, P501
H226
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Combustible material: may burn but does not ignite readily. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapors may travel to source of ignition and flash back. Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water. (ERG, 2016)
|Warning|H226 (100%): Flammable liquid and vapor [Warning Flammable liquids]|P210, P233, P240, P241, P242, P243, P261, P264, P270, P271, P280, P301+P312, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P312, P321, P330, P332+P313, P337+P313, P362, P370+P378, P403+P233, P403+P235, P405, and P501|The GHS information provided by 1 company from 1 notification to the ECHA C&L Inventory.
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Note: Most foams will react with the material and release corrosive/toxic gases. SMALL FIRE: CO2, dry chemical, dry sand, alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam. FOR CHLOROSILANES, DO NOT USE WATER; use AFFF alcohol-resistant medium-expansion foam. Move containers from fire area if you can do it without risk. Use water spray or fog; do not use straight streams. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Do not get water inside containers. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2016)
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. SPILL: Increase, in the downwind direction, as necessary, the isolation distance shown above. FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. FOR CHLOROSILANES, use AFFF alcohol-resistant medium-expansion foam to reduce vapors. DO NOT GET WATER on spilled substance or inside containers. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas. SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2016)
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible. (ERG, 2016)
Drug Information
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death. Contact with molten substance may cause severe burns to skin and eyes. Reaction with water or moist air will release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause pollution. (ERG, 2016)
Excerpt from ERG Guide 156 [Substances - Toxic and/or Corrosive (Combustible / Water-Sensitive)]: Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves. Move victim to fresh air. Call 911 or emergency medical service. Give artificial respiration if victim is not breathing. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Administer oxygen if breathing is difficult. Remove and isolate contaminated clothing and shoes. In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes. For minor skin contact, avoid spreading material on unaffected skin. Keep victim calm and warm. Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed. (ERG, 2016)
Boric acid (H3BO3) tri-2-propen-1-yl ester Use and Manufacturing
Boric acid (H3BO3), tri-2-propen-1-yl ester: ACTIVE
Computed Properties
Molecular Weight:182.03
Hydrogen Bond Acceptor Count:3
Rotatable Bond Count:9
Exact Mass:182.1114245
Monoisotopic Mass:182.1114245
Topological Polar Surface Area:27.7
Heavy Atom Count:13
Complexity:130
Covalently-Bonded Unit Count:1
Compound Is Canonicalized:Yes
Learn More Other Chemicals
-
3-CYCLOPROPYL-2-METHYL-3-OXO-PROPIONIC ACID ETHYL ESTER
21741-37-7
-
CYCLOPENTYL-CARBAMIC ACID PHENYL ESTER
58713-31-8
-
2'-Deoxy-N-trimethylsilyl-3'-O-trimethylsilylcytidine 5'-phosphoric acid bis(trimethylsilyl) ester
32645-72-0
-
4,6-Dichloro-1H-indole-2,3-dicarboxylic acid diethyl ester Formula
146012-24-0
-
2-[(2,6-Dichlorophenyl)sulfonyl]acetic acid ethyl ester Formula
1154228-17-7
-
Dibenzoic acid 2-ethylhexamethylene ester Formula
25724-54-3
-
1,4-DIBENZYL-7-PHENYL-6-THIOXO-1,4,7-TRIAZA-SPIRO[4.4]NON-8-ENE-9-CARBOXYLIC ACID ETHYL ESTER Structure
885722-38-3
-
4,5-Dichloro-8-methylquinoline-3-carboxylic acid ethyl ester Structure
1019462-72-6
-
What is 3-(2,6-DICHLORO-PHENYL)-5-ISOPROPYL-ISOXAZOLE-4-CARBOXYLIC ACID METHYL ESTER
278597-28-7
-
What is 3-(β-D-Glucopyranosyloxy)-2-hydroxybenzoic acid 3-(1,3-dihydro-3-oxoisobenzofuran-1-yl)propyl ester
94617-34-2
Boric acid (H3BO3) tri-2-propen-1-yl ester
SDSRequest for Quotation